... ... @@ -434,6 +434,10 @@
434 434  
435 435  * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value.
436 436  
437 +(% class="box warningmessage" %)
438 +(((
439 +If there is the contactor feedback error, the **“Critical error” **is generated and **all relays open.**
440 +)))
437 437  
438 438  == 3.6.15 Charging contactor cycles protection ==
439 439