Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -67,4 +67,90 @@ 67 67 If there is the "Undervoltage" error, the discharging relay opens. 68 68 ))) 69 69 70 - 70 +3.6.3 Overvoltage protection 71 + 72 +To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection": 73 + 74 +[[image:1732212357972-295.png]] 75 + 76 +In this section: 77 + 78 +* Enable – a flag to enable the protection; 79 +* Maximum cell voltage, V; 80 +* Tolerant cell voltage, V; 81 +* Delay before setting the error, second; 82 +* Delay before clearing the error, second; 83 +* Switch off the discharging relay on error – a flag to open the discharging relay when the "Overvoltage" error is generated; 84 +* Lock the error until the device is reset. 85 + 86 +As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. 87 + 88 +Error generation conditions: 89 + 90 +* the maximum voltage among all cells of the battery is greater than the “Maximum cell voltage” value for the “Delay before setting the error” time. 91 + 92 +Conditions for removing the error: 93 + 94 +* the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 95 + 96 +(% class="box infomessage" %) 97 +((( 98 +If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set). 99 +))) 100 + 101 +== 3.6.4 Low temperature protection == 102 + 103 + 104 +== 3.6.5 High temperature protection == 105 + 106 +== 3.6.6 Battery cover protection == 107 + 108 +== 3.6.7 High humidity protection == 109 + 110 +== 3.6.8 Water protection == 111 + 112 +== 3.6.9 Current sensor error == 113 + 114 +== 3.6.10 Short circuit protection == 115 + 116 +== 3.6.11 Contactor high temperature protection == 117 + 118 +== 3.6.12 Unallowable charging protection == 119 + 120 +== 3.6.13 Stuck contactor protection == 121 + 122 +== 3.6.14 Contactor feedback check == 123 + 124 +== 3.6.15 Charging contactor cycles protection == 125 + 126 +== 3.6.16 Discharging contactor cycles protection == 127 + 128 +== 3.6.17 Temperature sensor error == 129 + 130 +== 3.6.18 Logic high temperature protection == 131 + 132 +== 3.6.19 Logic offline protection == 133 + 134 +== 3.6.20 Cell count protection == 135 + 136 +== 3.6.21 Logic count protection == 137 + 138 +== 3.6.22 WDT protection == 139 + 140 +== 3.6.23 Insulation monitoring == 141 + 142 +== 3.6.24 Critical error parameters == 143 + 144 +== 3.6.25 General error parameters == 145 + 146 +== 3.6.26 Low SOC signal == 147 + 148 +== 3.6.27 High charging current signal == 149 + 150 +== 3.6.28 Heater control == 151 + 152 +== 3.6.29 Heater (AUX) control == 153 + 154 +== 3.6.30 Cooler control == 155 + 156 +== 3.6.31 Fault simulation ==