Changes for page 3.6 Battery protection

Last modified by Admin on 2025/04/09 12:25

From version 4.12
edited by Admin
on 2024/11/21 18:16
Change comment: There is no comment for this version
To version 4.5
edited by Admin
on 2024/11/21 18:08
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -98,146 +98,35 @@
98 98  If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set).
99 99  )))
100 100  
101 -== 3.6.4 Low temperature protection ==
101 +3.6.4 Low temperature protection
102 102  
103 -The board implements battery protection from too low temperature.
103 +3.6.5 High temperature protection
104 104  
105 -To change the battery protection parameters from low temperature, select the menu "Protections → Low temperature protection":
105 +3.6.6 Battery cover protection
106 106  
107 +3.6.7 High humidity protection
107 107  
108 -In this section:
109 -
110 -* Enable – a flag to enable the protection;
111 -* Minimum charging temperature, °C;
112 -* Tolerant charging temperature, °C;
113 -* Minimum discharging temperature, °C;
114 -* Tolerant discharging temperature, °C;
115 -* Delay before setting the error, second;
116 -* Delay before clearing the error, second;
117 -* Lock the error until the device is reset.
118 -
119 -As a result of the operation of the battery protection from low temperature, the "Low CH temperature" or “Low DCH temperature” error is generated.
120 -
121 -Error generation conditions:
122 -
123 -* the minimum temperature among all cells of the battery is less than the “Minimum charging (discharging) temperature” value for the “Delay before setting the error” time.
124 -
125 -Conditions for removing the error:
126 -
127 -* the minimum temperature among all cells of the battery is greater than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time.
128 -
129 -(% class="box infomessage" %)
130 -(((
131 -If there is the "Low CH temperature" error, the charging relay opens.
132 -If there is the "Low DCH temperature" error, the discharging relay opens.
133 -)))
134 -
135 -== 3.6.5 High temperature protection ==
136 -
137 -The board implements battery protection from too high temperature.
138 -
139 -To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection":
140 -
141 -
142 -In this section:
143 -
144 -* Enable – a flag to enable the protection;
145 -* Maximum charging temperature, °C;
146 -* Tolerant charging temperature, °C;
147 -* Maximum discharging temperature, °C;
148 -* Tolerant discharging temperature, °C;
149 -* Delay before setting the error, second;
150 -* Delay before clearing the error, second;
151 -* Lock the error until the device is reset.
152 -
153 -As a result of the operation of the battery protection from high temperature, the "High CH temperature" or “High DCH temperature” error is generated.
154 -
155 -Error generation conditions:
156 -
157 -* the maximum temperature among all cells of the battery is greater than the “Maximum charging (discharging) temperature” value for the “Delay before setting the error” time.
158 -
159 -Conditions for removing the error:
160 -
161 -* the maximum temperature among all cells of the battery is less than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time.
162 -
163 -(% class="box infomessage" %)
164 -(((
165 -If there is the "High CH temperature" error, the charging relay opens.
166 -If there is the "High DCH temperature" error, the discharging relay opens.
167 -)))
168 -
169 -== 3.6.6 Battery cover protection ==
170 -
171 -To change the protection parameters from opening the battery cover, select the menu "Protections → Battery cover protection":
172 -
173 -In this section:
174 -
175 -* Enable – a flag to enable the protection;
176 -* Delay before setting the error, second;
177 -* Delay before clearing the error, second;
178 -* Lock the error until the device is reset.
179 -
180 -As a result of the operation of the protection against opening the battery cover, the “Battery cover error” is generated.
181 -
182 -Error generation conditions:
183 -
184 -* there is a signal from the battery cover during the “Delay before setting the error” time.
185 -
186 -Conditions for removing the error:
187 -
188 -* no signal from the battery cover during the “Delay before clearing the error” time.
189 -
190 -(% class="box warningmessage" %)
191 -(((
192 -**If there is the "Battery cover error", the “Critical error” is generated and all relays open.**
193 -)))
194 -
195 -== 3.6.7 High humidity protection ==
196 -
197 -== 3.6.8  Water protection ==
198 -
199 -== 3.6.9 Current sensor error ==
200 -
201 -== 3.6.10 Short circuit protection ==
202 -
203 -== 3.6.11 Contactor high temperature protection ==
204 -
205 -== 3.6.12 Unallowable charging protection ==
206 -
207 -== 3.6.13 Stuck contactor protection ==
208 -
209 -== 3.6.14 Contactor feedback check ==
210 -
211 -== 3.6.15 Charging contactor cycles protection ==
212 -
213 -== 3.6.16 Discharging contactor cycles protection ==
214 -
215 -== 3.6.17 Temperature sensor error ==
216 -
217 -== 3.6.18 Logic high temperature protection ==
218 -
219 -== 3.6.19 Logic offline protection ==
220 -
221 -== 3.6.20 Cell count protection ==
222 -
223 -== 3.6.21 Logic count protection ==
224 -
225 -== 3.6.22 WDT protection ==
226 -
227 -== 3.6.23 Insulation monitoring ==
228 -
229 -== 3.6.24 Critical error parameters ==
230 -
231 -== 3.6.25 General error parameters ==
232 -
233 -== 3.6.26 Low SOC signal ==
234 -
235 -== 3.6.27 High charging current signal ==
236 -
237 -== 3.6.28 Heater control ==
238 -
239 -== 3.6.29 Heater (AUX) control ==
240 -
241 -== 3.6.30 Cooler control ==
242 -
243 -== 3.6.31 Fault simulation ==
109 +3.6.8  Water protection
110 +Current sensor error
111 +Short circuit protection
112 +Contactor high temperature protection
113 +Unallowable charging protection
114 +Stuck contactor protection
115 +Contactor feedback check
116 +Charging contactor cycles protection
117 +Discharging contactor cycles protection
118 +Temperature sensor error
119 +Logic high temperature protection
120 +Logic offline protection
121 +Cell count protection
122 +Logic count protection
123 +WDT protection
124 +Insulation monitoring
125 +Critical error parameters
126 +General error parameters
127 +Low SOC signal
128 +High charging current signal
129 +Heater control
130 +Heater (AUX) control
131 +Cooler control
132 +Fault simulation