Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - xwiki:drafts.BMS Main 2\.1.configuration.WebHome1 +drafts.BMS Main 2\.1.3\. Configuration.WebHome - Content
-
... ... @@ -1,10 +1,16 @@ 1 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += Configuration = 3 + 4 +(% data-numbered-headings-start="6" style="--numbered-headings-start: 5;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 +== Battery protection == 6 + 1 1 The BMS Main 2.x board continuously monitors the state of the cells, BMS Logic boards, the external environment and, when detecting abnormalities, protects the battery and system components from damage. 2 2 3 -== 3.6.1Overcurrent protection ==9 +=== Overcurrent protection === 4 4 5 5 To change the current protection of the battery, select the menu "Protections → Overcurrent protection": 6 6 7 -[[image:1732211959984-118.png||data-xwiki-image-style-alignment="center" height="266" width="386"]] 13 +[[image:1732211959984-118.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="266" width="386"]] 8 8 9 9 In this section: 10 10 ... ... @@ -34,13 +34,13 @@ 34 34 If there is the "Overcurrent" error, the **charging **and **discharging **relay open. 35 35 ))) 36 36 37 -== 3.6.2Undervoltage protection ==43 +=== Undervoltage protection === 38 38 39 39 The board implements battery protection from too low or too high voltage on the cells. 40 40 41 41 To change the battery protection parameters from low voltage on the cells, select the menu "Protections → Undervoltage protection": 42 42 43 -[[image:1732212212350-294.png||data-xwiki-image-style-alignment="center" height="207" width="359"]] 49 +[[image:1732212212350-294.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="359"]] 44 44 45 45 In this section: 46 46 ... ... @@ -66,11 +66,11 @@ 66 66 If there is the "Undervoltage" error, the **discharging **relay opens. 67 67 ))) 68 68 69 -== 3.6.3Overvoltage protection ==75 +=== Overvoltage protection === 70 70 71 71 To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection": 72 72 73 -[[image:1732212357972-295.png||data-xwiki-image-style-alignment="center" height="218" width="338"]] 79 +[[image:1732212357972-295.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="218" width="338"]] 74 74 75 75 In this section: 76 76 ... ... @@ -97,13 +97,13 @@ 97 97 If there is the "Overvoltage" error, the **charging **relay and **discharging **relay opens (if the “Switch off the discharging relay on error” flag is set). 98 98 ))) 99 99 100 -== 3.6.4Low temperature protection ==106 +=== Low temperature protection === 101 101 102 102 The board implements battery protection from too low temperature. 103 103 104 104 To change the battery protection parameters from low temperature, select the menu "Protections → Low temperature protection": 105 105 106 -[[image:1732213953083-955.png||data-xwiki-image-style-alignment="center" height="237" width="338"]] 112 +[[image:1732213953083-955.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="338"]] 107 107 108 108 In this section: 109 109 ... ... @@ -132,13 +132,13 @@ 132 132 If there is the "Low DCH temperature" error, the **discharging **relay opens. 133 133 ))) 134 134 135 -== 3.6.5High temperature protection ==141 +=== High temperature protection === 136 136 137 137 The board implements battery protection from too high temperature. 138 138 139 139 To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection": 140 140 141 -[[image:1732213990755-759.png||data-xwiki-image-style-alignment="center" height="258" width="370"]] 147 +[[image:1732213990755-759.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="258" width="370"]] 142 142 143 143 In this section: 144 144 ... ... @@ -167,11 +167,11 @@ 167 167 If there is the "High DCH temperature" error, the **discharging **relay opens. 168 168 ))) 169 169 170 -== 3.6.6Battery cover protection ==176 +=== Battery cover protection === 171 171 172 172 To change the protection parameters from opening the battery cover, select the menu "Protections → Battery cover protection": 173 173 174 -[[image:1732214030014-281.png||data-xwiki-image-style-alignment="center" height="155" width="334"]] 180 +[[image:1732214030014-281.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="155" width="334"]] 175 175 176 176 In this section: 177 177 ... ... @@ -195,13 +195,13 @@ 195 195 If there is the "Battery cover error", the **“Critical error” **is generated and **all relays open.