Changes for page 3.6 Battery protection

Last modified by Admin on 2025/04/09 12:25

From version 33.8
edited by Admin
on 2024/11/21 19:07
Change comment: There is no comment for this version
To version 33.5
edited by Admin
on 2024/11/21 19:00
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -410,10 +410,6 @@
410 410  
411 411  * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set.
412 412  
413 -(% class="box warningmessage" %)
414 -(((
415 -If there is the “Stuck contactor error”, the **“Critical error” **is generated and **all relays open.**
416 -)))
417 417  
418 418  == 3.6.14 Contactor feedback check ==
419 419  
... ... @@ -434,10 +434,6 @@
434 434  
435 435  * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value.
436 436  
437 -(% class="box warningmessage" %)
438 -(((
439 -If there is the contactor feedback error, the **“Critical error” **is generated and **all relays open.**
440 -)))
441 441  
442 442  == 3.6.15 Charging contactor cycles protection ==
443 443  
... ... @@ -524,7 +524,7 @@
524 524  
525 525  (% class="box warningmessage" %)
526 526  (((
527 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error” **is generated and **all relays open.**
519 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, **the “Critical error” is generated and all relays open.**
528 528  )))
529 529  
530 530  == 3.6.18 Logic high temperature protection ==
... ... @@ -578,7 +578,7 @@
578 578  
579 579  (% class="box warningmessage" %)
580 580  (((
581 -If there is the "Logic offline" error, the **“Critical error”** is generated and **all relays open.**
573 +If there is the "Logic offline" error, **the “Critical error” is generated and all relays open.**
582 582  )))
583 583  
584 584  == 3.6.20 Cell count protection ==
... ... @@ -607,7 +607,7 @@
607 607  
608 608  (% class="box warningmessage" %)
609 609  (((
610 -If there is the "Cell count error",** **the **“Critical error”** is generated and **all relays open.**
602 +If there is the "Cell count error",** the “Critical error” is generated and all relays open.**
611 611  )))
612 612  
613 613  == 3.6.21 Logic count protection ==
... ... @@ -635,7 +635,7 @@
635 635  
636 636  (% class="box warningmessage" %)
637 637  (((
638 -If there is the "Logic count error", the **“Critical error” **is generated and **all relays open.**
630 +If there is the "Logic count error", **the “Critical error” is generated and all relays open.**
639 639  )))
640 640  
641 641  == 3.6.22 WDT protection ==
... ... @@ -658,7 +658,7 @@
658 658  
659 659  (% class="box warningmessage" %)
660 660  (((
661 -If there is the "WDT reset" error, the **“Critical error”** is generated and** all relays open.**
653 +If there is the "WDT reset" error, **the “Critical error” is generated and all relays open.**
662 662  )))
663 663  
664 664  == 3.6.23 Insulation monitoring ==
... ... @@ -732,10 +732,7 @@
732 732  
733 733  The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time.
734 734  
735 -(% class="box infomessage" %)
736 -(((
737 737  The "General error" is //indicative //and can be linked to any discrete output of the board.
738 -)))
739 739  
740 740  == 3.6.26 Low SOC signal ==
741 741  
... ... @@ -760,10 +760,7 @@
760 760  
761 761  * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time.
762 762  
763 -(% class="box infomessage" %)
764 -(((
765 765  The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board.
766 -)))
767 767  
768 768  == 3.6.27 High charging current signal ==
769 769  
... ... @@ -788,10 +788,7 @@
788 788  
789 789  * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time.
790 790  
791 -(% class="box infomessage" %)
792 -(((
793 793  The "High charging current" signal is //indicative //and can be linked to any discrete output of the board.
794 -)))
795 795  
796 796  == 3.6.28 Heater control ==
797 797  
... ... @@ -821,7 +821,7 @@
821 821  
822 822  (% class="box infomessage" %)
823 823  (((
824 -If there is the "Heater" signal, the **heater **relay closes and/or a signal is output to the corresponded digital output.
807 +If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output.
825 825  )))
826 826  
827 827  == 3.6.29 Heater (AUX) control ==
... ... @@ -852,7 +852,7 @@
852 852  
853 853  (% class="box infomessage" %)
854 854  (((
855 -If there is the "Heater (AUX)" signal, the **auxiliary heater **relay closes and/or a signal is output to the corresponded digital output.
838 +If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output.
856 856  )))
857 857  
858 858  == 3.6.30 Cooler control ==
... ... @@ -883,7 +883,7 @@
883 883  
884 884  (% class="box infomessage" %)
885 885  (((
886 -If there is the "Cooler" signal, the **cooler **relay closes and/or a signal is output to the corresponded digital output.
869 +If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output.
887 887  )))
888 888  
889 889  == 3.6.31 Fault simulation ==