Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -31,7 +31,7 @@ 31 31 32 32 (% class="box infomessage" %) 33 33 ((( 34 -If there is the "Overcurrent" error, the **charging**and**discharging**relay open.34 +If there is the "Overcurrent" error, the charging and discharging relay open. 35 35 ))) 36 36 37 37 == 3.6.2 Undervoltage protection == ... ... @@ -63,7 +63,7 @@ 63 63 64 64 (% class="box infomessage" %) 65 65 ((( 66 -If there is the "Undervoltage" error, the **discharging**relay opens.66 +If there is the "Undervoltage" error, the discharging relay opens. 67 67 ))) 68 68 69 69 3.6.3 Overvoltage protection ... ... @@ -94,7 +94,7 @@ 94 94 95 95 (% class="box infomessage" %) 96 96 ((( 97 -If there is the "Overvoltage" error, the **charging**relay and**discharging**relay opens (if the “Switch off the discharging relay on error” flag is set).97 +If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set). 98 98 ))) 99 99 100 100 == 3.6.4 Low temperature protection == ... ... @@ -128,8 +128,8 @@ 128 128 129 129 (% class="box infomessage" %) 130 130 ((( 131 -If there is the "Low CH temperature" error, the **charging**relay opens.132 -If there is the "Low DCH temperature" error, the **discharging**relay opens.131 +If there is the "Low CH temperature" error, the charging relay opens. 132 +If there is the "Low DCH temperature" error, the discharging relay opens. 133 133 ))) 134 134 135 135 == 3.6.5 High temperature protection == ... ... @@ -163,8 +163,8 @@ 163 163 164 164 (% class="box infomessage" %) 165 165 ((( 166 -If there is the "High CH temperature" error, the **charging**relay opens.167 -If there is the "High DCH temperature" error, the **discharging**relay opens.166 +If there is the "High CH temperature" error, the charging relay opens. 167 +If there is the "High DCH temperature" error, the discharging relay opens. 168 168 ))) 169 169 170 170 == 3.6.6 Battery cover protection == ... ... @@ -192,7 +192,7 @@ 192 192 193 193 (% class="box warningmessage" %) 194 194 ((( 195 -If there is the "Battery cover error", the **“Critical error”**is generated and**all relays open.**195 +**If there is the "Battery cover error", the “Critical error” is generated and all relays open.** 196 196 ))) 197 197 198 198 == 3.6.7 High humidity protection == ... ... @@ -254,7 +254,7 @@ 254 254 255 255 (% class="box warningmessage" %) 256 256 ((( 257 -If there is the “Water” error, ****the**“Critical error”**is generated and**all relays open.**257 +**If there is the “Water” error, the “Critical error” is generated and all relays open.** 258 258 ))) 259 259 260 260 == 3.6.9 Current sensor error == ... ... @@ -288,7 +288,7 @@ 288 288 289 289 (% class="box warningmessage" %) 290 290 ((( 291 -If there is the “Current sensor error”, the **“Critical error”**is generated and**all relays open.**291 +**If there is the “Current sensor error”, the “Critical error” is generated and all relays open.** 292 292 ))) 293 293 294 294 == 3.6.10 Short circuit protection == ... ... @@ -322,7 +322,7 @@ 322 322 323 323 (% class="box infomessage" %) 324 324 ((( 325 -If there is the "Short circuit" error, the **charging**relay opens (the “Switch off the charging relay on error” flag is set) and the**discharging**relay opens (the “Switch off the discharging relay on error flag” is set).325 +If there is the "Short circuit" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 326 326 ))) 327 327 328 328 == 3.6.11 Contactor high temperature protection == ... ... @@ -356,7 +356,7 @@ 356 356 357 357 (% class="box infomessage" %) 358 358 ((( 359 -If there is the "Contactor high temperature" error, the **charging**relay opens (the “Switch off the charging relay on error” flag is set) and the**discharging**relay opens (the “Switch off the discharging relay on error flag” is set).359 +If there is the "Contactor high temperature" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 360 360 ))) 361 361 362 362 == 3.6.12 Unallowable charging protection == ... ... @@ -386,7 +386,7 @@ 386 386 387 387 (% class="box infomessage" %) 388 388 ((( 389 -If there is the "Unallowable charging" error, the **discharging**relay opens.389 +If there is the "Unallowable charging" error, the discharging relay opens. 390 390 ))) 391 391 392 392 == 3.6.13 Stuck contactor protection == ... ... @@ -410,11 +410,6 @@ 410 410 411 411 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 412 412 413 -(% class="box warningmessage" %) 414 -((( 415 -If there is the “Stuck contactor error”, the **“Critical error” **is generated and **all relays open.** 416 -))) 417 - 418 418 == 3.6.14 Contactor feedback check == 419 419 420 420 The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see section Input and output signals). ... ... @@ -434,7 +434,6 @@ 434 434 435 435 * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 436 436 437 - 438 438 == 3.6.15 Charging contactor cycles protection == 439 439 440 440 The BMS protects the charging contactor against frequent switching. ... ... @@ -465,7 +465,7 @@ 465 465 466 466 (% class="box infomessage" %) 467 467 ((( 468 -If there is the "CH contactor cycles error" error, the **charging**relay opens.462 +If there is the "CH contactor cycles error" error, the charging relay opens. 