** 196 196 ))) 197 197 198 -== 3.6.7High humidity protection ==204 +=== High humidity protection === 199 199 200 200 The board can protect the battery from high humidity and water. 201 201 202 202 To change the protection parameters of the battery from high humidity, select the menu "Protections → High humidity protection": 203 203 204 -[[image:1732214076060-358.png||data-xwiki-image-style-alignment="center" height="185" width="321"]] 210 +[[image:1732214076060-358.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="185" width="321"]] 205 205 206 206 In this section: 207 207 ... ... @@ -227,11 +227,11 @@ 227 227 If there is the "High humidity" error, no action is taken. The error is indicative. 228 228 ))) 229 229 230 -== 3.6.8Water protection ==236 +=== Water protection === 231 231 232 232 To change the protection parameters of the battery from water, select the menu "Protections → Water protection": 233 233 234 -[[image:1732214111990-184.png||data-xwiki-image-style-alignment="center" height="199" width="340"]] 240 +[[image:1732214111990-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="199" width="340"]] 235 235 236 236 In this section: 237 237 ... ... @@ -257,13 +257,13 @@ 257 257 If there is the “Water” error,** **the **“Critical error”** is generated and **all relays open.** 258 258 ))) 259 259 260 -== 3.6.9Current sensor error ==266 +=== Current sensor error === 261 261 262 262 The board is implemented to check the current sensor connection circuits. The circuits are checked for breakage and short-circuit to the +5 V supply line. 263 263 264 264 To change the test parameters of the current sensor connection circuits, select the menu "Protections → Current sensor error": 265 265 266 -[[image:1732214146724-132.png||data-xwiki-image-style-alignment="center" height="438" width="365"]] 272 +[[image:1732214146724-132.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="438" width="365"]] 267 267 268 268 In this section: 269 269 ... ... @@ -291,13 +291,13 @@ 291 291 If there is the “Current sensor error”, the **“Critical error” **is generated and **all relays open.** 292 292 ))) 293 293 294 -== 3.6.10Short circuit protection ==300 +=== Short circuit protection === 295 295 296 296 The BMS implements a protection of power circuits (contactors, power cables) against overheating caused by the flow of high current for a long time. 297 297 298 298 To change the protection parameters from short circuit, select the menu "Protections → Short circuit protection": 299 299 300 -[[image:1732214207026-822.png||data-xwiki-image-style-alignment="center" height="528" width="371"]] 306 +[[image:1732214207026-822.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="528" width="371"]] 301 301 302 302 In this section: 303 303 ... ... @@ -325,13 +325,13 @@ 325 325 If there is the "Short circuit" error, the **charging **relay opens (the “Switch off the charging relay on error” flag is set) and the **discharging **relay opens (the “Switch off the discharging relay on error flag” is set). 326 326 ))) 327 327 328 -== 3.6.11Contactor high temperature protection ==334 +=== Contactor high temperature protection === 329 329 330 330 The BMS protects power contactors from overheating. To measure the temperature of the contactor, a thermistor is used, connected to the P13 connector of the board. Configuring of the analog input for temperature measurement is described in section Input signals. 331 331 332 332 To change the overheating protection parameters of power contactors, select the menu "Protections → Contactor high temperature protection": 333 333 334 -[[image:1732214237851-405.png||data-xwiki-image-style-alignment="center" height="234" width="336"]] 340 +[[image:1732214237851-405.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="234" width="336"]] 335 335 336 336 In this section: 337 337 ... ... @@ -359,13 +359,13 @@ 359 359 If there is the "Contactor high temperature" error, the **charging **relay opens (the “Switch off the charging relay on error” flag is set) and the **discharging **relay opens (the “Switch off the discharging relay on error flag” is set). 360 360 ))) 361 361 362 -== 3.6.12Unallowable charging protection ==368 +=== Unallowable charging protection === 363 363 364 364 The BMS can detect that the battery is charging through the discharging circuit and protectively open the discharging relay to prevent unallowable battery operation. 