Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -616,14 +616,101 @@ 616 616 To change the parameters of the watchdog protection, select the menu "Protections → WDT protection": 617 617 618 618 619 +In this section: 620 + 621 +* Enable – a flag to enable the protection; 622 +* Delay before clearing the error, second; 623 +* Lock the error until the device is reset. 624 + 625 +Conditions for removing the error: 626 + 627 +* the “Delay before clearing the error” time has passed from the board startup. 628 + 629 +(% class="box warningmessage" %) 630 +((( 631 +**If there is the "WDT reset" error, the “Critical error” is generated and all relays open.** 632 +))) 633 + 619 619 == 3.6.23 Insulation monitoring == 620 620 636 +BMS Main 2.x can detect a signal from an external insulation monitoring device (such as Bender IR155) to monitor the insulation quality. 637 + 638 +To change the insulation monitoring parameters, select the menu "Protections → Insulation monitoring": 639 + 640 + 641 +In this section: 642 + 643 +* Enable – a flag to enable the protection; 644 +* Delay before setting the error, second; 645 +* Delay before clearing the error, second; 646 +* Lock the error until the device is reset. 647 + 648 +Error is set if corresponding discrete input is set up and it received logical zero. 649 + 621 621 == 3.6.24 Critical error parameters == 622 622 652 +To change the critical error parameters, select the menu "Protections → Critical error parameters": 653 + 654 + 655 +In this section: 656 + 657 +* Enable – a flag to enable the protection; 658 +* Delay before setting the error, second; 659 +* Delay before clearing the error, second; 660 +* Lock the error until the device is reset. 661 + 662 +The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time: 663 + 664 +* “Battery cover error”; 665 +* “Water”; 666 +* “Logic offline”; 667 +* “Cell count error”; 668 +* “Logic count error”; 669 +* “ADC error”; 670 +* “No temp. sensors”; 671 +* “Temp. sensor is shorted”; 672 +* “Current sensor error”; 673 +* “Shunt offline”; 674 +* “Shunt error”; 675 +* “Settings error”; 676 +* “WDT reset”. 677 + 678 +The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 679 + 680 +(% class="box warningmessage" %) 681 +((( 682 +**If there is the “Critical error”, all relays open.** 683 +))) 684 + 623 623 == 3.6.25 General error parameters == 624 624 625 625 == 3.6.26 Low SOC signal == 626 626 689 +To change the parameters of the generation a signal about low battery level, select the menu "Protections → Low SOC signal": 690 + 691 + 692 +In this section: 693 + 694 +* Enable – a flag to enable signal generation; 695 +* Minimum SOC, %; 696 +* Tolerant SOC, %; 697 +* Delay before setting the signal, second; 698 +* Delay before clearing the signal, second; 699 +* Lock the signal until the device is reset. 700 + 701 +Signal generation conditions: 702 + 703 +* the battery SOC is less than the “Minimum SOC” value during the “Delay before setting the signal” time. 704 + 705 +Conditions for clearing the signal: 706 + 707 +* the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 708 + 709 +(% class="box infomessage" %) 710 +((( 711 +The "Low SOC signal" is indicative and can be linked to any discrete output of the board. 712 +))) 713 + 627 627 == 3.6.27 High charging current signal == 628 628 629 629 == 3.6.28 Heater control ==