Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 23 added, 0 removed)
- 1732213953083-955.png
- 1732213990755-759.png
- 1732214030014-281.png
- 1732214076060-358.png
- 1732214111990-184.png
- 1732214146724-132.png
- 1732214183037-761.png
- 1732214207026-822.png
- 1732214237851-405.png
- 1732214272022-547.png
- 1732214367207-318.png
- 1732214400721-274.png
- 1732214432750-543.png
- 1732214468462-541.png
- 1732214501360-654.png
- 1732214545352-111.png
- 1732214579147-515.png
- 1732214641606-453.png
- 1732214675358-202.png
- 1732214703914-144.png
- 1732214731490-961.png
- 1732214761141-983.png
- 1732214987517-111.png
Details
- Page properties
-
- Content
-
... ... @@ -70,7 +70,7 @@ 70 70 71 71 To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection": 72 72 73 -[[image:1732212357972-295.png]] 73 +[[Overvoltage protection settings>>image:1732212357972-295.png||data-xwiki-image-style-alignment="center" height="218" width="338"]] 74 74 75 75 In this section: 76 76 ... ... @@ -103,6 +103,7 @@ 103 103 104 104 To change the battery protection parameters from low temperature, select the menu "Protections → Low temperature protection": 105 105 106 +[[Low temperature protection settings>>image:1732213953083-955.png||data-xwiki-image-style-alignment="center" height="237" width="338"]] 106 106 107 107 In this section: 108 108 ... ... @@ -137,6 +137,7 @@ 137 137 138 138 To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection": 139 139 141 +[[High temperature protection settings>>image:1732213990755-759.png||data-xwiki-image-style-alignment="center" height="258" width="370"]] 140 140 141 141 In this section: 142 142 ... ... @@ -169,6 +169,8 @@ 169 169 170 170 To change the protection parameters from opening the battery cover, select the menu "Protections → Battery cover protection": 171 171 174 +[[Battery cover protection settings>>image:1732214030014-281.png||data-xwiki-image-style-alignment="center" height="155" width="334"]] 175 + 172 172 In this section: 173 173 174 174 * Enable – a flag to enable the protection; ... ... @@ -197,12 +197,13 @@ 197 197 198 198 To change the protection parameters of the battery from high humidity, select the menu "Protections → High humidity protection": 199 199 204 +[[High humidity protection settings>>image:1732214076060-358.png||data-xwiki-image-style-alignment="center" height="185" width="321"]] 200 200 201 201 In this section: 202 202 203 203 * Enable – a flag to enable the protection; 204 -* Maximum humidty, RH%; 205 -* Tolerant humidty, RH%; 209 +* Maximum humidity, RH%; 210 +* Tolerant humidity, RH%; 206 206 * Delay before setting the error, second; 207 207 * Delay before clearing the error, second; 208 208 * Lock the error until the device is reset. ... ... @@ -226,6 +226,7 @@ 226 226 227 227 To change the protection parameters of the battery from water, select the menu "Protections → Water protection": 228 228 234 +[[Water protection settings>>image:1732214111990-184.png||data-xwiki-image-style-alignment="center" height="199" width="340"]] 229 229 230 230 In this section: 231 231 ... ... @@ -257,6 +257,7 @@ 257 257 258 258 To change the test parameters of the current sensor connection circuits, select the menu "Protections → Current sensor error": 259 259 266 +[[Current sensor error settings>>image:1732214146724-132.png||data-xwiki-image-style-alignment="center" height="438" width="365"]] 260 260 261 261 In this section: 262 262 ... ... @@ -290,6 +290,7 @@ 290 290 291 291 To change the protection parameters from short circuit, select the menu "Protections → Short circuit protection": 292 292 300 +[[Short circuit protection settings>>image:1732214207026-822.png||data-xwiki-image-style-alignment="center" height="528" width="371"]] 293 293 294 294 In this section: 295 295 ... ... @@ -323,6 +323,7 @@ 323 323 324 324 To change the overheating protection parameters of power contactors, select the menu "Protections → Contactor high temperature protection": 325 325 334 +[[Contactor high temperature protection settings>>image:1732214237851-405.png||data-xwiki-image-style-alignment="center" height="234" width="336"]] 326 326 327 327 In this section: 328 328 ... ... @@ -356,6 +356,7 @@ 356 356 357 357 To change the parameters of the unallowable charging protection, select the menu "Protections → Unallowable charging protection": 358 358 368 +[[Unallowable charging protection settings>>image:1732214272022-547.png||data-xwiki-image-style-alignment="center" height="145" width="312"]] 359 359 360 360 In this section: 361 361 ... ... @@ -385,6 +385,7 @@ 385 385 386 386 To change the protection parameters against sticking, select the menu "Protections → Stuck contactor protection": 387 387 398 +[[Stuck contactor protection settings>>image:1732214367207-318.png||data-xwiki-image-style-alignment="center" height="152" width="331"]] 388 388 389 389 In this section: 390 