... ... @@ -197,7 +197,6 @@
197 197  
198 198  To change the protection parameters of the battery from high humidity, select the menu "Protections → High humidity protection":
199 199  
200 -
201 201  In this section:
202 202  
203 203  * Enable – a flag to enable the protection;
... ... @@ -217,70 +217,13 @@
217 217  
218 218  * the measured humidity is less than the “Tolerant humidity” during the “Delay before clearing the error” time.
219 219  
220 -(% class="box infomessage" %)
221 -(((
222 222  If there is the "High humidity" error, no action is taken. The error is indicative.
223 -)))
224 224  
221 +
225 225  == 3.6.8  Water protection ==
226 226  
227 -To change the protection parameters of the battery from water, select the menu "Protections → Water protection":
228 -
229 -
230 -In this section:
231 -
232 -* Enable – a flag to enable the protection;
233 -* Maximum (water) humidty, RH%;
234 -* Tolerant humidity, RH%;
235 -* Delay before setting the error, second;
236 -* Delay before clearing the error, second;
237 -* Lock the error until the device is reset.
238 -
239 -As a result of the operation of the battery protection from water, the "Water" error is generated.
240 -
241 -Error generation conditions:
242 -
243 -* the measured humidity is greater than the “Maximum (water) humidity” value during the “Delay before setting the error” time.
244 -
245 -Conditions for removing the error:
246 -
247 -* the measured humidity is less than the “Tolerant humidity” value during the “Delay before clearing the error” time.
248 -
249 -(% class="box warningmessage" %)
250 -(((
251 -**If there is the “Water” error, the “Critical error” is generated and all relays open.**
252 -)))
253 -
254 254  == 3.6.9 Current sensor error ==
255 255  
256 -The board is implemented to check the current sensor connection circuits. The circuits are checked for breakage and short-circuit to the +5 V supply line.
257 -
258 -To change the test parameters of the current sensor connection circuits, select the menu "Protections → Current sensor error":
259 -
260 -
261 -In this section:
262 -
263 -* Enable – a flag to enable the protection;
264 -* Maximum voltage, V;
265 -* Minimum voltage, V;
266 -* Hysteresis voltage – a hysteresis value to clear the error, V;
267 -* Delay before setting the error, second;
268 -* Delay before clearing the error, second;
269 -* Lock the error until the device is reset.
270 -
271 -If there is an open or short circuit connection of a current sensor, the "Current sensor error" is generated.
272 -
273 -Error generation conditions:
274 -
275 -* the voltage in the signal line or zero level line of the current sensor is greater than the “Maximum voltage” value during the “Delay before setting the error” time;
276 -* the voltage in the signal line or zero level line of the current sensor is less than the “Minimum voltage” value during the “Delay before setting the error” time.
277 -
278 -Conditions for removing the error:
279 -
280 -* the voltage in the signal line or zero level line of the current sensor is in range from (Minimum voltage + Hysteresis voltage) to (Maximum voltage - Hysteresis voltage) during the “Delay before clearing the error” time.
281 -
282 -**If there is the “Current sensor error”, the “Critical error” is generated and all relays open.**
283 -
284 284  == 3.6.10 Short circuit protection ==
285 285  
286 286  == 3.6.11 Contactor high temperature protection ==