Changes for page 3.6 Battery protection

Last modified by Admin on 2025/04/09 12:25

From version 35.1
edited by Admin
on 2024/11/21 19:23
Change comment: There is no comment for this version
To version 33.8
edited by Admin
on 2024/11/21 19:07
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -34,7 +34,7 @@
34 34  If there is the "Overcurrent" error, the **charging **and **discharging **relay open.
35 35  )))
36 36  
37 -== 3.6.2 Undervoltage protection ==
37 +== 3.6.2 Undervoltage protection ==
38 38  
39 39  The board implements battery protection from too low or too high voltage on the cells.
40 40  
... ... @@ -66,7 +66,7 @@
66 66  If there is the "Undervoltage" error, the **discharging **relay opens.
67 67  )))
68 68  
69 -== 3.6.3 Overvoltage protection ==
69 +3.6.3 Overvoltage protection
70 70  
71 71  To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection":
72 72  
... ... @@ -658,7 +658,7 @@
658 658  
659 659  (% class="box warningmessage" %)
660 660  (((
661 -If there is the "WDT reset" error, the **“Critical error”** is generated and** all relays open.**
661 +If there is the "WDT reset" error, the **“Critical error”** is generated and** all relays open.**
662 662  )))
663 663  
664 664  == 3.6.23 Insulation monitoring ==
... ... @@ -678,11 +678,6 @@
678 678  
679 679  Error is set if corresponding discrete input is set up and it received logical zero.
680 680  
681 -(% class="box warningmessage" %)
682 -(((
683 -If there is the "Insulation monitoring" error, the **“Critical error”** is generated and** all relays open.**
684 -)))
685 -
686 686  == 3.6.24 Critical error parameters ==
687 687  
688 688  To change the critical error parameters, select the menu "Protections → Critical error parameters":
... ... @@ -707,13 +707,10 @@
707 707  * “No temp. sensors”;
708 708  * “Temp. sensor is shorted”;
709 709  * “Current sensor error”;
710 -* "Stuck contactor";
711 -* "Contactor feedback";
712 712  * “Shunt offline”;
713 713  * “Shunt error”;
714 714  * “Settings error”;
715 -* “WDT reset”
716 -* "Insulation monitoring".
708 +* “WDT reset”.
717 717  
718 718  The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
719 719