757 757  
758 758  * the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time.
759 759  
760 +(% class="box infomessage" %)
761 +(((
760 760  If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output.
763 +)))
761 761  
762 762  == 3.6.29 Heater (AUX) control ==
763 763  
767 +To change the parameters of the heater control algorithm, select the menu "Protections → Heater (AUX) control":
768 +
769 +
770 +In this section:
771 +
772 +* Enable – a flag to enable heater control;
773 +* Minimum cell temperature, °C;
774 +* Tolerant cell temperature, °C;
775 +* Delay before setting the signal, second;
776 +* Delay before clearing the signal, second;
777 +* Lock the signal until the device is reset;
778 +* Switch off the heater relay on errors (Undervoltage, Overcurrent, High temperature, Short circuit or Critical error).
779 +
780 +As a result of operating the heating algorithm, the “Heater (AUX)” signal is generated.
781 +
782 +Conditions of signal generation:
783 +
784 +* The minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before setting the signal” time.
785 +
786 +Conditions for clearing the signal:
787 +
788 +* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time.
789 +
790 +If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output.
791 +
764 764  == 3.6.30 Cooler control ==
765 765  