Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,8 +6,9 @@ 6 6 7 7 [[Overcurrent protection settings>>image:1732211959984-118.png||data-xwiki-image-style-alignment="center" height="266" width="386"]] 8 8 9 - In this section: 10 10 10 +In this section: 11 + 11 11 * Enable – a flag to enable the protection; 12 12 * Maximum charging current, А; 13 13 * Tolerant charging current, А; ... ... @@ -31,7 +31,7 @@ 31 31 32 32 (% class="box infomessage" %) 33 33 ((( 34 -If there is the "Overcurrent" error, the charging and discharging relay open. 35 +If there is the "Overcurrent" error, the charging relay and discharging relay open. 35 35 ))) 36 36 37 37 == 3.6.2 Undervoltage protection == ... ... @@ -127,8 +127,7 @@ 127 127 128 128 (% class="box infomessage" %) 129 129 ((( 130 -If there is the "Low CH temperature" error, the charging relay opens. 131 -If there is the "Low DCH temperature" error, the discharging relay opens. 131 +If there is the "Low CH temperature" error, the charging relay opens. If there is the "Low DCH temperature" error, the discharging relay opens. 132 132 ))) 133 133 134 134 == 3.6.5 High temperature protection == ... ... @@ -137,7 +137,6 @@ 137 137 138 138 To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection": 139 139 140 - 141 141 In this section: 142 142 143 143 * Enable – a flag to enable the protection; ... ... @@ -167,120 +167,12 @@ 167 167 168 168 == 3.6.6 Battery cover protection == 169 169 170 - Tochangethe protection parameters from openingthebattery cover, select the menu"Protections → Batterycoverprotection":169 +== 3.6.7 High humidity protection == 171 171 172 -In this section: 173 - 174 -* Enable – a flag to enable the protection; 175 -* Delay before setting the error, second; 176 -* Delay before clearing the error, second; 177 -* Lock the error until the device is reset. 178 - 179 -As a result of the operation of the protection against opening the battery cover, the “Battery cover error” is generated. 180 - 181 -Error generation conditions: 182 - 183 -* there is a signal from the battery cover during the “Delay before setting the error” time. 184 - 185 -Conditions for removing the error: 186 - 187 -* no signal from the battery cover during the “Delay before clearing the error” time. 188 - 189 -(% class="box warningmessage" %) 190 -((( 191 -**If there is the "Battery cover error", the “Critical error” is generated and all relays open.** 192 -))) 193 - 194 -== 3.6.7 High humidity protection == 195 - 196 -The board can protect the battery from high humidity and water. 197 - 198 -To change the protection parameters of the battery from high humidity, select the menu "Protections → High humidity protection": 199 - 200 - 201 -In this section: 202 - 203 -* Enable – a flag to enable the protection; 204 -* Maximum humidty, RH%; 205 -* Tolerant humidty, RH%; 206 -* Delay before setting the error, second; 207 -* Delay before clearing the error, second; 208 -* Lock the error until the device is reset. 209 - 210 -As a result of the operation of the battery protection from high humidity, the "High humidity" error is generated. 211 - 212 -Error generation conditions: 213 - 214 -* the measured humidity is greater than “Maximum humidity” during the “Delay before setting the error” time. 215 - 216 -Conditions for removing the error: 217 - 218 -* the measured humidity is less than the “Tolerant humidity” during the “Delay before clearing the error” time. 219 - 220 -(% class="box infomessage" %) 221 -((( 222 -If there is the "High humidity" error, no action is taken. The error is indicative. 223 -))) 224 - 225 225 == 3.6.8 Water protection == 226 226 227 -To change the protection parameters of the battery from water, select the menu "Protections → Water protection": 228 - 229 - 230 -In this section: 231 - 232 -* Enable – a flag to enable the protection; 233 -* Maximum (water) humidty, RH%; 234 -* Tolerant humidity, RH%; 235 -* Delay before setting the error, second; 236 -* Delay before clearing the error, second; 237 -* Lock the error until the device is reset. 238 - 239 -As a result of the operation of the battery protection from water, the "Water" error is generated. 240 - 241 -Error generation conditions: 242 - 243 -* the measured humidity is greater than the “Maximum (water) humidity” value during the “Delay before setting the error” time. 244 - 245 -Conditions for removing the error: 246 - 247 -* the measured humidity is less than the “Tolerant humidity” value during the “Delay before clearing the error” time. 248 - 249 -(% class="box warningmessage" %) 250 -((( 251 -**If there is the “Water” error, the “Critical error” is generated and all relays open.** 252 -))) 253 - 254 254 == 3.6.9 Current sensor error == 255 255 256 -The board is implemented to check the current sensor connection circuits. The circuits are checked for breakage and short-circuit to the +5 V supply line. 257 - 258 -To change the test parameters of the current sensor connection circuits, select the menu "Protections → Current sensor error": 259 - 260 - 261 -In this section: 262 - 263 -* Enable – a flag to enable the protection; 264 -* Maximum voltage, V; 265 -* Minimum voltage, V; 266 -* Hysteresis voltage – a hysteresis value to clear the error, V; 267 -* Delay before setting the error, second; 268 -* Delay before clearing the error, second; 269 -* Lock the error until the device is reset. 270 - 271 -If there is an open or short circuit connection of a current sensor, the "Current sensor error" is generated. 272 - 273 -Error generation conditions: 274 - 275 -* the voltage in the signal line or zero level line of the current sensor is greater than the “Maximum voltage” value during the “Delay before setting the error” time; 276 -* the voltage in the signal line or zero level line of the current sensor is less than the “Minimum voltage” value during the “Delay before setting the error” time. 277 - 278 -Conditions for removing the error: 279 - 280 -* the voltage in the signal line or zero level line of the current sensor is in range from (Minimum voltage + Hysteresis voltage) to (Maximum voltage - Hysteresis voltage) during the “Delay before clearing the error” time. 281 - 282 -**If there is the “Current sensor error”, the “Critical error” is generated and all relays open.** 283 - 284 284 == 3.6.10 Short circuit protection == 285 285 286 286 == 3.6.11 Contactor high temperature protection ==