Changes for page 3.6 Battery protection

Last modified by Admin on 2025/04/09 12:25

From version 4.22
edited by Admin
on 2024/11/21 18:27
Change comment: There is no comment for this version
To version 4.23
edited by Admin
on 2024/11/21 18:28
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -706,15 +706,59 @@
706 706  
707 707  * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time.
708 708  
709 -(% class="box infomessage" %)
710 -(((
711 -The "Low SOC signal" is indicative and can be linked to any discrete output of the board.
712 -)))
709 +The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board.
713 713  
714 714  == 3.6.27 High charging current signal ==
715 715  
713 +To change the parameters of the generation high-current signal, select the menu "Protections → High charging current signal":
714 +
715 +
716 +In this section:
717 +
718 +* Enable – a flag to enable signal generation;
719 +* Maximum charging current, А;
720 +* Tolerant charging current, А;
721 +* Delay before setting the signal, second;
722 +* Delay before clearing the signal, second;
723 +* Lock the signal until the device is reset.
724 +
725 +Signal generation conditions:
726 +
727 +* the measured current is greater than the “Maximum charging current” value during the “Delay before setting the signal” time.
728 +
729 +Conditions for clearing the signal:
730 +
731 +* the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time.
732 +
733 +The "High charging current" signal is //indicative //and can be linked to any discrete output of the board.
734 +
716 716  == 3.6.28 Heater control ==
717 717  
737 +To change the parameters of the heater control algorithm, select the menu "Protections → Heater control":
738 +
739 +
740 +In this section:
741 +
742 +* Enable – a flag to enable heater control;
743 +* Minimum cell temperature, °C;
744 +* Tolerant cell temperature, °C;
745 +* Delay before setting the signal, second;
746 +* Delay before clearing the signal, second;
747 +* Lock the signal until the device is reset;
748 +* Switch off the heater relay on errors (Undervoltage, Overcurrent, High temperature, Short circuit or Critical error).
749 +
750 +As a result of operating the heating algorithm, the “Heater” signal is generated.
751 +
752 +Conditions of signal generation:
753 +
754 +* The minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before setting the signal” time.
755 +
756 +Conditions for clearing the signal:
757 +
758 +* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time.
759 +
760 +If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output.
761 +
718 718  == 3.6.29 Heater (AUX) control ==
719 719  
720 720  == 3.6.30 Cooler control ==