Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 15 added, 0 removed)
- 1732213953083-955.png
- 1732213990755-759.png
- 1732214030014-281.png
- 1732214076060-358.png
- 1732214111990-184.png
- 1732214146724-132.png
- 1732214183037-761.png
- 1732214207026-822.png
- 1732214237851-405.png
- 1732214272022-547.png
- 1732214367207-318.png
- 1732214400721-274.png
- 1732214432750-543.png
- 1732214468462-541.png
- 1732214501360-654.png
Details
- Page properties
-
- Content
-
... ... @@ -70,7 +70,7 @@ 70 70 71 71 To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection": 72 72 73 -[[image:1732212357972-295.png]] 73 +[[Overvoltage protection settings>>image:1732212357972-295.png||data-xwiki-image-style-alignment="center" height="218" width="338"]] 74 74 75 75 In this section: 76 76 ... ... @@ -103,6 +103,7 @@ 103 103 104 104 To change the battery protection parameters from low temperature, select the menu "Protections → Low temperature protection": 105 105 106 +[[Low temperature protection settings>>image:1732213953083-955.png||data-xwiki-image-style-alignment="center" height="237" width="338"]] 106 106 107 107 In this section: 108 108 ... ... @@ -137,6 +137,7 @@ 137 137 138 138 To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection": 139 139 141 +[[High temperature protection settings>>image:1732213990755-759.png||data-xwiki-image-style-alignment="center" height="258" width="370"]] 140 140 141 141 In this section: 142 142 ... ... @@ -169,6 +169,8 @@ 169 169 170 170 To change the protection parameters from opening the battery cover, select the menu "Protections → Battery cover protection": 171 171 174 +[[Battery cover protection settings>>image:1732214030014-281.png||data-xwiki-image-style-alignment="center" height="155" width="334"]] 175 + 172 172 In this section: 173 173 174 174 * Enable – a flag to enable the protection; ... ... @@ -197,12 +197,13 @@ 197 197 198 198 To change the protection parameters of the battery from high humidity, select the menu "Protections → High humidity protection": 199 199 204 +[[High humidity protection settings>>image:1732214076060-358.png||data-xwiki-image-style-alignment="center" height="185" width="321"]] 200 200 201 201 In this section: 202 202 203 203 * Enable – a flag to enable the protection; 204 -* Maximum humidty, RH%; 205 -* Tolerant humidty, RH%; 209 +* Maximum humidity, RH%; 210 +* Tolerant humidity, RH%; 206 206 * Delay before setting the error, second; 207 207 * Delay before clearing the error, second; 208 208 * Lock the error until the device is reset. ... ... @@ -226,6 +226,7 @@ 226 226 227 227 To change the protection parameters of the battery from water, select the menu "Protections → Water protection": 228 228 234 +[[Water protection settings>>image:1732214111990-184.png||data-xwiki-image-style-alignment="center" height="199" width="340"]] 229 229 230 230 In this section: 231 231 ... ... @@ -257,6 +257,7 @@ 257 257 258 258 To change the test parameters of the current sensor connection circuits, select the menu "Protections → Current sensor error": 259 259 266 +[[Current sensor error settings>>image:1732214146724-132.png||data-xwiki-image-style-alignment="center" height="438" width="365"]] 260 260 261 261 In this section: 262 262 ... ... @@ -290,6 +290,7 @@ 290 290 291 291 To change the protection parameters from short circuit, select the menu "Protections → Short circuit protection": 292 292 300 +[[Short circuit protection settings>>image:1732214207026-822.png||data-xwiki-image-style-alignment="center" height="528" width="371"]] 293 293 294 294 In this section: 295 295 ... ... @@ -323,6 +323,7 @@ 323 323 324 324 To change the overheating protection parameters of power contactors, select the menu "Protections → Contactor high temperature protection": 325 325 334 +[[Contactor high temperature protection settings>>image:1732214237851-405.png||data-xwiki-image-style-alignment="center" height="234" width="336"]] 326 326 327 327 In this section: 328 328 ... ... @@ -356,6 +356,7 @@ 356 356 357 357 To change the parameters of the unallowable charging protection, select the menu "Protections → Unallowable charging protection": 358 358 368 +[[Unallowable charging protection settings>>image:1732214272022-547.png||data-xwiki-image-style-alignment="center" height="145" width="312"]] 359 359 360 360 In this section: 361 361 ... ... @@ -385,6 +385,7 @@ 385 385 386 386 To change the protection parameters against sticking, select the menu "Protections → Stuck contactor protection": 387 387 398 +[[Stuck contactor protection settings>>image:1732214367207-318.png||data-xwiki-image-style-alignment="center" height="152" width="331"]] 388 388 389 389 In this section: 390 390 ... ... @@ -405,6 +405,7 @@ 405 405 406 406 To change the contactor feedback check parameters, select the menu "Protections → Contactor feedback check": 407 407 419 +[[Contactor feedback check settings>>image:1732214400721-274.png||data-xwiki-image-style-alignment="center" height="150" width="323"]] 408 408 409 409 In this section: 410 410 ... ... @@ -423,6 +423,7 @@ 423 423 424 424 To change the protection parameters against high frequency switching of the charging contactor, select the menu "Protections → Charging contactor cycles protection": 425 425 438 +[[image:1732214432750-543.png]] 426 426 427 427 In this section: 428 428 ... ... @@ -706,17 +706,162 @@ 706 706 707 707 * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 708 708 709 -(% class="box infomessage" %) 710 -((( 711 -The "Low SOC signal" is indicative and can be linked to any discrete output of the board. 712 -))) 722 +The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board. 713 713 714 714 == 3.6.27 High charging current signal == 715 715 726 +To change the parameters of the generation high-current signal, select the menu "Protections → High charging current signal": 727 + 728 + 729 +In this section: 730 + 731 +* Enable – a flag to enable signal generation; 732 +* Maximum charging current, А; 733 +* Tolerant charging current, А; 734 +* Delay before setting the signal, second; 735 +* Delay before clearing the signal, second; 736 +* Lock the signal until the device is reset. 