Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,9 +6,8 @@ 6 6 7 7 [[Overcurrent protection settings>>image:1732211959984-118.png||data-xwiki-image-style-alignment="center" height="266" width="386"]] 8 8 9 + In this section: 9 9 10 -In this section: 11 - 12 12 * Enable – a flag to enable the protection; 13 13 * Maximum charging current, А; 14 14 * Tolerant charging current, А; ... ... @@ -32,7 +32,7 @@ 32 32 33 33 (% class="box infomessage" %) 34 34 ((( 35 -If there is the "Overcurrent" error, the charging relay and discharging relay open.34 +If there is the "Overcurrent" error, the charging and discharging relay open. 36 36 ))) 37 37 38 38 == 3.6.2 Undervoltage protection == ... ... @@ -128,7 +128,8 @@ 128 128 129 129 (% class="box infomessage" %) 130 130 ((( 131 -If there is the "Low CH temperature" error, the charging relay opens. If there is the "Low DCH temperature" error, the discharging relay opens. 130 +If there is the "Low CH temperature" error, the charging relay opens. 131 +If there is the "Low DCH temperature" error, the discharging relay opens. 132 132 ))) 133 133 134 134 == 3.6.5 High temperature protection == ... ... @@ -137,6 +137,7 @@ 137 137 138 138 To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection": 139 139 140 + 140 140 In this section: 141 141 142 142 * Enable – a flag to enable the protection; ... ... @@ -166,8 +166,58 @@ 166 166 167 167 == 3.6.6 Battery cover protection == 168 168 169 - ==3.6.7High humidity protection==170 +To change the protection parameters from opening the battery cover, select the menu "Protections → Battery cover protection": 170 170 172 +In this section: 173 + 174 +* Enable – a flag to enable the protection; 175 +* Delay before setting the error, second; 176 +* Delay before clearing the error, second; 177 +* Lock the error until the device is reset. 178 + 179 +As a result of the operation of the protection against opening the battery cover, the “Battery cover error” is generated. 180 + 181 +Error generation conditions: 182 + 183 +* there is a signal from the battery cover during the “Delay before setting the error” time. 184 + 185 +Conditions for removing the error: 186 + 187 +* no signal from the battery cover during the “Delay before clearing the error” time. 188 + 189 +(% class="box warningmessage" %) 190 +((( 191 +**If there is the "Battery cover error", the “Critical error” is generated and all relays open.** 192 +))) 193 + 194 +== 3.6.7 High humidity protection == 195 + 196 +The board can protect the battery from high humidity and water. 197 + 198 +To change the protection parameters of the battery from high humidity, select the menu "Protections → High humidity protection": 199 + 200 +In this section: 201 + 202 +* Enable – a flag to enable the protection; 203 +* Maximum humidty, RH%; 204 +* Tolerant humidty, RH%; 205 +* Delay before setting the error, second; 206 +* Delay before clearing the error, second; 207 +* Lock the error until the device is reset. 208 + 209 +As a result of the operation of the battery protection from high humidity, the "High humidity" error is generated. 210 + 211 +Error generation conditions: 212 + 213 +* the measured humidity is greater than “Maximum humidity” during the “Delay before setting the error” time. 214 + 215 +Conditions for removing the error: 216 + 217 +* the measured humidity is less than the “Tolerant humidity” during the “Delay before clearing the error” time. 218 + 219 +If there is the "High humidity" error, no action is taken. The error is indicative. 220 + 221 + 171 171 == 3.6.8 Water protection == 172 172 173 173 == 3.6.9 Current sensor error ==