365 365 366 366 To change the parameters of the unallowable charging protection, select the menu "Protections → Unallowable charging protection": 367 367 368 -[[image:1732214272022-547.png||data-xwiki-image-style-alignment="center" height="145" width="312"]] 374 +[[image:1732214272022-547.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="145" width="312"]] 369 369 370 370 In this section: 371 371 ... ... @@ -389,13 +389,13 @@ 389 389 If there is the "Unallowable charging" error, the **discharging **relay opens. 390 390 ))) 391 391 392 -== 3.6.13Stuck contactor protection ==398 +=== Stuck contactor protection === 393 393 394 394 The BMS Main 2.x protects contactors against sticking. 395 395 396 396 To change the protection parameters against sticking, select the menu "Protections → Stuck contactor protection": 397 397 398 -[[image:1732214367207-318.png||data-xwiki-image-style-alignment="center" height="152" width="331"]] 404 +[[image:1732214367207-318.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="152" width="331"]] 399 399 400 400 In this section: 401 401 ... ... @@ -415,13 +415,13 @@ 415 415 If there is the “Stuck contactor error”, the **“Critical error” **is generated and **all relays open.** 416 416 ))) 417 417 418 -== 3.6.14Contactor feedback check ==424 +=== Contactor feedback check === 419 419 420 -The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see se ction426 +The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see [[3.3 Input and output signals>>path:/bin/view/drafts/BMS%20Main%202.1/3.%20Configuration/3.3%20Input%20and%20output%20signals/]]). 421 421 422 422 To change the contactor feedback check parameters, select the menu "Protections → Contactor feedback check": 423 423 424 -[[image:1732214400721-274.png||data-xwiki-image-style-alignment="center" height="150" width="323"]] 430 +[[image:1732214400721-274.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="150" width="323"]] 425 425 426 426 In this section: 427 427 ... ... @@ -439,13 +439,13 @@ 439 439 If there is the contactor feedback error, the **“Critical error” **is generated and **all relays open.** 440 440 ))) 441 441 442 -== 3.6.15Charging contactor cycles protection ==448 +=== Charging contactor cycles protection === 443 443 444 444 The BMS protects the charging contactor against frequent switching. 445 445 446 446 To change the protection parameters against high frequency switching of the charging contactor, select the menu "Protections → Charging contactor cycles protection": 447 447 448 -[[image:1732214432750-543.png||data-xwiki-image-style-alignment="center" height="260" width="336"]] 454 +[[image:1732214432750-543.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="260" width="336"]] 449 449 450 450 In this section: 451 451 ... ... @@ -472,13 +472,13 @@ 472 472 If there is the "CH contactor cycles error" error, the **charging **relay opens. 473 473 ))) 474 474 475 -== 3.6.16Discharging contactor cycles protection ==481 +=== Discharging contactor cycles protection === 476 476 477 477 The BMS protects the discharging contactor against frequent switching. 478 478 479 479 To change the protection parameters against high frequency switching of the discharging contactor, select the menu "Protections → Discharging contactor cycles protection": 480 480 481 -[[image:1732214468462-541.png||data-xwiki-image-style-alignment="center" height="269" width="346"]] 487 +[[image:1732214468462-541.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="269" width="346"]] 482 482 483 483 In this section: 484 484 ... ... @@ -505,13 +505,13 @@ 505 505 If there is the "DCH contactor cycles error" error, the **discharging **relay opens. 506 506 ))) 507 507 508 -== 3.6.17Temperature sensor error ==514 +=== Temperature sensor error === 509 509 510 510 The board is implemented to check the temperature sensors connection circuits. The circuits are checked for breakage and short-circuit. 511 511 512 512 To change the protection parameters of the temperature sensors circuits, select the menu "Protections → Temperature sensor error": 513 513 514 -[[image:1732214501360-654.png||data-xwiki-image-style-alignment="center" height="154" width="334"]] 520 +[[image:1732214501360-654.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="154" width="334"]] 515 515 516 516 In this section: 517 517 ... ... @@ -527,11 +527,11 @@ 527 527 If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error” **is generated and **all relays open.