Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -31,7 +31,7 @@ 31 31 32 32 (% class="box infomessage" %) 33 33 ((( 34 -If there is the "Overcurrent" error, the **charging**and**discharging**relay open.34 +If there is the "Overcurrent" error, the charging and discharging relay open. 35 35 ))) 36 36 37 37 == 3.6.2 Undervoltage protection == ... ... @@ -63,7 +63,7 @@ 63 63 64 64 (% class="box infomessage" %) 65 65 ((( 66 -If there is the "Undervoltage" error, the **discharging**relay opens.66 +If there is the "Undervoltage" error, the discharging relay opens. 67 67 ))) 68 68 69 69 3.6.3 Overvoltage protection ... ... @@ -94,7 +94,7 @@ 94 94 95 95 (% class="box infomessage" %) 96 96 ((( 97 -If there is the "Overvoltage" error, the **charging**relay and**discharging**relay opens (if the “Switch off the discharging relay on error” flag is set).97 +If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set). 98 98 ))) 99 99 100 100 == 3.6.4 Low temperature protection == ... ... @@ -128,8 +128,8 @@ 128 128 129 129 (% class="box infomessage" %) 130 130 ((( 131 -If there is the "Low CH temperature" error, the **charging**relay opens.132 -If there is the "Low DCH temperature" error, the **discharging**relay opens.131 +If there is the "Low CH temperature" error, the charging relay opens. 132 +If there is the "Low DCH temperature" error, the discharging relay opens. 133 133 ))) 134 134 135 135 == 3.6.5 High temperature protection == ... ... @@ -163,8 +163,8 @@ 163 163 164 164 (% class="box infomessage" %) 165 165 ((( 166 -If there is the "High CH temperature" error, the **charging**relay opens.167 -If there is the "High DCH temperature" error, the **discharging**relay opens.166 +If there is the "High CH temperature" error, the charging relay opens. 167 +If there is the "High DCH temperature" error, the discharging relay opens. 168 168 ))) 169 169 170 170 == 3.6.6 Battery cover protection == ... ... @@ -192,7 +192,7 @@ 192 192 193 193 (% class="box warningmessage" %) 194 194 ((( 195 -If there is the "Battery cover error", the **“Critical error”**is generated and**all relays open.**195 +**If there is the "Battery cover error", the “Critical error” is generated and all relays open.** 196 196 ))) 197 197 198 198 == 3.6.7 High humidity protection == ... ... @@ -254,7 +254,7 @@ 254 254 255 255 (% class="box warningmessage" %) 256 256 ((( 257 -If there is the “Water” error, ****the**“Critical error”**is generated and**all relays open.**257 +**If there is the “Water” error, the “Critical error” is generated and all relays open.** 258 258 ))) 259 259 260 260 == 3.6.9 Current sensor error == ... ... @@ -288,7 +288,7 @@ 288 288 289 289 (% class="box warningmessage" %) 290 290 ((( 291 -If there is the “Current sensor error”, the **“Critical error”**is generated and**all relays open.**291 +**If there is the “Current sensor error”, the “Critical error” is generated and all relays open.** 292 292 ))) 293 293 294 294 == 3.6.10 Short circuit protection == ... ... @@ -322,7 +322,7 @@ 322 322 323 323 (% class="box infomessage" %) 324 324 ((( 325 -If there is the "Short circuit" error, the **charging**relay opens (the “Switch off the charging relay on error” flag is set) and the**discharging**relay opens (the “Switch off the discharging relay on error flag” is set).325 +If there is the "Short circuit" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 326 326 ))) 327 327 328 328 == 3.6.11 Contactor high temperature protection == ... ... @@ -356,7 +356,7 @@ 356 356 357 357 (% class="box infomessage" %) 358 358 ((( 359 -If there is the "Contactor high temperature" error, the **charging**relay opens (the “Switch off the charging relay on error” flag is set) and the**discharging**relay opens (the “Switch off the discharging relay on error flag” is set).359 +If there is the "Contactor high temperature" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 360 360 ))) 361 361 362 362 == 3.6.12 Unallowable charging protection == ... ... @@ -386,7 +386,7 @@ 386 386 387 387 (% class="box infomessage" %) 388 388 ((( 389 -If there is the "Unallowable charging" error, the **discharging**relay opens.389 +If there is the "Unallowable charging" error, the discharging relay opens. 390 390 ))) 391 391 392 392 == 3.6.13 Stuck contactor protection == ... ... @@ -410,11 +410,6 @@ 410 410 411 411 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 412 412 413 -(% class="box warningmessage" %) 414 -((( 415 -If there is the “Stuck contactor error”, the **“Critical error” **is generated and **all relays open.** 416 -))) 417 - 418 418 == 3.6.14 Contactor feedback check == 419 419 420 420 The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see section Input and output signals). ... ... @@ -434,11 +434,6 @@ 434 434 435 435 * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 436 436 437 -(% class="box warningmessage" %) 438 -((( 439 -If there is the contactor feedback error, the **“Critical error” **is generated and **all relays open.** 440 -))) 441 - 442 442 == 3.6.15 Charging contactor cycles protection == 443 443 444 444 The BMS protects the charging contactor against frequent switching. ... ... @@ -469,7 +469,7 @@ 469 469 470 470 (% class="box infomessage" %) 471 471 ((( 472 -If there is the "CH contactor cycles error" error, the **charging**relay opens.462 +If there is the "CH contactor cycles error" error, the charging relay opens. 