Changes for page 3.6 Battery protection

Last modified by Admin on 2025/04/09 12:25

From version 4.24
edited by Admin
on 2024/11/21 18:29
Change comment: There is no comment for this version
To version 4.23
edited by Admin
on 2024/11/21 18:28
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -757,38 +757,10 @@
757 757  
758 758  * the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time.
759 759  
760 -(% class="box infomessage" %)
761 -(((
762 762  If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output.
763 -)))
764 764  
765 765  == 3.6.29 Heater (AUX) control ==
766 766  
767 -To change the parameters of the heater control algorithm, select the menu "Protections → Heater (AUX) control":
768 -
769 -
770 -In this section:
771 -
772 -* Enable – a flag to enable heater control;
773 -* Minimum cell temperature, °C;
774 -* Tolerant cell temperature, °C;
775 -* Delay before setting the signal, second;
776 -* Delay before clearing the signal, second;
777 -* Lock the signal until the device is reset;
778 -* Switch off the heater relay on errors (Undervoltage, Overcurrent, High temperature, Short circuit or Critical error).
779 -
780 -As a result of operating the heating algorithm, the “Heater (AUX)” signal is generated.
781 -
782 -Conditions of signal generation:
783 -
784 -* The minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before setting the signal” time.
785 -
786 -Conditions for clearing the signal:
787 -
788 -* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time.
789 -
790 -If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output.
791 -
792 792  == 3.6.30 Cooler control ==
793 793  
794 794  == 3.6.31 Fault simulation ==