** 528 528 ))) 529 529 530 -== 3.6.18Logic high temperature protection ==536 +=== Logic high temperature protection === 531 531 532 532 To change the overheating protection parameters of BMS Logic boards, select the menu "Protections → Logic high temperature protection": 533 533 534 -[[image:1732214545352-111.png||data-xwiki-image-style-alignment="center" height="156" width="309"]] 540 +[[image:1732214545352-111.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="156" width="309"]] 535 535 536 536 In this section: 537 537 ... ... @@ -555,11 +555,11 @@ 555 555 Cell balancing is prohibited for overheated boards. 556 556 ))) 557 557 558 -== 3.6.19Logic offline protection ==564 +=== Logic offline protection === 559 559 560 560 To change the protection parameters from loss of communication with BMS Logic boards, select the menu "Protections → Logic offline protection": 561 561 562 -[[image:1732214579147-515.png||data-xwiki-image-style-alignment="center" height="107" width="204"]] 568 +[[image:1732214579147-515.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="107" width="204"]] 563 563 564 564 In this section: 565 565 ... ... @@ -581,11 +581,11 @@ 581 581 If there is the "Logic offline" error, the **“Critical error”** is generated and **all relays open.** 582 582 ))) 583 583 584 -== 3.6.20Cell count protection ==590 +=== Cell count protection === 585 585 586 586 To change the protection parameters from the mismatch of the number of cells to the set value, select the menu "Protections → Cell count protection": 587 587 588 -[[image:1732214641606-453.png||data-xwiki-image-style-alignment="center" height="178" width="341"]] 594 +[[image:1732214641606-453.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="178" width="341"]] 589 589 590 590 In this section: 591 591 ... ... @@ -610,11 +610,11 @@ 610 610 If there is the "Cell count error",** **the **“Critical error”** is generated and **all relays open.** 611 611 ))) 612 612 613 -== 3.6.21Logic count protection ==619 +=== Logic count protection === 614 614 615 615 To change the protection parameters from the mismatch of the number of BMS Logic boards to the set value, select the menu "Protections → Logic count protection": 616 616 617 -[[image:1732214675358-202.png||data-xwiki-image-style-alignment="center" height="163" width="230"]] 623 +[[image:1732214675358-202.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="230"]] 618 618 619 619 In this section: 620 620 ... ... @@ -638,13 +638,13 @@ 638 638 If there is the "Logic count error", the **“Critical error” **is generated and **all relays open.** 639 639 ))) 640 640 641 -== 3.6.22WDT protection ==647 +=== WDT protection === 642 642 643 643 If the BMS firmware hangs, the watchdog timer resets the board. The BMS can detect that the board was reset and generates the “WDT reset” error. 644 644 645 645 To change the parameters of the watchdog protection, select the menu "Protections → WDT protection": 646 646 647 -[[image:1732214703914-144.png||data-xwiki-image-style-alignment="center" height="127" width="323"]] 653 +[[image:1732214703914-144.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="323"]] 648 648 649 649 In this section: 650 650 ... ... @@ -661,13 +661,13 @@ 661 661 If there is the "WDT reset" error, the **“Critical error”** is generated and** all relays open.** 662 662 ))) 663 663 664 -== 3.6.23Insulation monitoring ==670 +=== Insulation monitoring === 665 665 666 666 BMS Main 2.x can detect a signal from an external insulation monitoring device (such as Bender IR155) to monitor the insulation quality. 667 667 668 668 To change the insulation monitoring parameters, select the menu "Protections → Insulation monitoring": 669 669 670 -[[image:1732214731490-961.png||data-xwiki-image-style-alignment="center" height="162" width="315"]] 676 +[[image:1732214731490-961.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="315"]] 671 671 672 672 In this section: 673 673 ... ... @@ -683,11 +683,11 @@ 683 683 If there is the "Insulation monitoring" error, the **“Critical error”** is generated and** all relays open.** 684 684 ))) 685 685 686 -== 3.6.24Critical error parameters ==692 +=== Critical error parameters === 687 687 688 688 To change the critical error parameters, select the menu "Protections → Critical error parameters": 689 689 690 -[[image:1732214761141-983.png||data-xwiki-image-style-alignment="center" height="158" width="348"]] 696 +[[image:1732214761141-983.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="348"]] 691 691 692 692 In this section: 693 693 ... ... @@ -722,11 +722,11 @@ 722 722 **If there is the “Critical error”, all relays open.