390 ... ... @@ -405,6 +405,7 @@ 405 405 406 406 To change the contactor feedback check parameters, select the menu "Protections → Contactor feedback check": 407 407 419 +[[Contactor feedback check settings>>image:1732214400721-274.png||data-xwiki-image-style-alignment="center" height="150" width="323"]] 408 408 409 409 In this section: 410 410 ... ... @@ -423,6 +423,7 @@ 423 423 424 424 To change the protection parameters against high frequency switching of the charging contactor, select the menu "Protections → Charging contactor cycles protection": 425 425 438 +[[Charging contactor cycles protection settings>>image:1732214432750-543.png||data-xwiki-image-style-alignment="center" height="260" width="336"]] 426 426 427 427 In this section: 428 428 ... ... @@ -455,6 +455,7 @@ 455 455 456 456 To change the protection parameters against high frequency switching of the discharging contactor, select the menu "Protections → Discharging contactor cycles protection": 457 457 471 +[[Discharging contactor cycles protection settings>>image:1732214468462-541.png||data-xwiki-image-style-alignment="center" height="269" width="346"]] 458 458 459 459 In this section: 460 460 ... ... @@ -487,6 +487,7 @@ 487 487 488 488 To change the protection parameters of the temperature sensors circuits, select the menu "Protections → Temperature sensor error": 489 489 504 +[[Temperature sensor error settings>>image:1732214501360-654.png||data-xwiki-image-style-alignment="center" height="154" width="334"]] 490 490 491 491 In this section: 492 492 ... ... @@ -506,6 +506,7 @@ 506 506 507 507 To change the overheating protection parameters of BMS Logic boards, select the menu "Protections → Logic high temperature protection": 508 508 524 +[[Logic high temperature protection settings>>image:1732214545352-111.png||data-xwiki-image-style-alignment="center" height="156" width="309"]] 509 509 510 510 In this section: 511 511 ... ... @@ -533,6 +533,7 @@ 533 533 534 534 To change the protection parameters from loss of communication with BMS Logic boards, select the menu "Protections → Logic offline protection": 535 535 552 +[[Logic offline protection settings>>image:1732214579147-515.png||data-xwiki-image-style-alignment="center" height="107" width="204"]] 536 536 537 537 In this section: 538 538 ... ... @@ -558,6 +558,7 @@ 558 558 559 559 To change the protection parameters from the mismatch of the number of cells to the set value, select the menu "Protections → Cell count protection": 560 560 578 +[[Cell count protection settings>>image:1732214641606-453.png||data-xwiki-image-style-alignment="center" height="178" width="341"]] 561 561 562 562 In this section: 563 563 ... ... @@ -586,6 +586,7 @@ 586 586 587 587 To change the protection parameters from the mismatch of the number of BMS Logic boards to the set value, select the menu "Protections → Logic count protection": 588 588 607 +[[Logic count protection settings>>image:1732214675358-202.png||data-xwiki-image-style-alignment="center" height="163" width="230"]] 589 589 590 590 In this section: 591 591 ... ... @@ -615,21 +615,267 @@ 615 615 616 616 To change the parameters of the watchdog protection, select the menu "Protections → WDT protection": 617 617 637 +[[WDT protection settings>>image:1732214703914-144.png||data-xwiki-image-style-alignment="center" height="127" width="323"]] 618 618 639 +In this section: 640 + 641 +* Enable – a flag to enable the protection; 642 +* Delay before clearing the error, second; 643 +* Lock the error until the device is reset. 644 + 645 +Conditions for removing the error: 646 + 647 +* the “Delay before clearing the error” time has passed from the board startup. 648 + 649 +(% class="box warningmessage" %) 650 +((( 651 +**If there is the "WDT reset" error, the “Critical error” is generated and all relays open.** 652 +))) 653 + 619 619 == 3.6.23 Insulation monitoring == 620 620 656 +BMS Main 2.x can detect a signal from an external insulation monitoring device (such as Bender IR155) to monitor the insulation quality. 657 + 658 +To change the insulation monitoring parameters, select the menu "Protections → Insulation monitoring": 659 + 660 +[[Insulation monitoring settings>>image:1732214731490-961.png||data-xwiki-image-style-alignment="center" height="162" width="315"]] 661 + 662 +In this section: 663 + 664 +* Enable – a flag to enable the protection; 665 +* Delay before setting the error, second; 666 +* Delay before clearing the error, second; 667 +* Lock the error until the device is reset. 668 + 669 +Error is set if corresponding discrete input is set up and it received logical zero. 670 + 621 621 == 3.6.24 Critical error parameters == 622 622 673 +To change the critical error parameters, select the menu "Protections → Critical error parameters": 674 + 675 +[[Critical error parameters settings>>image:1732214761141-983.png||data-xwiki-image-style-alignment="center" height="158" width="348"]] 676 + 677 +In this section: 678 + 679 +* Enable – a flag to enable the protection; 680 +* Delay before setting the error, second; 681 +* Delay before clearing the error, second; 682 +* Lock the error until the device is reset. 