Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -34,7 +34,7 @@ 34 34 If there is the "Overcurrent" error, the **charging **and **discharging **relay open. 35 35 ))) 36 36 37 -== 37 +== 3.6.2 Undervoltage protection == 38 38 39 39 The board implements battery protection from too low or too high voltage on the cells. 40 40 ... ... @@ -66,7 +66,7 @@ 66 66 If there is the "Undervoltage" error, the **discharging **relay opens. 67 67 ))) 68 68 69 -3.6.3 Overvoltage protection 69 +== 3.6.3 Overvoltage protection == 70 70 71 71 To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection": 72 72 ... ... @@ -434,6 +434,10 @@ 434 434 435 435 * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 436 436 437 +(% class="box warningmessage" %) 438 +((( 439 +If there is the contactor feedback error, the **“Critical error” **is generated and **all relays open.** 440 +))) 437 437 438 438 == 3.6.15 Charging contactor cycles protection == 439 439 ... ... @@ -654,7 +654,7 @@ 654 654 655 655 (% class="box warningmessage" %) 656 656 ((( 657 -If there is the "WDT reset" error, the **“Critical error”** is generated and** 661 +If there is the "WDT reset" error, the **“Critical error”** is generated and** all relays open.** 658 658 ))) 659 659 660 660 == 3.6.23 Insulation monitoring == ... ... @@ -674,6 +674,11 @@ 674 674 675 675 Error is set if corresponding discrete input is set up and it received logical zero. 676 676 681 +(% class="box warningmessage" %) 682 +((( 683 +If there is the "Insulation monitoring" error, the **“Critical error”** is generated and** all relays open.** 684 +))) 685 + 677 677 == 3.6.24 Critical error parameters == 678 678 679 679 To change the critical error parameters, select the menu "Protections → Critical error parameters": ... ... @@ -698,10 +698,13 @@ 698 698 * “No temp. sensors”; 699 699 * “Temp. sensor is shorted”; 700 700 * “Current sensor error”; 710 +* "Stuck contactor"; 711 +* "Contactor feedback"; 701 701 * “Shunt offline”; 702 702 * “Shunt error”; 703 703 * “Settings error”; 704 -* “WDT reset”. 715 +* “WDT reset” 716 +* "Insulation monitoring". 705 705 706 706 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 707 707