737 + 738 +Signal generation conditions: 739 + 740 +* the measured current is greater than the “Maximum charging current” value during the “Delay before setting the signal” time. 741 + 742 +Conditions for clearing the signal: 743 + 744 +* the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 745 + 746 +The "High charging current" signal is //indicative //and can be linked to any discrete output of the board. 747 + 716 716 == 3.6.28 Heater control == 717 717 750 +To change the parameters of the heater control algorithm, select the menu "Protections → Heater control": 751 + 752 + 753 +In this section: 754 + 755 +* Enable – a flag to enable heater control; 756 +* Minimum cell temperature, °C; 757 +* Tolerant cell temperature, °C; 758 +* Delay before setting the signal, second; 759 +* Delay before clearing the signal, second; 760 +* Lock the signal until the device is reset; 761 +* Switch off the heater relay on errors (Undervoltage, Overcurrent, High temperature, Short circuit or Critical error). 762 + 763 +As a result of operating the heating algorithm, the “Heater” signal is generated. 764 + 765 +Conditions of signal generation: 766 + 767 +* The minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before setting the signal” time. 768 + 769 +Conditions for clearing the signal: 770 + 771 +* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 772 + 773 +(% class="box infomessage" %) 774 +((( 775 +If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 776 +))) 777 + 718 718 == 3.6.29 Heater (AUX) control == 719 719 780 +To change the parameters of the auxiliary heater control algorithm, select the menu "Protections → Heater (AUX) control": 781 + 782 + 783 +In this section: 784 + 785 +* Enable – a flag to enable heater control; 786 +* Minimum cell temperature, °C; 787 +* Tolerant cell temperature, °C; 788 +* Delay before setting the signal, second; 789 +* Delay before clearing the signal, second; 790 +* Lock the signal until the device is reset; 791 +* Switch off the heater relay on errors (Undervoltage, Overcurrent, High temperature, Short circuit or Critical error). 792 + 793 +As a result of operating the heating algorithm, the “Heater (AUX)” signal is generated. 794 + 795 +Conditions of signal generation: 796 + 797 +* The minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before setting the signal” time. 798 + 799 +Conditions for clearing the signal: 800 + 801 +* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 802 + 803 +(% class="box infomessage" %) 804 +((( 805 +If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output. 806 +))) 807 + 720 720 == 3.6.30 Cooler control == 721 721 810 +To change the parameters of the cooler control algorithm, select the menu "Protections → Cooler control": 811 + 812 + 813 +In this section: 814 + 815 +* Enable – a flag to enable cooler control; 816 +* Maximum cell temperature, °C; 817 +* Tolerant cell temperature, °C; 818 +* Delay before setting the signal, second; 819 +* Delay before clearing the signal, second; 820 +* Lock the signal until the device is reset; 821 +* Switch off the cooler relay on errors (Undervoltage, Overcurrent, Low temperature, Short circuit or Critical error). 822 + 823 +As a result of operating the cooling algorithm, the "Cooler" signal is generated. 824 + 825 +Conditions of signal generation: 826 + 827 +* the maximum temperature among all cells of the battery is greater than the “Maximum cell temperature” value during the “Delay before setting the signal” time. 828 + 829 +Conditions for clearing the signal: 830 + 831 +* the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 832 + 833 +(% class="box infomessage" %) 834 +((( 835 +If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output. 836 +))) 837 + 722 722 == 3.6.31 Fault simulation == 839 + 840 +The board provides the ability to manually generate error flags bypassing the protection algorithms. This functionality is intended for commissioning. 841 + 842 +To simulate battery and BMS errors, select the menu "Protections → Fault simulation": 843 + 844 + 845 +In this section: 846 + 847 +* Overcurrent; 848 +* Undervoltage; 849 +* Overvoltage; 850 +* Low CH temperature; 851 +* Low DCH temperature; 852 +* High CH temperature; 853 +* High DCH temperature; 854 +* Battery cover error; 855 +* High humidity; 856 +* Water; 857 +* Current sensor error; 858 +* Short circuit; 859 +* Contactor high temperature; 860 +* Unallowable charging; 861 +* Stuck contactor; 862 +* CH contactor feedback error; 863 +* DCH contactor feedback error; 864 +* PCH contactor feedback error; 865 +* CH/DCH contactor feedback error; 866 +* Main contactor feedback error; 867 +* CH contactor cycles error; 868 +* DCH contactor cycles error; 869 +* Logic high temperature; 870 +* Logic offline; 871 +* Cell count error; 872 +* Logic count error; 873 +* Insulation error; 874 +* Critical error; 875 +* Low SOC; 876 +* High charging current; 877 +* Heater; 878 +* Cooler. 879 + 880 +To simulate errors, set the necessary flags and click on the "Save" button.
- 1732213953083-955.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.0 KB - Content
- 1732213990755-759.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.7 KB - Content
- 1732214030014-281.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.6 KB - Content
- 1732214076060-358.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.1 KB - Content
- 1732214111990-184.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.1 KB - Content
- 1732214146724-132.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.8 KB - Content
- 1732214183037-761.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.7 KB - Content
- 1732214207026-822.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.8 KB - Content
- 1732214237851-405.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.6 KB - Content
- 1732214272022-547.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- 1732214367207-318.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.2 KB - Content
- 1732214400721-274.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.9 KB - Content
- 1732214432750-543.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.1 KB - Content
- 1732214468462-541.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.3 KB - Content
- 1732214501360-654.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.1 KB - Content