Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -410,10 +410,6 @@ 410 410 411 411 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 412 412 413 -(% class="box warningmessage" %) 414 -((( 415 -If there is the “Stuck contactor error”, the **“Critical error” **is generated and **all relays open.** 416 -))) 417 417 418 418 == 3.6.14 Contactor feedback check == 419 419 ... ... @@ -520,7 +520,7 @@ 520 520 521 521 (% class="box warningmessage" %) 522 522 ((( 523 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”**is generated and**all relays open.**519 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, **the “Critical error” is generated and all relays open.** 524 524 ))) 525 525 526 526 == 3.6.18 Logic high temperature protection == ... ... @@ -574,7 +574,7 @@ 574 574 575 575 (% class="box warningmessage" %) 576 576 ((( 577 -If there is the "Logic offline" error, the **“Critical error”**is generated and**all relays open.**573 +If there is the "Logic offline" error, **the “Critical error” is generated and all relays open.** 578 578 ))) 579 579 580 580 == 3.6.20 Cell count protection == ... ... @@ -603,7 +603,7 @@ 603 603 604 604 (% class="box warningmessage" %) 605 605 ((( 606 -If there is the "Cell count error",** **the**“Critical error”**is generated and**all relays open.**602 +If there is the "Cell count error",** the “Critical error” is generated and all relays open.** 607 607 ))) 608 608 609 609 == 3.6.21 Logic count protection == ... ... @@ -631,7 +631,7 @@ 631 631 632 632 (% class="box warningmessage" %) 633 633 ((( 634 -If there is the "Logic count error", the **“Critical error”**is generated and**all relays open.**630 +If there is the "Logic count error", **the “Critical error” is generated and all relays open.** 635 635 ))) 636 636 637 637 == 3.6.22 WDT protection == ... ... @@ -654,7 +654,7 @@ 654 654 655 655 (% class="box warningmessage" %) 656 656 ((( 657 -If there is the "WDT reset" error, the **“Critical error”**is generated and**all relays open.**653 +If there is the "WDT reset" error, **the “Critical error” is generated and all relays open.** 658 658 ))) 659 659 660 660 == 3.6.23 Insulation monitoring == ... ... @@ -728,10 +728,7 @@ 728 728 729 729 The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time. 730 730 731 -(% class="box infomessage" %) 732 -((( 733 733 The "General error" is //indicative //and can be linked to any discrete output of the board. 734 -))) 735 735 736 736 == 3.6.26 Low SOC signal == 737 737 ... ... @@ -756,10 +756,7 @@ 756 756 757 757 * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 758 758 759 -(% class="box infomessage" %) 760 -((( 761 761 The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board. 762 -))) 763 763 764 764 == 3.6.27 High charging current signal == 765 765 ... ... @@ -784,10 +784,7 @@ 784 784 785 785 * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 786 786 787 -(% class="box infomessage" %) 788 -((( 789 789 The "High charging current" signal is //indicative //and can be linked to any discrete output of the board. 790 -))) 791 791 792 792 == 3.6.28 Heater control == 793 793 ... ... @@ -817,7 +817,7 @@ 817 817 818 818 (% class="box infomessage" %) 819 819 ((( 820 -If there is the "Heater" signal, the **heater**relay closes and/or a signal is output to the corresponded digital output.807 +If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 821 821 ))) 822 822 823 823 == 3.6.29 Heater (AUX) control == ... ... @@ -848,7 +848,7 @@ 848 848 849 849 (% class="box infomessage" %) 850 850 ((( 851 -If there is the "Heater (AUX)" signal, the **auxiliary heater**relay closes and/or a signal is output to the corresponded digital output.838 +If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output. 852 852 ))) 853 853 854 854 == 3.6.30 Cooler control == ... ... @@ -879,7 +879,7 @@ 879 879 880 880 (% class="box infomessage" %) 881 881 ((( 882 -If there is the "Cooler" signal, the **cooler**relay closes and/or a signal is output to the corresponded digital output.869 +If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output. 883 883 ))) 884 884 885 885 == 3.6.31 Fault simulation ==