Changes for page 3.6 Battery protection

Last modified by Admin on 2025/04/09 12:25

From version 33.7
edited by Admin
on 2024/11/21 19:03
Change comment: There is no comment for this version
To version 33.5
edited by Admin
on 2024/11/21 19:00
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -410,10 +410,6 @@
410 410  
411 411  * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set.
412 412  
413 -(% class="box warningmessage" %)
414 -(((
415 -If there is the “Stuck contactor error”, the **“Critical error” **is generated and **all relays open.**
416 -)))
417 417  
418 418  == 3.6.14 Contactor feedback check ==
419 419  
... ... @@ -520,7 +520,7 @@
520 520  
521 521  (% class="box warningmessage" %)
522 522  (((
523 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error” **is generated and **all relays open.**
519 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, **the “Critical error” is generated and all relays open.**
524 524  )))
525 525  
526 526  == 3.6.18 Logic high temperature protection ==
... ... @@ -574,7 +574,7 @@
574 574  
575 575  (% class="box warningmessage" %)
576 576  (((
577 -If there is the "Logic offline" error, the **“Critical error”** is generated and **all relays open.**
573 +If there is the "Logic offline" error, **the “Critical error” is generated and all relays open.**
578 578  )))
579 579  
580 580  == 3.6.20 Cell count protection ==
... ... @@ -603,7 +603,7 @@
603 603  
604 604  (% class="box warningmessage" %)
605 605  (((
606 -If there is the "Cell count error",** **the **“Critical error”** is generated and **all relays open.**
602 +If there is the "Cell count error",** the “Critical error” is generated and all relays open.**
607 607  )))
608 608  
609 609  == 3.6.21 Logic count protection ==
... ... @@ -631,7 +631,7 @@
631 631  
632 632  (% class="box warningmessage" %)
633 633  (((
634 -If there is the "Logic count error", the **“Critical error” **is generated and **all relays open.**
630 +If there is the "Logic count error", **the “Critical error” is generated and all relays open.**
635 635  )))
636 636  
637 637  == 3.6.22 WDT protection ==
... ... @@ -654,7 +654,7 @@
654 654  
655 655  (% class="box warningmessage" %)
656 656  (((
657 -If there is the "WDT reset" error, the **“Critical error”** is generated and** all relays open.**
653 +If there is the "WDT reset" error, **the “Critical error” is generated and all relays open.**
658 658  )))
659 659  
660 660  == 3.6.23 Insulation monitoring ==
... ... @@ -728,10 +728,7 @@
728 728  
729 729  The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time.
730 730  
731 -(% class="box infomessage" %)
732 -(((
733 733  The "General error" is //indicative //and can be linked to any discrete output of the board.
734 -)))
735 735  
736 736  == 3.6.26 Low SOC signal ==
737 737  
... ... @@ -756,10 +756,7 @@
756 756  
757 757  * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time.
758 758  
759 -(% class="box infomessage" %)
760 -(((
761 761  The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board.
762 -)))
763 763  
764 764  == 3.6.27 High charging current signal ==
765 765  
... ... @@ -784,10 +784,7 @@
784 784  
785 785  * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time.
786 786  
787 -(% class="box infomessage" %)
788 -(((
789 789  The "High charging current" signal is //indicative //and can be linked to any discrete output of the board.
790 -)))
791 791  
792 792  == 3.6.28 Heater control ==
793 793  
... ... @@ -817,7 +817,7 @@
817 817  
818 818  (% class="box infomessage" %)
819 819  (((
820 -If there is the "Heater" signal, the **heater **relay closes and/or a signal is output to the corresponded digital output.
807 +If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output.
821 821  )))
822 822  
823 823  == 3.6.29 Heater (AUX) control ==
... ... @@ -848,7 +848,7 @@
848 848  
849 849  (% class="box infomessage" %)
850 850  (((
851 -If there is the "Heater (AUX)" signal, the **auxiliary heater **relay closes and/or a signal is output to the corresponded digital output.
838 +If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output.
852 852  )))
853 853  
854 854  == 3.6.30 Cooler control ==
... ... @@ -879,7 +879,7 @@
879 879  
880 880  (% class="box infomessage" %)
881 881  (((
882 -If there is the "Cooler" signal, the **cooler **relay closes and/or a signal is output to the corresponded digital output.
869 +If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output.
883 883  )))
884 884  
885 885  == 3.6.31 Fault simulation ==