Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,9 +6,8 @@ 6 6 7 7 [[Overcurrent protection settings>>image:1732211959984-118.png||data-xwiki-image-style-alignment="center" height="266" width="386"]] 8 8 9 + In this section: 9 9 10 -In this section: 11 - 12 12 * Enable – a flag to enable the protection; 13 13 * Maximum charging current, А; 14 14 * Tolerant charging current, А; ... ... @@ -32,7 +32,7 @@ 32 32 33 33 (% class="box infomessage" %) 34 34 ((( 35 -If there is the "Overcurrent" error, the charging relay and discharging relay open.34 +If there is the "Overcurrent" error, the charging and discharging relay open. 36 36 ))) 37 37 38 38 == 3.6.2 Undervoltage protection == ... ... @@ -192,12 +192,96 @@ 192 192 **If there is the "Battery cover error", the “Critical error” is generated and all relays open.** 193 193 ))) 194 194 195 -== 3.6.7 High humidity protection 194 +== 3.6.7 High humidity protection == 196 196 196 +The board can protect the battery from high humidity and water. 197 + 198 +To change the protection parameters of the battery from high humidity, select the menu "Protections → High humidity protection": 199 + 200 + 201 +In this section: 202 + 203 +* Enable – a flag to enable the protection; 204 +* Maximum humidty, RH%; 205 +* Tolerant humidty, RH%; 206 +* Delay before setting the error, second; 207 +* Delay before clearing the error, second; 208 +* Lock the error until the device is reset. 209 + 210 +As a result of the operation of the battery protection from high humidity, the "High humidity" error is generated. 211 + 212 +Error generation conditions: 213 + 214 +* the measured humidity is greater than “Maximum humidity” during the “Delay before setting the error” time. 215 + 216 +Conditions for removing the error: 217 + 218 +* the measured humidity is less than the “Tolerant humidity” during the “Delay before clearing the error” time. 219 + 220 +(% class="box infomessage" %) 221 +((( 222 +If there is the "High humidity" error, no action is taken. The error is indicative. 223 +))) 224 + 197 197 == 3.6.8 Water protection == 198 198 227 +To change the protection parameters of the battery from water, select the menu "Protections → Water protection": 228 + 229 + 230 +In this section: 231 + 232 +* Enable – a flag to enable the protection; 233 +* Maximum (water) humidty, RH%; 234 +* Tolerant humidity, RH%; 235 +* Delay before setting the error, second; 236 +* Delay before clearing the error, second; 237 +* Lock the error until the device is reset. 238 + 239 +As a result of the operation of the battery protection from water, the "Water" error is generated. 240 + 241 +Error generation conditions: 242 + 243 +* the measured humidity is greater than the “Maximum (water) humidity” value during the “Delay before setting the error” time. 244 + 245 +Conditions for removing the error: 246 + 247 +* the measured humidity is less than the “Tolerant humidity” value during the “Delay before clearing the error” time. 248 + 249 +(% class="box warningmessage" %) 250 +((( 251 +**If there is the “Water” error, the “Critical error” is generated and all relays open.** 252 +))) 253 + 199 199 == 3.6.9 Current sensor error == 200 200 256 +The board is implemented to check the current sensor connection circuits. The circuits are checked for breakage and short-circuit to the +5 V supply line. 257 + 258 +To change the test parameters of the current sensor connection circuits, select the menu "Protections → Current sensor error": 259 + 260 + 261 +In this section: 262 + 263 +* Enable – a flag to enable the protection; 264 +* Maximum voltage, V; 265 +* Minimum voltage, V; 266 +* Hysteresis voltage – a hysteresis value to clear the error, V; 267 +* Delay before setting the error, second; 268 +* Delay before clearing the error, second; 269 +* Lock the error until the device is reset. 270 + 271 +If there is an open or short circuit connection of a current sensor, the "Current sensor error" is generated. 272 + 273 +Error generation conditions: 274 + 275 +* the voltage in the signal line or zero level line of the current sensor is greater than the “Maximum voltage” value during the “Delay before setting the error” time; 276 +* the voltage in the signal line or zero level line of the current sensor is less than the “Minimum voltage” value during the “Delay before setting the error” time. 277 + 278 +Conditions for removing the error: 279 + 280 +* the voltage in the signal line or zero level line of the current sensor is in range from (Minimum voltage + Hysteresis voltage) to (Maximum voltage - Hysteresis voltage) during the “Delay before clearing the error” time. 281 + 282 +**If there is the “Current sensor error”, the “Critical error” is generated and all relays open.** 283 + 201 201 == 3.6.10 Short circuit protection == 202 202 203 203 == 3.6.11 Contactor high temperature protection ==