Changes for page 3.6 Battery protection

Last modified by Admin on 2025/04/09 12:25

From version 33.8
edited by Admin
on 2024/11/21 19:07
Change comment: There is no comment for this version
To version 35.3
edited by Admin
on 2024/11/22 15:12
Change comment: Update document after refactoring.

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -drafts.bms-main-2-1.configuration.WebHome
1 +drafts.bms-main-2.configuration.WebHome
Content
... ... @@ -34,7 +34,7 @@
34 34  If there is the "Overcurrent" error, the **charging **and **discharging **relay open.
35 35  )))
36 36  
37 -== 3.6.2 Undervoltage protection ==
37 +== 3.6.2 Undervoltage protection ==
38 38  
39 39  The board implements battery protection from too low or too high voltage on the cells.
40 40  
... ... @@ -66,7 +66,7 @@
66 66  If there is the "Undervoltage" error, the **discharging **relay opens.
67 67  )))
68 68  
69 -3.6.3 Overvoltage protection
69 +== 3.6.3 Overvoltage protection ==
70 70  
71 71  To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection":
72 72  
... ... @@ -658,7 +658,7 @@
658 658  
659 659  (% class="box warningmessage" %)
660 660  (((
661 -If there is the "WDT reset" error, the **“Critical error”** is generated and** all relays open.**
661 +If there is the "WDT reset" error, the **“Critical error”** is generated and** all relays open.**
662 662  )))
663 663  
664 664  == 3.6.23 Insulation monitoring ==
... ... @@ -678,6 +678,11 @@
678 678  
679 679  Error is set if corresponding discrete input is set up and it received logical zero.
680 680  
681 +(% class="box warningmessage" %)
682 +(((
683 +If there is the "Insulation monitoring" error, the **“Critical error”** is generated and** all relays open.**
684 +)))
685 +
681 681  == 3.6.24 Critical error parameters ==
682 682  
683 683  To change the critical error parameters, select the menu "Protections → Critical error parameters":
... ... @@ -702,10 +702,13 @@
702 702  * “No temp. sensors”;
703 703  * “Temp. sensor is shorted”;
704 704  * “Current sensor error”;
710 +* "Stuck contactor";
711 +* "Contactor feedback";
705 705  * “Shunt offline”;
706 706  * “Shunt error”;
707 707  * “Settings error”;
708 -* “WDT reset”.
715 +* “WDT reset”
716 +* "Insulation monitoring".
709 709  
710 710  The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
711 711