469 469 ))) 470 470 471 471 == 3.6.16 Discharging contactor cycles protection == ... ... @@ -498,7 +498,7 @@ 498 498 499 499 (% class="box infomessage" %) 500 500 ((( 501 -If there is the "DCH contactor cycles error" error, the **discharging**relay opens.495 +If there is the "DCH contactor cycles error" error, the discharging relay opens. 502 502 ))) 503 503 504 504 == 3.6.17 Temperature sensor error == ... ... @@ -520,7 +520,7 @@ 520 520 521 521 (% class="box warningmessage" %) 522 522 ((( 523 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”**is generated and**all relays open.**517 +**If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the “Critical error” is generated and all relays open.** 524 524 ))) 525 525 526 526 == 3.6.18 Logic high temperature protection == ... ... @@ -548,7 +548,7 @@ 548 548 549 549 (% class="box infomessage" %) 550 550 ((( 551 -Cell balancing is prohibited for overheated boards. 545 +**Cell balancing is prohibited for overheated boards.** 552 552 ))) 553 553 554 554 == 3.6.19 Logic offline protection == ... ... @@ -574,7 +574,7 @@ 574 574 575 575 (% class="box warningmessage" %) 576 576 ((( 577 -If there is the "Logic offline" error, the **“Critical error”**is generated and**all relays open.**571 +**If there is the "Logic offline" error, the “Critical error” is generated and all relays open.** 578 578 ))) 579 579 580 580 == 3.6.20 Cell count protection == ... ... @@ -603,7 +603,7 @@ 603 603 604 604 (% class="box warningmessage" %) 605 605 ((( 606 -If there is the "Cell count error", ****the**“Critical error”**is generated and**all relays open.**600 +**If there is the "Cell count error", the “Critical error” is generated and all relays open.** 607 607 ))) 608 608 609 609 == 3.6.21 Logic count protection == ... ... @@ -631,7 +631,7 @@ 631 631 632 632 (% class="box warningmessage" %) 633 633 ((( 634 -If there is the "Logic count error", the **“Critical error”**is generated and**all relays open.**628 +**If there is the "Logic count error", the “Critical error” is generated and all relays open.** 635 635 ))) 636 636 637 637 == 3.6.22 WDT protection == ... ... @@ -654,7 +654,7 @@ 654 654 655 655 (% class="box warningmessage" %) 656 656 ((( 657 -If there is the "WDT reset" error, the **“Critical error”**is generated and**all relays open.**651 +**If there is the "WDT reset" error, the “Critical error” is generated and all relays open.** 658 658 ))) 659 659 660 660 == 3.6.23 Insulation monitoring == ... ... @@ -728,10 +728,7 @@ 728 728 729 729 The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time. 730 730 731 -(% class="box infomessage" %) 732 -((( 733 733 The "General error" is //indicative //and can be linked to any discrete output of the board. 734 -))) 735 735 736 736 == 3.6.26 Low SOC signal == 737 737 ... ... @@ -756,10 +756,7 @@ 756 756 757 757 * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 758 758 759 -(% class="box infomessage" %) 760 -((( 761 761 The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board. 762 -))) 763 763 764 764 == 3.6.27 High charging current signal == 765 765 ... ... @@ -784,10 +784,7 @@ 784 784 785 785 * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 786 786 787 -(% class="box infomessage" %) 788 -((( 789 789 The "High charging current" signal is //indicative //and can be linked to any discrete output of the board. 790 -))) 791 791 792 792 == 3.6.28 Heater control == 793 793 ... ... @@ -817,7 +817,7 @@ 817 817 818 818 (% class="box infomessage" %) 819 819 ((( 820 -If there is the "Heater" signal, the **heater**relay closes and/or a signal is output to the corresponded digital output.805 +If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 821 821 ))) 822 822 823 823 == 3.6.29 Heater (AUX) control == ... ... @@ -848,7 +848,7 @@ 848 848 849 849 (% class="box infomessage" %) 850 850 ((( 851 -If there is the "Heater (AUX)" signal, the **auxiliary heater**relay closes and/or a signal is output to the corresponded digital output.836 +If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output. 852 852 ))) 853 853 854 854 == 3.6.30 Cooler control == ... ... @@ -855,7 +855,7 @@ 855 855 856 856 To change the parameters of the cooler control algorithm, select the menu "Protections → Cooler control": 857 857 858 -[[Cooler control settings>>image:1732215313977-499.png||data-xwiki-image-style-alignment="center" height=" 219" width="348"]]843 +[[Cooler control settings>>image:1732215313977-499.png||data-xwiki-image-style-alignment="center" height="198" width="315"]] 859 859 860 860 In this section: 861 861 ... ... @@ -879,7 +879,7 @@ 879 879 880 880 (% class="box infomessage" %) 881 881 ((( 882 -If there is the "Cooler" signal, the **cooler**relay closes and/or a signal is output to the corresponded digital output.867 +If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output. 883 883 ))) 884 884 885 885 == 3.6.31 Fault simulation == ... ... @@ -888,7 +888,6 @@ 888 888 889 889 To simulate battery and BMS errors, select the menu "Protections → Fault simulation": 890 890 891 -[[Fault simulation settings>>image:1732215359330-850.png||data-xwiki-image-style-alignment="center" height="732" width="204"]] 892 892 893 893 In this section: 894 894