... ... @@ -6,8 +6,9 @@
6 6  
7 7  [[Overcurrent protection settings>>image:1732211959984-118.png||data-xwiki-image-style-alignment="center" height="266" width="386"]]
8 8  
9 - In this section:
10 10  
10 +In this section:
11 +
11 11  * Enable – a flag to enable the protection;
12 12  * Maximum charging current, А;
13 13  * Tolerant charging current, А;
... ... @@ -31,7 +31,7 @@
31 31  
32 32  (% class="box infomessage" %)
33 33  (((
34 -If there is the "Overcurrent" error, the charging and discharging relay open.
35 +If there is the "Overcurrent" error, the charging relay and discharging relay open.
35 35  )))
36 36  
37 37  == 3.6.2 Undervoltage protection ==
... ... @@ -191,34 +191,8 @@
191 191  **If there is the "Battery cover error", the “Critical error” is generated and all relays open.**
192 192  )))
193 193  
194 -== 3.6.7 High humidity protection ==
195 +== 3.6.7 High humidity protection ==
195 195  
196 -The board can protect the battery from high humidity and water.
197 -
198 -To change the protection parameters of the battery from high humidity, select the menu "Protections → High humidity protection":
199 -
200 -In this section:
201 -
202 -* Enable – a flag to enable the protection;
203 -* Maximum humidty, RH%;
204 -* Tolerant humidty, RH%;
205 -* Delay before setting the error, second;
206 -* Delay before clearing the error, second;
207 -* Lock the error until the device is reset.
208 -
209 -As a result of the operation of the battery protection from high humidity, the "High humidity" error is generated.
210 -
211 -Error generation conditions:
212 -
213 -* the measured humidity is greater than “Maximum humidity” during the “Delay before setting the error” time.
214 -
215 -Conditions for removing the error:
216 -
217 -* the measured humidity is less than the “Tolerant humidity” during the “Delay before clearing the error” time.
218 -
219 -If there is the "High humidity" error, no action is taken. The error is indicative.