Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -706,17 +706,89 @@ 706 706 707 707 * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 708 708 709 -(% class="box infomessage" %) 710 -((( 711 -The "Low SOC signal" is indicative and can be linked to any discrete output of the board. 712 -))) 709 +The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board. 713 713 714 714 == 3.6.27 High charging current signal == 715 715 713 +To change the parameters of the generation high-current signal, select the menu "Protections → High charging current signal": 714 + 715 + 716 +In this section: 717 + 718 +* Enable – a flag to enable signal generation; 719 +* Maximum charging current, А; 720 +* Tolerant charging current, А; 721 +* Delay before setting the signal, second; 722 +* Delay before clearing the signal, second; 723 +* Lock the signal until the device is reset. 724 + 725 +Signal generation conditions: 726 + 727 +* the measured current is greater than the “Maximum charging current” value during the “Delay before setting the signal” time. 728 + 729 +Conditions for clearing the signal: 730 + 731 +* the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 732 + 733 +The "High charging current" signal is //indicative //and can be linked to any discrete output of the board. 734 + 716 716 == 3.6.28 Heater control == 717 717 737 +To change the parameters of the heater control algorithm, select the menu "Protections → Heater control": 738 + 739 + 740 +In this section: 741 + 742 +* Enable – a flag to enable heater control; 743 +* Minimum cell temperature, °C; 744 +* Tolerant cell temperature, °C; 745 +* Delay before setting the signal, second; 746 +* Delay before clearing the signal, second; 747 +* Lock the signal until the device is reset; 748 +* Switch off the heater relay on errors (Undervoltage, Overcurrent, High temperature, Short circuit or Critical error). 749 + 750 +As a result of operating the heating algorithm, the “Heater” signal is generated. 751 + 752 +Conditions of signal generation: 753 + 754 +* The minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before setting the signal” time. 755 + 756 +Conditions for clearing the signal: 757 + 758 +* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 759 + 760 +(% class="box infomessage" %) 761 +((( 762 +If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 763 +))) 764 + 718 718 == 3.6.29 Heater (AUX) control == 719 719 767 +To change the parameters of the heater control algorithm, select the menu "Protections → Heater (AUX) control": 768 + 769 + 770 +In this section: 771 + 772 +* Enable – a flag to enable heater control; 773 +* Minimum cell temperature, °C; 774 +* Tolerant cell temperature, °C; 775 +* Delay before setting the signal, second; 776 +* Delay before clearing the signal, second; 777 +* Lock the signal until the device is reset; 778 +* Switch off the heater relay on errors (Undervoltage, Overcurrent, High temperature, Short circuit or Critical error). 779 + 780 +As a result of operating the heating algorithm, the “Heater (AUX)” signal is generated. 781 + 782 +Conditions of signal generation: 783 + 784 +* The minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before setting the signal” time. 785 + 786 +Conditions for clearing the signal: 787 + 788 +* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 789 + 790 +If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 791 + 720 720 == 3.6.30 Cooler control == 721 721 722 722 == 3.6.31 Fault simulation ==