683 + 684 +The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time: 685 + 686 +* “Battery cover error”; 687 +* “Water”; 688 +* “Logic offline”; 689 +* “Cell count error”; 690 +* “Logic count error”; 691 +* “ADC error”; 692 +* “No temp. sensors”; 693 +* “Temp. sensor is shorted”; 694 +* “Current sensor error”; 695 +* “Shunt offline”; 696 +* “Shunt error”; 697 +* “Settings error”; 698 +* “WDT reset”. 699 + 700 +The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 701 + 702 +(% class="box warningmessage" %) 703 +((( 704 +**If there is the “Critical error”, all relays open.** 705 +))) 706 + 623 623 == 3.6.25 General error parameters == 624 624 709 +To change the general error parameters, select the menu "Protections → General error parameters": 710 + 711 +[[General error parameters settings>>image:1732214987517-111.png||data-xwiki-image-style-alignment="center" height="535" width="349"]] 712 + 713 +In this section: 714 + 715 +* Enable – a flag to enable the protection; 716 +* Delay before setting the error, second; 717 +* Delay before clearing the error, second; 718 +* Lock the error until the device is reset. 719 + 625 625 == 3.6.26 Low SOC signal == 626 626 722 +To change the parameters of the generation a signal about low battery level, select the menu "Protections → Low SOC signal": 723 + 724 + 725 +In this section: 726 + 727 +* Enable – a flag to enable signal generation; 728 +* Minimum SOC, %; 729 +* Tolerant SOC, %; 730 +* Delay before setting the signal, second; 731 +* Delay before clearing the signal, second; 732 +* Lock the signal until the device is reset. 733 + 734 +Signal generation conditions: 735 + 736 +* the battery SOC is less than the “Minimum SOC” value during the “Delay before setting the signal” time. 737 + 738 +Conditions for clearing the signal: 739 + 740 +* the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 741 + 742 +The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board. 743 + 627 627 == 3.6.27 High charging current signal == 628 628 746 +To change the parameters of the generation high-current signal, select the menu "Protections → High charging current signal": 747 + 748 + 749 +In this section: 750 + 751 +* Enable – a flag to enable signal generation; 752 +* Maximum charging current, А; 753 +* Tolerant charging current, А; 754 +* Delay before setting the signal, second; 755 +* Delay before clearing the signal, second; 756 +* Lock the signal until the device is reset. 757 + 758 +Signal generation conditions: 759 + 760 +* the measured current is greater than the “Maximum charging current” value during the “Delay before setting the signal” time. 761 + 762 +Conditions for clearing the signal: 763 + 764 +* the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 765 + 766 +The "High charging current" signal is //indicative //and can be linked to any discrete output of the board. 767 + 629 629 == 3.6.28 Heater control == 630 630 770 +To change the parameters of the heater control algorithm, select the menu "Protections → Heater control": 771 + 772 + 773 +In this section: 774 + 775 +* Enable – a flag to enable heater control; 776 +* Minimum cell temperature, °C; 777 +* Tolerant cell temperature, °C; 778 +* Delay before setting the signal, second; 779 +* Delay before clearing the signal, second; 780 +* Lock the signal until the device is reset; 781 +* Switch off the heater relay on errors (Undervoltage, Overcurrent, High temperature, Short circuit or Critical error). 782 + 783 +As a result of operating the heating algorithm, the “Heater” signal is generated. 784 + 785 +Conditions of signal generation: 786 + 787 +* The minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before setting the signal” time. 788 + 789 +Conditions for clearing the signal: 790 + 791 +* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 792 + 793 +(% class="box infomessage" %) 794 +((( 795 +If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 796 +))) 797 + 631 631 == 3.6.29 Heater (AUX) control == 632 632 800 +To change the parameters of the auxiliary heater control algorithm, select the menu "Protections → Heater (AUX) control": 801 + 802 + 803 +In this section: 804 + 805 +* Enable – a flag to enable heater control; 806 +* Minimum cell temperature, °C; 807 +* Tolerant cell temperature, °C; 808 +* Delay before setting the signal, second; 809 +* Delay before clearing the signal, second; 810 +* Lock the signal until the device is reset; 811 +* Switch off the heater relay on errors (Undervoltage, Overcurrent, High temperature, Short circuit or Critical error). 812 + 813 +As a result of operating the heating algorithm, the “Heater (AUX)” signal is generated. 