Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -616,20 +616,179 @@ 616 616 To change the parameters of the watchdog protection, select the menu "Protections → WDT protection": 617 617 618 618 619 +In this section: 620 + 621 +* Enable – a flag to enable the protection; 622 +* Delay before clearing the error, second; 623 +* Lock the error until the device is reset. 624 + 625 +Conditions for removing the error: 626 + 627 +* the “Delay before clearing the error” time has passed from the board startup. 628 + 629 +(% class="box warningmessage" %) 630 +((( 631 +**If there is the "WDT reset" error, the “Critical error” is generated and all relays open.** 632 +))) 633 + 619 619 == 3.6.23 Insulation monitoring == 620 620 636 +BMS Main 2.x can detect a signal from an external insulation monitoring device (such as Bender IR155) to monitor the insulation quality. 637 + 638 +To change the insulation monitoring parameters, select the menu "Protections → Insulation monitoring": 639 + 640 + 641 +In this section: 642 + 643 +* Enable – a flag to enable the protection; 644 +* Delay before setting the error, second; 645 +* Delay before clearing the error, second; 646 +* Lock the error until the device is reset. 647 + 648 +Error is set if corresponding discrete input is set up and it received logical zero. 649 + 621 621 == 3.6.24 Critical error parameters == 622 622 652 +To change the critical error parameters, select the menu "Protections → Critical error parameters": 653 + 654 + 655 +In this section: 656 + 657 +* Enable – a flag to enable the protection; 658 +* Delay before setting the error, second; 659 +* Delay before clearing the error, second; 660 +* Lock the error until the device is reset. 661 + 662 +The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time: 663 + 664 +* “Battery cover error”; 665 +* “Water”; 666 +* “Logic offline”; 667 +* “Cell count error”; 668 +* “Logic count error”; 669 +* “ADC error”; 670 +* “No temp. sensors”; 671 +* “Temp. sensor is shorted”; 672 +* “Current sensor error”; 673 +* “Shunt offline”; 674 +* “Shunt error”; 675 +* “Settings error”; 676 +* “WDT reset”. 677 + 678 +The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 679 + 680 +(% class="box warningmessage" %) 681 +((( 682 +**If there is the “Critical error”, all relays open.** 683 +))) 684 + 623 623 == 3.6.25 General error parameters == 624 624 625 625 == 3.6.26 Low SOC signal == 626 626 689 +To change the parameters of the generation a signal about low battery level, select the menu "Protections → Low SOC signal": 690 + 691 + 692 +In this section: 693 + 694 +* Enable – a flag to enable signal generation; 695 +* Minimum SOC, %; 696 +* Tolerant SOC, %; 697 +* Delay before setting the signal, second; 698 +* Delay before clearing the signal, second; 699 +* Lock the signal until the device is reset. 700 + 701 +Signal generation conditions: 702 + 703 +* the battery SOC is less than the “Minimum SOC” value during the “Delay before setting the signal” time. 704 + 705 +Conditions for clearing the signal: 706 + 707 +* the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 708 + 709 +The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board. 710 + 627 627 == 3.6.27 High charging current signal == 628 628 713 +To change the parameters of the generation high-current signal, select the menu "Protections → High charging current signal": 714 + 715 + 716 +In this section: 717 + 718 +* Enable – a flag to enable signal generation; 719 +* Maximum charging current, А; 720 +* Tolerant charging current, А; 721 +* Delay before setting the signal, second; 722 +* Delay before clearing the signal, second; 723 +* Lock the signal until the device is reset. 724 + 725 +Signal generation conditions: 726 + 727 +* the measured current is greater than the “Maximum charging current” value during the “Delay before setting the signal” time. 728 + 729 +Conditions for clearing the signal: 730 + 731 +* the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 732 + 733 +The "High charging current" signal is //indicative //and can be linked to any discrete output of the board. 734 + 629 629 == 3.6.28 Heater control == 630 630 737 +To change the parameters of the heater control algorithm, select the menu "Protections → Heater control": 738 + 739 + 740 +In this section: 741 + 742 +* Enable – a flag to enable heater control; 743 +* Minimum cell temperature, °C; 744 +* Tolerant cell temperature, °C; 745 +* Delay before setting the signal, second; 746 +* Delay before clearing the signal, second; 747 +* Lock the signal until the device is reset; 748 +* Switch off the heater relay on errors (Undervoltage, Overcurrent, High temperature, Short circuit or Critical error). 749 + 750 +As a result of operating the heating algorithm, the “Heater” signal is generated. 751 + 752 +Conditions of signal generation: 753 + 754 +* The minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before setting the signal” time. 755 + 756 +Conditions for clearing the signal: 757 + 758 +* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 759 + 760 +(% class="box infomessage" %) 761 +((( 762 +If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 763 +))) 764 + 631 631 == 3.6.29 Heater (AUX) control == 632 632 767 +To change the parameters of the heater control algorithm, select the menu "Protections → Heater (AUX) control": 768 + 769 + 770 +In this section: 771 + 772 +* Enable – a flag to enable heater control; 773 +* Minimum cell temperature, °C; 774 +* Tolerant cell temperature, °C; 775 +* Delay before setting the signal, second; 776 +* Delay before clearing the signal, second; 777 +* Lock the signal until the device is reset; 778 +* Switch off the heater relay on errors (Undervoltage, Overcurrent, High temperature, Short circuit or Critical error). 779 + 780 +As a result of operating the heating algorithm, the “Heater (AUX)” signal is generated. 781 + 782 +Conditions of signal generation: 783 + 784 +* The minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before setting the signal” time. 785 + 786 +Conditions for clearing the signal: 787 + 788 +* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 789 + 790 +If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 791 + 633 633 == 3.6.30 Cooler control == 634 634 635 635 == 3.6.31 Fault simulation ==