Details

Page properties
Content
... ... @@ -6,9 +6,8 @@
6 6  
7 7  [[Overcurrent protection settings>>image:1732211959984-118.png||data-xwiki-image-style-alignment="center" height="266" width="386"]]
8 8  
9 + In this section:
9 9  
10 -In this section:
11 -
12 12  * Enable – a flag to enable the protection;
13 13  * Maximum charging current, А;
14 14  * Tolerant charging current, А;
... ... @@ -32,7 +32,7 @@
32 32  
33 33  (% class="box infomessage" %)
34 34  (((
35 -If there is the "Overcurrent" error, the charging relay and discharging relay open.
34 +If there is the "Overcurrent" error, the charging and discharging relay open.
36 36  )))
37 37  
38 38  == 3.6.2 Undervoltage protection ==
... ... @@ -192,8 +192,34 @@
192 192  **If there is the "Battery cover error", the “Critical error” is generated and all relays open.**
193 193  )))
194 194  
195 -== 3.6.7 High humidity protection ==
194 +== 3.6.7 High humidity protection ==
196 196  
196 +The board can protect the battery from high humidity and water.
197 +
198 +To change the protection parameters of the battery from high humidity, select the menu "Protections → High humidity protection":
199 +
200 +In this section:
201 +
202 +* Enable – a flag to enable the protection;
203 +* Maximum humidty, RH%;
204 +* Tolerant humidty, RH%;
205 +* Delay before setting the error, second;
206 +* Delay before clearing the error, second;
207 +* Lock the error until the device is reset.
208 +
209 +As a result of the operation of the battery protection from high humidity, the "High humidity" error is generated.
210 +
211 +Error generation conditions:
212 +
213 +* the measured humidity is greater than “Maximum humidity” during the “Delay before setting the error” time.
214 +
215 +Conditions for removing the error:
216 +
217 +* the measured humidity is less than the “Tolerant humidity” during the “Delay before clearing the error” time.
218 +
219 +If there is the "High humidity" error, no action is taken. The error is indicative.