Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -757,10 +757,111 @@ 757 757 758 758 * the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 759 759 760 +(% class="box infomessage" %) 761 +((( 760 760 If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 763 +))) 761 761 762 762 == 3.6.29 Heater (AUX) control == 763 763 767 +To change the parameters of the auxiliary heater control algorithm, select the menu "Protections → Heater (AUX) control": 768 + 769 + 770 +In this section: 771 + 772 +* Enable – a flag to enable heater control; 773 +* Minimum cell temperature, °C; 774 +* Tolerant cell temperature, °C; 775 +* Delay before setting the signal, second; 776 +* Delay before clearing the signal, second; 777 +* Lock the signal until the device is reset; 778 +* Switch off the heater relay on errors (Undervoltage, Overcurrent, High temperature, Short circuit or Critical error). 779 + 780 +As a result of operating the heating algorithm, the “Heater (AUX)” signal is generated. 781 + 782 +Conditions of signal generation: 783 + 784 +* The minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before setting the signal” time. 785 + 786 +Conditions for clearing the signal: 787 + 788 +* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 789 + 790 +(% class="box infomessage" %) 791 +((( 792 +If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output. 793 +))) 794 + 764 764 == 3.6.30 Cooler control == 765 765 797 +To change the parameters of the cooler control algorithm, select the menu "Protections → Cooler control": 798 + 799 + 800 +In this section: 801 + 802 +* Enable – a flag to enable cooler control; 803 +* Maximum cell temperature, °C; 804 +* Tolerant cell temperature, °C; 805 +* Delay before setting the signal, second; 806 +* Delay before clearing the signal, second; 807 +* Lock the signal until the device is reset; 808 +* Switch off the cooler relay on errors (Undervoltage, Overcurrent, Low temperature, Short circuit or Critical error). 809 + 810 +As a result of operating the cooling algorithm, the "Cooler" signal is generated. 811 + 812 +Conditions of signal generation: 813 + 814 +* the maximum temperature among all cells of the battery is greater than the “Maximum cell temperature” value during the “Delay before setting the signal” time. 815 + 816 +Conditions for clearing the signal: 817 + 818 +* the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 819 + 820 +(% class="box infomessage" %) 821 +((( 822 +If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output. 823 +))) 824 + 766 766 == 3.6.31 Fault simulation == 826 + 827 +The board provides the ability to manually generate error flags bypassing the protection algorithms. This functionality is intended for commissioning. 828 + 829 +To simulate battery and BMS errors, select the menu "Protections → Fault simulation": 830 + 831 + 832 +In this section: 833 + 834 +* Overcurrent; 835 +* Undervoltage; 836 +* Overvoltage; 837 +* Low CH temperature; 838 +* Low DCH temperature; 839 +* High CH temperature; 840 +* High DCH temperature; 841 +* Battery cover error; 842 +* High humidity; 843 +* Water; 844 +* Current sensor error; 845 +* Short circuit; 846 +* Contactor high temperature; 847 +* Unallowable charging; 848 +* Stuck contactor; 849 +* CH contactor feedback error; 850 +* DCH contactor feedback error; 851 +* PCH contactor feedback error; 852 +* CH/DCH contactor feedback error; 853 +* Main contactor feedback error; 854 +* CH contactor cycles error; 855 +* DCH contactor cycles error; 856 +* Logic high temperature; 857 +* Logic offline; 858 +* Cell count error; 859 +* Logic count error; 860 +* Insulation error; 861 +* Critical error; 862 +* Low SOC; 863 +* High charging current; 864 +* Heater; 865 +* Cooler. 866 + 867 +To simulate errors, set the necessary flags and click on the "Save" button.
- 1732213953083-955.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.0 KB - Content
- 1732213990755-759.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.7 KB - Content