Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -70,7 +70,7 @@ 70 70 71 71 To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection": 72 72 73 -[[image:1732212357972-295.png]] 73 +[[Overvoltage protection settings>>image:1732212357972-295.png||data-xwiki-image-style-alignment="center" height="218" width="338"]] 74 74 75 75 In this section: 76 76 ... ... @@ -103,6 +103,7 @@ 103 103 104 104 To change the battery protection parameters from low temperature, select the menu "Protections → Low temperature protection": 105 105 106 +[[Low temperature protection settings>>image:1732213953083-955.png||data-xwiki-image-style-alignment="center" height="237" width="338"]] 106 106 107 107 In this section: 108 108 ... ... @@ -137,6 +137,7 @@ 137 137 138 138 To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection": 139 139 141 +[[High temperature protection settings>>image:1732213990755-759.png||data-xwiki-image-style-alignment="center" height="258" width="370"]] 140 140 141 141 In this section: 142 142 ... ... @@ -169,6 +169,8 @@ 169 169 170 170 To change the protection parameters from opening the battery cover, select the menu "Protections → Battery cover protection": 171 171 174 +[[Battery cover protection settings>>image:1732214030014-281.png||data-xwiki-image-style-alignment="center" height="155" width="334"]] 175 + 172 172 In this section: 173 173 174 174 * Enable – a flag to enable the protection; ... ... @@ -757,10 +757,111 @@ 757 757 758 758 * the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 759 759 764 +(% class="box infomessage" %) 765 +((( 760 760 If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 767 +))) 761 761 762 762 == 3.6.29 Heater (AUX) control == 763 763 771 +To change the parameters of the auxiliary heater control algorithm, select the menu "Protections → Heater (AUX) control": 772 + 773 + 774 +In this section: 775 + 776 +* Enable – a flag to enable heater control; 777 +* Minimum cell temperature, °C; 778 +* Tolerant cell temperature, °C; 779 +* Delay before setting the signal, second; 780 +* Delay before clearing the signal, second; 781 +* Lock the signal until the device is reset; 782 +* Switch off the heater relay on errors (Undervoltage, Overcurrent, High temperature, Short circuit or Critical error). 783 + 784 +As a result of operating the heating algorithm, the “Heater (AUX)” signal is generated. 785 + 786 +Conditions of signal generation: 787 + 788 +* The minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before setting the signal” time. 789 + 790 +Conditions for clearing the signal: 791 + 792 +* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 793 + 794 +(% class="box infomessage" %) 795 +((( 796 +If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output. 797 +))) 798 + 764 764 == 3.6.30 Cooler control == 765 765 801 +To change the parameters of the cooler control algorithm, select the menu "Protections → Cooler control": 802 + 803 + 804 +In this section: 805 + 806 +* Enable – a flag to enable cooler control; 807 +* Maximum cell temperature, °C; 808 +* Tolerant cell temperature, °C; 809 +* Delay before setting the signal, second; 810 +* Delay before clearing the signal, second; 811 +* Lock the signal until the device is reset; 812 +* Switch off the cooler relay on errors (Undervoltage, Overcurrent, Low temperature, Short circuit or Critical error). 813 + 814 +As a result of operating the cooling algorithm, the "Cooler" signal is generated. 815 + 816 +Conditions of signal generation: 817 + 818 +* the maximum temperature among all cells of the battery is greater than the “Maximum cell temperature” value during the “Delay before setting the signal” time. 819 + 820 +Conditions for clearing the signal: 821 + 822 +* the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 823 + 824 +(% class="box infomessage" %) 825 +((( 826 +If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output. 827 +))) 828 + 766 766 == 3.6.31 Fault simulation == 830 + 831 +The board provides the ability to manually generate error flags bypassing the protection algorithms. This functionality is intended for commissioning. 832 + 833 +To simulate battery and BMS errors, select the menu "Protections → Fault simulation": 834 + 835 + 836 +In this section: 837 + 838 +* Overcurrent; 839 +* Undervoltage; 840 +* Overvoltage; 841 +* Low CH temperature; 842 +* Low DCH temperature; 843 +* High CH temperature; 844 +* High DCH temperature; 845 +* Battery cover error; 846 +* High humidity; 847 +* Water; 848 +* Current sensor error; 849 +* Short circuit; 850 +* Contactor high temperature; 851 +* Unallowable charging; 852 +* Stuck contactor; 853 +* CH contactor feedback error; 854 +* DCH contactor feedback error; 855 +* PCH contactor feedback error; 856 +* CH/DCH contactor feedback error; 857 +* Main contactor feedback error; 858 +* CH contactor cycles error; 859 +* DCH contactor cycles error; 860 +* Logic high temperature; 861 +* Logic offline; 862 +* Cell count error; 863 +* Logic count error; 864 +* Insulation error; 865 +* Critical error; 866 +* Low SOC; 867 +* High charging current; 868 +* Heater; 869 +* Cooler. 870 + 871 +To simulate errors, set the necessary flags and click on the "Save" button.
- 1732213953083-955.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.0 KB - Content
- 1732213990755-759.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.7 KB - Content
- 1732214030014-281.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.6 KB - Content
- 1732214076060-358.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.1 KB - Content