Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,8 +6,9 @@ 6 6 7 7 [[Overcurrent protection settings>>image:1732211959984-118.png||data-xwiki-image-style-alignment="center" height="266" width="386"]] 8 8 9 - In this section: 10 10 10 +In this section: 11 + 11 11 * Enable – a flag to enable the protection; 12 12 * Maximum charging current, А; 13 13 * Tolerant charging current, А; ... ... @@ -31,7 +31,7 @@ 31 31 32 32 (% class="box infomessage" %) 33 33 ((( 34 -If there is the "Overcurrent" error, the charging and discharging relay open. 35 +If there is the "Overcurrent" error, the charging relay and discharging relay open. 35 35 ))) 36 36 37 37 == 3.6.2 Undervoltage protection == ... ... @@ -127,8 +127,7 @@ 127 127 128 128 (% class="box infomessage" %) 129 129 ((( 130 -If there is the "Low CH temperature" error, the charging relay opens. 131 -If there is the "Low DCH temperature" error, the discharging relay opens. 131 +If there is the "Low CH temperature" error, the charging relay opens. If there is the "Low DCH temperature" error, the discharging relay opens. 132 132 ))) 133 133 134 134 == 3.6.5 High temperature protection == ... ... @@ -137,7 +137,6 @@ 137 137 138 138 To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection": 139 139 140 - 141 141 In this section: 142 142 143 143 * Enable – a flag to enable the protection; ... ... @@ -167,58 +167,8 @@ 167 167 168 168 == 3.6.6 Battery cover protection == 169 169 170 - Tochangethe protection parameters from openingthebattery cover, select the menu"Protections → Batterycoverprotection":169 +== 3.6.7 High humidity protection == 171 171 172 -In this section: 173 - 174 -* Enable – a flag to enable the protection; 175 -* Delay before setting the error, second; 176 -* Delay before clearing the error, second; 177 -* Lock the error until the device is reset. 178 - 179 -As a result of the operation of the protection against opening the battery cover, the “Battery cover error” is generated. 180 - 181 -Error generation conditions: 182 - 183 -* there is a signal from the battery cover during the “Delay before setting the error” time. 184 - 185 -Conditions for removing the error: 186 - 187 -* no signal from the battery cover during the “Delay before clearing the error” time. 188 - 189 -(% class="box warningmessage" %) 190 -((( 191 -**If there is the "Battery cover error", the “Critical error” is generated and all relays open.** 192 -))) 193 - 194 -== 3.6.7 High humidity protection == 195 - 196 -The board can protect the battery from high humidity and water. 197 - 198 -To change the protection parameters of the battery from high humidity, select the menu "Protections → High humidity protection": 199 - 200 -In this section: 201 - 202 -* Enable – a flag to enable the protection; 203 -* Maximum humidty, RH%; 204 -* Tolerant humidty, RH%; 205 -* Delay before setting the error, second; 206 -* Delay before clearing the error, second; 207 -* Lock the error until the device is reset. 208 - 209 -As a result of the operation of the battery protection from high humidity, the "High humidity" error is generated. 210 - 211 -Error generation conditions: 212 - 213 -* the measured humidity is greater than “Maximum humidity” during the “Delay before setting the error” time. 214 - 215 -Conditions for removing the error: 216 - 217 -* the measured humidity is less than the “Tolerant humidity” during the “Delay before clearing the error” time. 218 - 219 -If there is the "High humidity" error, no action is taken. The error is indicative. 220 - 221 - 222 222 == 3.6.8 Water protection == 223 223 224 224 == 3.6.9 Current sensor error ==