Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -534,13 +534,100 @@ 534 534 To change the protection parameters from loss of communication with BMS Logic boards, select the menu "Protections → Logic offline protection": 535 535 536 536 537 +In this section: 537 537 539 +* Enable – a flag to enable the protection; 540 +* Lock the error until the device is reset. 541 + 542 +As a result of the protection from loss of communication with BMS Logic boards, the "Logic offline" error is generated. 543 + 544 +Error generation conditions: 545 + 546 +* at least one of the connected BMS Logic boards does not respond to the commands of the BMS Main 2.x board for 10 seconds. 547 + 548 +Conditions for removing the error: 549 + 550 +* all connected BMS Logic boards respond to the commands of the BMS Main 2.x board. 551 + 552 +(% class="box warningmessage" %) 553 +((( 554 +**If there is the "Logic offline" error, the “Critical error” is generated and all relays open.** 555 +))) 556 + 538 538 == 3.6.20 Cell count protection == 539 539 559 +To change the protection parameters from the mismatch of the number of cells to the set value, select the menu "Protections → Cell count protection": 560 + 561 + 562 +In this section: 563 + 564 +* Enable – a flag to enable the protection; 565 +* Cell count – a number of cells connected to the BMS; 566 +* Delay before setting the error, second; 567 +* Delay before clearing the error, second; 568 +* Lock the error until the device is reset. 569 + 570 +As a result of the operation of the protection from the mismatch of the number of cells, the "Cell count error" is generated. 571 + 572 +Error generation conditions: 573 + 574 +* the number of cells connected to the BMS is **not equal** to the “Cell count” value during the “Delay before setting the error” time. 575 + 576 +Conditions for removing the error: 577 + 578 +* the number of cells connected to the BMS is **equal** to the “Cell count” value during the “Delay before clearing the error” time. 579 + 580 +(% class="box warningmessage" %) 581 +((( 582 +**If there is the "Cell count error", the “Critical error” is generated and all relays open.** 583 +))) 584 + 540 540 == 3.6.21 Logic count protection == 541 541 587 +To change the protection parameters from the mismatch of the number of BMS Logic boards to the set value, select the menu "Protections → Logic count protection": 588 + 589 + 590 +In this section: 591 + 592 +* Enable – a flag to enable the protection; 593 +* Logic count – a number of BMS Logic boards connected to the BMS Main 2.x; 594 +* Fast scan – a flag to scan BMS Logic boards fast (boards with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time); 595 +* Lock the error until the device is reset. 596 + 597 +As a result of the operation of the protection from the mismatch of the number of BMS Logic boards, the "Logic count error" is generated. 598 + 599 +Error generation conditions: 600 + 601 +* the number of BMS Logic boards connected to the BMS Main 2.x is **not equal** to the “Logic count” value. 602 + 603 +Conditions for removing the error: 604 + 605 +* the number of BMS Logic boards connected to the BMS Main is **equal** to the “Logic count” value. 606 + 607 +(% class="box warningmessage" %) 608 +((( 609 +**If there is the "Logic count error", the “Critical error” is generated and all relays open.** 610 +))) 611 + 542 542 == 3.6.22 WDT protection == 543 543 614 +If the BMS firmware hangs, the watchdog timer resets the board. The BMS can detect that the board was reset and generates the “WDT reset” error. 615 + 616 +To change the parameters of the watchdog protection, select the menu "Protections → WDT protection": 617 + 618 + 619 +In this section: 620 + 621 +* Enable – a flag to enable the protection; 622 +* Delay before clearing the error, second; 623 +* Lock the error until the device is reset. 624 + 625 +Conditions for removing the error: 626 + 627 +* the “Delay before clearing the error” time has passed from the board startup. 628 + 629 +**If there is the "WDT reset" error, the “Critical error” is generated and all relays open.** 630 + 544 544 == 3.6.23 Insulation monitoring == 545 545 546 546 == 3.6.24 Critical error parameters ==