Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -356,7 +356,7 @@ 356 356 357 357 (% class="box infomessage" %) 358 358 ((( 359 -If there is the "Contactor high temperature" error, the **charging**relay opens (the “Switch off the charging relay on error” flag is set) and the**discharging**relay opens (the “Switch off the discharging relay on error flag” is set).359 +If there is the "Contactor high temperature" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 360 360 ))) 361 361 362 362 == 3.6.12 Unallowable charging protection == ... ... @@ -386,7 +386,7 @@ 386 386 387 387 (% class="box infomessage" %) 388 388 ((( 389 -If there is the "Unallowable charging" error, the **discharging**relay opens.389 +If there is the "Unallowable charging" error, the discharging relay opens. 390 390 ))) 391 391 392 392 == 3.6.13 Stuck contactor protection == ... ... @@ -410,11 +410,6 @@ 410 410 411 411 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 412 412 413 -(% class="box warningmessage" %) 414 -((( 415 -If there is the “Stuck contactor error”, the **“Critical error” **is generated and **all relays open.** 416 -))) 417 - 418 418 == 3.6.14 Contactor feedback check == 419 419 420 420 The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see section Input and output signals). ... ... @@ -434,11 +434,6 @@ 434 434 435 435 * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 436 436 437 -(% class="box warningmessage" %) 438 -((( 439 -If there is the contactor feedback error, the **“Critical error” **is generated and **all relays open.** 440 -))) 441 - 442 442 == 3.6.15 Charging contactor cycles protection == 443 443 444 444 The BMS protects the charging contactor against frequent switching. ... ... @@ -469,7 +469,7 @@ 469 469 470 470 (% class="box infomessage" %) 471 471 ((( 472 -If there is the "CH contactor cycles error" error, the **charging**relay opens.462 +If there is the "CH contactor cycles error" error, the charging relay opens. 473 473 ))) 474 474 475 475 == 3.6.16 Discharging contactor cycles protection == ... ... @@ -502,7 +502,7 @@ 502 502 503 503 (% class="box infomessage" %) 504 504 ((( 505 -If there is the "DCH contactor cycles error" error, the **discharging**relay opens.495 +If there is the "DCH contactor cycles error" error, the discharging relay opens. 506 506 ))) 507 507 508 508 == 3.6.17 Temperature sensor error == ... ... @@ -524,7 +524,7 @@ 524 524 525 525 (% class="box warningmessage" %) 526 526 ((( 527 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”**is generated and**all relays open.**517 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, **the “Critical error” is generated and all relays open.** 528 528 ))) 529 529 530 530 == 3.6.18 Logic high temperature protection == ... ... @@ -578,7 +578,7 @@ 578 578 579 579 (% class="box warningmessage" %) 580 580 ((( 581 -If there is the "Logic offline" error, the **“Critical error”**is generated and**all relays open.**571 +If there is the "Logic offline" error, **the “Critical error” is generated and all relays open.** 582 582 ))) 583 583 584 584 == 3.6.20 Cell count protection == ... ... @@ -607,7 +607,7 @@ 607 607 608 608 (% class="box warningmessage" %) 609 609 ((( 610 -If there is the "Cell count error",** **the**“Critical error”**is generated and**all relays open.**600 +If there is the "Cell count error",** the “Critical error” is generated and all relays open.** 611 611 ))) 612 612 613 613 == 3.6.21 Logic count protection == ... ... @@ -635,7 +635,7 @@ 635 635 636 636 (% class="box warningmessage" %) 637 637 ((( 638 -If there is the "Logic count error", the **“Critical error”**is generated and**all relays open.**628 +If there is the "Logic count error", **the “Critical error” is generated and all relays open.** 639 639 ))) 640 640 641 641 == 3.6.22 WDT protection == ... ... @@ -658,7 +658,7 @@ 658 658 659 659 (% class="box warningmessage" %) 660 660 ((( 661 -If there is the "WDT reset" error, the **“Critical error”**is generated and**all relays open.**651 +If there is the "WDT reset" error, **the “Critical error” is generated and all relays open.** 662 662 ))) 663 663 664 664 == 3.6.23 Insulation monitoring == ... ... @@ -678,11 +678,6 @@ 678 678 679 679 Error is set if corresponding discrete input is set up and it received logical zero. 680 680 681 -(% class="box warningmessage" %) 682 -((( 683 -If there is the "Insulation monitoring" error, the **“Critical error”** is generated and** all relays open.** 684 -))) 685 - 686 686 == 3.6.24 Critical error parameters == 687 687 688 688 To change the critical error parameters, select the menu "Protections → Critical error parameters": ... ... @@ -707,13 +707,10 @@ 707 707 * “No temp. sensors”; 708 708 * “Temp. sensor is shorted”; 709 709 * “Current sensor error”; 710 -* "Stuck contactor"; 711 -* "Contactor feedback"; 712 712 * “Shunt offline”; 713 713 * “Shunt error”; 714 714 * “Settings error”; 715 -* “WDT reset” 716 -* "Insulation monitoring". 698 +* “WDT reset”. 717 717 718 718 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 719 719 ... ... @@ -740,10 +740,7 @@ 740 740 741 741 The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time. 742 742 743 -(% class="box infomessage" %) 744 -((( 745 745 The "General error" is //indicative //and can be linked to any discrete output of the board. 746 -))) 747 747 748 748 == 3.6.26 Low SOC signal == 749 749 ... ... @@ -768,10 +768,7 @@ 768 768 769 769 * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 770 770 771 -(% class="box infomessage" %) 772 -((( 773 773 The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board. 774 -))) 775 775 776 776 == 3.6.27 High charging current signal == 777 777 ... ... @@ -796,10 +796,7 @@ 796 796 797 797 * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 798 798 799 -(% class="box infomessage" %) 800 -((( 801 801 The "High charging current" signal is //indicative //and can be linked to any discrete output of the board. 802 -))) 803 803 804 804 == 3.6.28 Heater control == 805 805 ... ... @@ -829,7 +829,7 @@ 829 829 830 830 (% class="box infomessage" %) 831 831 ((( 832 -If there is the "Heater" signal, the **heater**relay closes and/or a signal is output to the corresponded digital output.805 +If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 833 833 ))) 834 834 835 835 == 3.6.29 Heater (AUX) control == ... ... @@ -860,7 +860,7 @@ 860 860 861 861 (% class="box infomessage" %) 862 862 ((( 863 -If there is the "Heater (AUX)" signal, the **auxiliary heater**relay closes and/or a signal is output to the corresponded digital output.836 +If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output. 864 864 ))) 865 865 866 866 == 3.6.30 Cooler control == ... ... @@ -891,7 +891,7 @@ 891 891 892 892 (% class="box infomessage" %) 893 893 ((( 894 -If there is the "Cooler" signal, the **cooler**relay closes and/or a signal is output to the corresponded digital output.867 +If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output. 895 895 ))) 896 896 897 897 == 3.6.31 Fault simulation ==