814 + 815 +Conditions of signal generation: 816 + 817 +* The minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before setting the signal” time. 818 + 819 +Conditions for clearing the signal: 820 + 821 +* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 822 + 823 +(% class="box infomessage" %) 824 +((( 825 +If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output. 826 +))) 827 + 633 633 == 3.6.30 Cooler control == 634 634 830 +To change the parameters of the cooler control algorithm, select the menu "Protections → Cooler control": 831 + 832 + 833 +In this section: 834 + 835 +* Enable – a flag to enable cooler control; 836 +* Maximum cell temperature, °C; 837 +* Tolerant cell temperature, °C; 838 +* Delay before setting the signal, second; 839 +* Delay before clearing the signal, second; 840 +* Lock the signal until the device is reset; 841 +* Switch off the cooler relay on errors (Undervoltage, Overcurrent, Low temperature, Short circuit or Critical error). 842 + 843 +As a result of operating the cooling algorithm, the "Cooler" signal is generated. 844 + 845 +Conditions of signal generation: 846 + 847 +* the maximum temperature among all cells of the battery is greater than the “Maximum cell temperature” value during the “Delay before setting the signal” time. 848 + 849 +Conditions for clearing the signal: 850 + 851 +* the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 852 + 853 +(% class="box infomessage" %) 854 +((( 855 +If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output. 856 +))) 857 + 635 635 == 3.6.31 Fault simulation == 859 + 860 +The board provides the ability to manually generate error flags bypassing the protection algorithms. This functionality is intended for commissioning. 861 + 862 +To simulate battery and BMS errors, select the menu "Protections → Fault simulation": 863 + 864 + 865 +In this section: 866 + 867 +* Overcurrent; 868 +* Undervoltage; 869 +* Overvoltage; 870 +* Low CH temperature; 871 +* Low DCH temperature; 872 +* High CH temperature; 873 +* High DCH temperature; 874 +* Battery cover error; 875 +* High humidity; 876 +* Water; 877 +* Current sensor error; 878 +* Short circuit; 879 +* Contactor high temperature; 880 +* Unallowable charging; 881 +* Stuck contactor; 882 +* CH contactor feedback error; 883 +* DCH contactor feedback error; 884 +* PCH contactor feedback error; 885 +* CH/DCH contactor feedback error; 886 +* Main contactor feedback error; 887 +* CH contactor cycles error; 888 +* DCH contactor cycles error; 889 +* Logic high temperature; 890 +* Logic offline; 891 +* Cell count error; 892 +* Logic count error; 893 +* Insulation error; 894 +* Critical error; 895 +* Low SOC; 896 +* High charging current; 897 +* Heater; 898 +* Cooler. 899 + 900 +To simulate errors, set the necessary flags and click on the "Save" button.
- 1732213953083-955.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.0 KB - Content
- 1732213990755-759.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.7 KB - Content
- 1732214030014-281.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.6 KB - Content
- 1732214076060-358.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.1 KB - Content
- 1732214111990-184.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.1 KB - Content
- 1732214146724-132.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.8 KB - Content
- 1732214183037-761.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.7 KB - Content
- 1732214207026-822.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.8 KB - Content
- 1732214237851-405.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.6 KB - Content
- 1732214272022-547.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- 1732214367207-318.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.2 KB - Content
- 1732214400721-274.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.9 KB - Content
- 1732214432750-543.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.1 KB - Content
- 1732214468462-541.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.3 KB - Content
- 1732214501360-654.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.1 KB - Content
- 1732214545352-111.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.2 KB - Content
- 1732214579147-515.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.5 KB - Content
- 1732214641606-453.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.8 KB - Content
- 1732214675358-202.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.1 KB - Content
- 1732214703914-144.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.6 KB - Content
- 1732214731490-961.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- 1732214761141-983.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.1 KB - Content
- 1732214987517-111.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.3 KB - Content