Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -70,7 +70,7 @@ 70 70 71 71 To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection": 72 72 73 -[[image:1732212357972-295.png]] 73 +[[Overvoltage protection settings>>image:1732212357972-295.png||data-xwiki-image-style-alignment="center" height="218" width="338"]] 74 74 75 75 In this section: 76 76 ... ... @@ -103,6 +103,7 @@ 103 103 104 104 To change the battery protection parameters from low temperature, select the menu "Protections → Low temperature protection": 105 105 106 +[[Low temperature protection settings>>image:1732213953083-955.png||data-xwiki-image-style-alignment="center" height="237" width="338"]] 106 106 107 107 In this section: 108 108 ... ... @@ -137,6 +137,7 @@ 137 137 138 138 To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection": 139 139 141 +[[image:1732213990755-759.png]] 140 140 141 141 In this section: 142 142 ... ... @@ -823,3 +823,45 @@ 823 823 ))) 824 824 825 825 == 3.6.31 Fault simulation == 828 + 829 +The board provides the ability to manually generate error flags bypassing the protection algorithms. This functionality is intended for commissioning. 830 + 831 +To simulate battery and BMS errors, select the menu "Protections → Fault simulation": 832 + 833 + 834 +In this section: 835 + 836 +* Overcurrent; 837 +* Undervoltage; 838 +* Overvoltage; 839 +* Low CH temperature; 840 +* Low DCH temperature; 841 +* High CH temperature; 842 +* High DCH temperature; 843 +* Battery cover error; 844 +* High humidity; 845 +* Water; 846 +* Current sensor error; 847 +* Short circuit; 848 +* Contactor high temperature; 849 +* Unallowable charging; 850 +* Stuck contactor; 851 +* CH contactor feedback error; 852 +* DCH contactor feedback error; 853 +* PCH contactor feedback error; 854 +* CH/DCH contactor feedback error; 855 +* Main contactor feedback error; 856 +* CH contactor cycles error; 857 +* DCH contactor cycles error; 858 +* Logic high temperature; 859 +* Logic offline; 860 +* Cell count error; 861 +* Logic count error; 862 +* Insulation error; 863 +* Critical error; 864 +* Low SOC; 865 +* High charging current; 866 +* Heater; 867 +* Cooler. 868 + 869 +To simulate errors, set the necessary flags and click on the "Save" button.
- 1732213953083-955.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.0 KB - Content
- 1732213990755-759.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.7 KB - Content