** 723 723 ))) 724 724 725 -== 3.6.25General error parameters ==731 +=== General error parameters === 726 726 727 727 To change the general error parameters, select the menu "Protections → General error parameters": 728 728 729 -[[image:1732214987517-111.png||data-xwiki-image-style-alignment="center" height="535" width="349"]] 735 +[[image:1732214987517-111.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="535" width="349"]] 730 730 731 731 In this section: 732 732 ... ... @@ -745,11 +745,11 @@ 745 745 The "General error" is //indicative //and can be linked to any discrete output of the board. 746 746 ))) 747 747 748 -== 3.6.26Low SOC signal ==754 +=== Low SOC signal === 749 749 750 750 To change the parameters of the generation a signal about low battery level, select the menu "Protections → Low SOC signal": 751 751 752 -[[image:1732215174961-645.png||data-xwiki-image-style-alignment="center" height="186" width="325"]] 758 +[[image:1732215174961-645.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="186" width="325"]] 753 753 754 754 In this section: 755 755 ... ... @@ -773,11 +773,11 @@ 773 773 The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board. 774 774 ))) 775 775 776 -== 3.6.27High charging current signal ==782 +=== High charging current signal === 777 777 778 778 To change the parameters of the generation high-current signal, select the menu "Protections → High charging current signal": 779 779 780 -[[image:1732215211714-445.png||data-xwiki-image-style-alignment="center" height="181" width="322"]] 786 +[[image:1732215211714-445.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="181" width="322"]] 781 781 782 782 In this section: 783 783 ... ... @@ -801,11 +801,11 @@ 801 801 The "High charging current" signal is //indicative //and can be linked to any discrete output of the board. 802 802 ))) 803 803 804 -== 3.6.28Heater control ==810 +=== Heater control === 805 805 806 806 To change the parameters of the heater control algorithm, select the menu "Protections → Heater control": 807 807 808 -[[image:1732215252650-791.png||data-xwiki-image-style-alignment="center" height="233" width="370"]] 814 +[[image:1732215252650-791.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="233" width="370"]] 809 809 810 810 In this section: 811 811 ... ... @@ -832,11 +832,11 @@ 832 832 If there is the "Heater" signal, the **heater **relay closes and/or a signal is output to the corresponded digital output. 833 833 ))) 834 834 835 -== 3.6.29Heater (AUX) control ==841 +=== Heater (AUX) control === 836 836 837 837 To change the parameters of the auxiliary heater control algorithm, select the menu "Protections → Heater (AUX) control": 838 838 839 -[[image:1732215282135-420.png||data-xwiki-image-style-alignment="center" height="228" width="361"]] 845 +[[image:1732215282135-420.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="228" width="361"]] 840 840 841 841 In this section: 842 842 ... ... @@ -863,11 +863,11 @@ 863 863 If there is the "Heater (AUX)" signal, the **auxiliary heater **relay closes and/or a signal is output to the corresponded digital output. 864 864 ))) 865 865 866 -== 3.6.30Cooler control ==872 +=== Cooler control === 867 867 868 868 To change the parameters of the cooler control algorithm, select the menu "Protections → Cooler control": 869 869 870 -[[image:1732215313977-499.png||data-xwiki-image-style-alignment="center" height="219" width="348"]] 876 +[[image:1732215313977-499.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="219" width="348"]] 871 871 872 872 In this section: 873 873 ... ... @@ -894,12 +894,12 @@ 894 894 If there is the "Cooler" signal, the **cooler **relay closes and/or a signal is output to the corresponded digital output. 895 895 ))) 896 896 897 -== 3.6.31Fault simulation ==903 +=== Fault simulation === 898 898 899 899 The board provides the ability to manually generate error flags bypassing the protection algorithms. This functionality is intended for commissioning. 900 900 901 901 To simulate battery and BMS errors, select the menu "Protections → Fault simulation": 902 902 903 -[[image:1732215359330-850.png||data-xwiki-image-style-alignment="center" height="732" width="204"]] 909 +[[image:1732215359330-850.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="732" width="204"]] 904 904 905 905 To simulate errors, set the necessary flags and click on the "Save" button.