Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -128,7 +128,8 @@ 128 128 129 129 (% class="box infomessage" %) 130 130 ((( 131 -If there is the "Low CH temperature" error, the charging relay opens. If there is the "Low DCH temperature" error, the discharging relay opens. 131 +If there is the "Low CH temperature" error, the charging relay opens. 132 +If there is the "Low DCH temperature" error, the discharging relay opens. 132 132 ))) 133 133 134 134 == 3.6.5 High temperature protection == ... ... @@ -137,6 +137,7 @@ 137 137 138 138 To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection": 139 139 141 + 140 140 In this section: 141 141 142 142 * Enable – a flag to enable the protection; ... ... @@ -166,6 +166,30 @@ 166 166 167 167 == 3.6.6 Battery cover protection == 168 168 171 +To change the protection parameters from opening the battery cover, select the menu "Protections → Battery cover protection": 172 + 173 +In this section: 174 + 175 +* Enable – a flag to enable the protection; 176 +* Delay before setting the error, second; 177 +* Delay before clearing the error, second; 178 +* Lock the error until the device is reset. 179 + 180 +As a result of the operation of the protection against opening the battery cover, the “Battery cover error” is generated. 181 + 182 +Error generation conditions: 183 + 184 +* there is a signal from the battery cover during the “Delay before setting the error” time. 185 + 186 +Conditions for removing the error: 187 + 188 +* no signal from the battery cover during the “Delay before clearing the error” time. 189 + 190 +(% class="box warningmessage" %) 191 +((( 192 +**If there is the "Battery cover error", the “Critical error” is generated and all relays open.** 193 +))) 194 + 169 169 == 3.6.7 High humidity protection == 170 170 171 171 == 3.6.8 Water protection ==