473 473 ))) 474 474 475 475 == 3.6.16 Discharging contactor cycles protection == ... ... @@ -502,7 +502,7 @@ 502 502 503 503 (% class="box infomessage" %) 504 504 ((( 505 -If there is the "DCH contactor cycles error" error, the **discharging**relay opens.495 +If there is the "DCH contactor cycles error" error, the discharging relay opens. 506 506 ))) 507 507 508 508 == 3.6.17 Temperature sensor error == ... ... @@ -524,7 +524,7 @@ 524 524 525 525 (% class="box warningmessage" %) 526 526 ((( 527 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”**is generated and**all relays open.**517 +**If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the “Critical error” is generated and all relays open.** 528 528 ))) 529 529 530 530 == 3.6.18 Logic high temperature protection == ... ... @@ -552,7 +552,7 @@ 552 552 553 553 (% class="box infomessage" %) 554 554 ((( 555 -Cell balancing is prohibited for overheated boards. 545 +**Cell balancing is prohibited for overheated boards.** 556 556 ))) 557 557 558 558 == 3.6.19 Logic offline protection == ... ... @@ -578,7 +578,7 @@ 578 578 579 579 (% class="box warningmessage" %) 580 580 ((( 581 -If there is the "Logic offline" error, the **“Critical error”**is generated and**all relays open.**571 +**If there is the "Logic offline" error, the “Critical error” is generated and all relays open.** 582 582 ))) 583 583 584 584 == 3.6.20 Cell count protection == ... ... @@ -607,7 +607,7 @@ 607 607 608 608 (% class="box warningmessage" %) 609 609 ((( 610 -If there is the "Cell count error", ****the**“Critical error”**is generated and**all relays open.**600 +**If there is the "Cell count error", the “Critical error” is generated and all relays open.** 611 611 ))) 612 612 613 613 == 3.6.21 Logic count protection == ... ... @@ -635,7 +635,7 @@ 635 635 636 636 (% class="box warningmessage" %) 637 637 ((( 638 -If there is the "Logic count error", the **“Critical error”**is generated and**all relays open.**628 +**If there is the "Logic count error", the “Critical error” is generated and all relays open.** 639 639 ))) 640 640 641 641 == 3.6.22 WDT protection == ... ... @@ -658,7 +658,7 @@ 658 658 659 659 (% class="box warningmessage" %) 660 660 ((( 661 -If there is the "WDT reset" error, the **“Critical error”**is generated and**all relays open.**651 +**If there is the "WDT reset" error, the “Critical error” is generated and all relays open.** 662 662 ))) 663 663 664 664 == 3.6.23 Insulation monitoring == ... ... @@ -732,10 +732,7 @@ 732 732 733 733 The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time. 734 734 735 -(% class="box infomessage" %) 736 -((( 737 737 The "General error" is //indicative //and can be linked to any discrete output of the board. 738 -))) 739 739 740 740 == 3.6.26 Low SOC signal == 741 741 ... ... @@ -760,10 +760,7 @@ 760 760 761 761 * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 762 762 763 -(% class="box infomessage" %) 764 -((( 765 765 The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board. 766 -))) 767 767 768 768 == 3.6.27 High charging current signal == 769 769 ... ... @@ -788,10 +788,7 @@ 788 788 789 789 * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 790 790 791 -(% class="box infomessage" %) 792 -((( 793 793 The "High charging current" signal is //indicative //and can be linked to any discrete output of the board. 794 -))) 795 795 796 796 == 3.6.28 Heater control == 797 797 ... ... @@ -821,7 +821,7 @@ 821 821 822 822 (% class="box infomessage" %) 823 823 ((( 824 -If there is the "Heater" signal, the **heater**relay closes and/or a signal is output to the corresponded digital output.805 +If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 825 825 ))) 826 826 827 827 == 3.6.29 Heater (AUX) control == ... ... @@ -852,7 +852,7 @@ 852 852 853 853 (% class="box infomessage" %) 854 854 ((( 855 -If there is the "Heater (AUX)" signal, the **auxiliary heater**relay closes and/or a signal is output to the corresponded digital output.836 +If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output. 856 856 ))) 857 857 858 858 == 3.6.30 Cooler control == ... ... @@ -859,7 +859,7 @@ 859 859 860 860 To change the parameters of the cooler control algorithm, select the menu "Protections → Cooler control": 861 861 862 -[[Cooler control settings>>image:1732215313977-499.png||data-xwiki-image-style-alignment="center" height=" 219" width="348"]]843 +[[Cooler control settings>>image:1732215313977-499.png||data-xwiki-image-style-alignment="center" height="198" width="315"]] 863 863 864 864 In this section: 865 865 ... ... @@ -883,7 +883,7 @@ 883 883 884 884 (% class="box infomessage" %) 885 885 ((( 886 -If there is the "Cooler" signal, the **cooler**relay closes and/or a signal is output to the corresponded digital output.867 +If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output. 887 887 ))) 888 888 889 889 == 3.6.31 Fault simulation == ... ... @@ -892,7 +892,6 @@ 892 892 893 893 To simulate battery and BMS errors, select the menu "Protections → Fault simulation": 894 894 895 -[[Fault simulation settings>>image:1732215359330-850.png||data-xwiki-image-style-alignment="center" height="732" width="204"]] 896 896 897 897 In this section: 898 898