Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 9 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -70,7 +70,7 @@ 70 70 71 71 To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection": 72 72 73 -[[image:1732212357972-295.png]] 73 +[[Overvoltage protection settings>>image:1732212357972-295.png||data-xwiki-image-style-alignment="center" height="218" width="338"]] 74 74 75 75 In this section: 76 76 ... ... @@ -103,6 +103,7 @@ 103 103 104 104 To change the battery protection parameters from low temperature, select the menu "Protections → Low temperature protection": 105 105 106 +[[Low temperature protection settings>>image:1732213953083-955.png||data-xwiki-image-style-alignment="center" height="237" width="338"]] 106 106 107 107 In this section: 108 108 ... ... @@ -137,6 +137,7 @@ 137 137 138 138 To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection": 139 139 141 +[[High temperature protection settings>>image:1732213990755-759.png||data-xwiki-image-style-alignment="center" height="258" width="370"]] 140 140 141 141 In this section: 142 142 ... ... @@ -169,6 +169,8 @@ 169 169 170 170 To change the protection parameters from opening the battery cover, select the menu "Protections → Battery cover protection": 171 171 174 +[[Battery cover protection settings>>image:1732214030014-281.png||data-xwiki-image-style-alignment="center" height="155" width="334"]] 175 + 172 172 In this section: 173 173 174 174 * Enable – a flag to enable the protection; ... ... @@ -197,12 +197,13 @@ 197 197 198 198 To change the protection parameters of the battery from high humidity, select the menu "Protections → High humidity protection": 199 199 204 +[[High humidity protection settings>>image:1732214076060-358.png||data-xwiki-image-style-alignment="center" height="185" width="321"]] 200 200 201 201 In this section: 202 202 203 203 * Enable – a flag to enable the protection; 204 -* Maximum humidty, RH%; 205 -* Tolerant humidty, RH%; 209 +* Maximum humidity, RH%; 210 +* Tolerant humidity, RH%; 206 206 * Delay before setting the error, second; 207 207 * Delay before clearing the error, second; 208 208 * Lock the error until the device is reset. ... ... @@ -226,6 +226,7 @@ 226 226 227 227 To change the protection parameters of the battery from water, select the menu "Protections → Water protection": 228 228 234 +[[Water protection settings>>image:1732214111990-184.png||data-xwiki-image-style-alignment="center" height="199" width="340"]] 229 229 230 230 In this section: 231 231 ... ... @@ -257,6 +257,7 @@ 257 257 258 258 To change the test parameters of the current sensor connection circuits, select the menu "Protections → Current sensor error": 259 259 266 +[[Current sensor error settings>>image:1732214146724-132.png||data-xwiki-image-style-alignment="center" height="438" width="365"]] 260 260 261 261 In this section: 262 262 ... ... @@ -290,6 +290,7 @@ 290 290 291 291 To change the protection parameters from short circuit, select the menu "Protections → Short circuit protection": 292 292 300 +[[Short circuit protection settings>>image:1732214207026-822.png||data-xwiki-image-style-alignment="center" height="528" width="371"]] 293 293 294 294 In this section: 295 295 ... ... @@ -323,6 +323,7 @@ 323 323 324 324 To change the overheating protection parameters of power contactors, select the menu "Protections → Contactor high temperature protection": 325 325 334 +[[image:1732214237851-405.png]] 326 326 327 327 In this section: 328 328 ... ... @@ -764,7 +764,7 @@ 764 764 765 765 == 3.6.29 Heater (AUX) control == 766 766 767 -To change the parameters of the heater control algorithm, select the menu "Protections → Heater (AUX) control": 776 +To change the parameters of the auxiliary heater control algorithm, select the menu "Protections → Heater (AUX) control": 768 768 769 769 770 770 In this section: ... ... @@ -787,8 +787,81 @@ 787 787 788 788 * the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 789 789 790 -If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 799 +(% class="box infomessage" %) 800 +((( 801 +If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output. 802 +))) 791 791 792 792 == 3.6.30 Cooler control == 793 793 806 +To change the parameters of the cooler control algorithm, select the menu "Protections → Cooler control": 807 + 808 + 809 +In this section: 810 + 811 +* Enable – a flag to enable cooler control; 812 +* Maximum cell temperature, °C; 813 +* Tolerant cell temperature, °C; 814 +* Delay before setting the signal, second; 815 +* Delay before clearing the signal, second; 816 +* Lock the signal until the device is reset; 817 +* Switch off the cooler relay on errors (Undervoltage, Overcurrent, Low temperature, Short circuit or Critical error). 818 + 819 +As a result of operating the cooling algorithm, the "Cooler" signal is generated. 820 + 821 +Conditions of signal generation: 822 + 823 +* the maximum temperature among all cells of the battery is greater than the “Maximum cell temperature” value during the “Delay before setting the signal” time. 824 + 825 +Conditions for clearing the signal: 826 + 827 +* the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 828 + 829 +(% class="box infomessage" %) 830 +((( 831 +If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output. 832 +))) 833 + 794 794 == 3.6.31 Fault simulation == 835 + 836 +The board provides the ability to manually generate error flags bypassing the protection algorithms. This functionality is intended for commissioning. 837 + 838 +To simulate battery and BMS errors, select the menu "Protections → Fault simulation": 839 + 840 + 841 +In this section: 842 + 843 +* Overcurrent; 844 +* Undervoltage; 845 +* Overvoltage; 846 +* Low CH temperature; 847 +* Low DCH temperature; 848 +* High CH temperature; 849 +* High DCH temperature; 850 +* Battery cover error; 851 +* High humidity; 852 +* Water; 853 +* Current sensor error; 854 +* Short circuit; 855 +* Contactor high temperature; 856 +* Unallowable charging; 857 +* Stuck contactor; 858 +* CH contactor feedback error; 859 +* DCH contactor feedback error; 860 +* PCH contactor feedback error; 861 +* CH/DCH contactor feedback error; 862 +* Main contactor feedback error; 863 +* CH contactor cycles error; 864 +* DCH contactor cycles error; 865 +* Logic high temperature; 866 +* Logic offline; 867 +* Cell count error; 868 +* Logic count error; 869 +* Insulation error; 870 +* Critical error; 871 +* Low SOC; 872 +* High charging current; 873 +* Heater; 874 +* Cooler. 875 + 876 +To simulate errors, set the necessary flags and click on the "Save" button.
- 1732213953083-955.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.0 KB - Content
- 1732213990755-759.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.7 KB - Content
- 1732214030014-281.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.6 KB - Content
- 1732214076060-358.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.1 KB - Content
- 1732214111990-184.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.1 KB - Content
- 1732214146724-132.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.8 KB - Content
- 1732214183037-761.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.7 KB - Content
- 1732214207026-822.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.8 KB - Content
- 1732214237851-405.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.6 KB - Content