Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -516,7 +516,7 @@ 516 516 517 517 (% class="box warningmessage" %) 518 518 ((( 519 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”**is generated and**all relays open.**519 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, **the “Critical error” is generated and all relays open.** 520 520 ))) 521 521 522 522 == 3.6.18 Logic high temperature protection == ... ... @@ -570,7 +570,7 @@ 570 570 571 571 (% class="box warningmessage" %) 572 572 ((( 573 -If there is the "Logic offline" error, the **“Critical error”**is generated and**all relays open.**573 +If there is the "Logic offline" error, **the “Critical error” is generated and all relays open.** 574 574 ))) 575 575 576 576 == 3.6.20 Cell count protection == ... ... @@ -599,7 +599,7 @@ 599 599 600 600 (% class="box warningmessage" %) 601 601 ((( 602 -If there is the "Cell count error",** **the**“Critical error”**is generated and**all relays open.**602 +If there is the "Cell count error",** the “Critical error” is generated and all relays open.** 603 603 ))) 604 604 605 605 == 3.6.21 Logic count protection == ... ... @@ -627,7 +627,7 @@ 627 627 628 628 (% class="box warningmessage" %) 629 629 ((( 630 -If there is the "Logic count error", the **“Critical error”**is generated and**all relays open.**630 +If there is the "Logic count error", **the “Critical error” is generated and all relays open.** 631 631 ))) 632 632 633 633 == 3.6.22 WDT protection == ... ... @@ -650,7 +650,7 @@ 650 650 651 651 (% class="box warningmessage" %) 652 652 ((( 653 -If there is the "WDT reset" error, the **“Critical error”**is generated and**all relays open.**653 +If there is the "WDT reset" error, **the “Critical error” is generated and all relays open.** 654 654 ))) 655 655 656 656 == 3.6.23 Insulation monitoring == ... ... @@ -724,10 +724,7 @@ 724 724 725 725 The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time. 726 726 727 -(% class="box infomessage" %) 728 -((( 729 729 The "General error" is //indicative //and can be linked to any discrete output of the board. 730 -))) 731 731 732 732 == 3.6.26 Low SOC signal == 733 733 ... ... @@ -752,10 +752,7 @@ 752 752 753 753 * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 754 754 755 -(% class="box infomessage" %) 756 -((( 757 757 The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board. 758 -))) 759 759 760 760 == 3.6.27 High charging current signal == 761 761 ... ... @@ -780,10 +780,7 @@ 780 780 781 781 * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 782 782 783 -(% class="box infomessage" %) 784 -((( 785 785 The "High charging current" signal is //indicative //and can be linked to any discrete output of the board. 786 -))) 787 787 788 788 == 3.6.28 Heater control == 789 789 ... ... @@ -813,7 +813,7 @@ 813 813 814 814 (% class="box infomessage" %) 815 815 ((( 816 -If there is the "Heater" signal, the **heater**relay closes and/or a signal is output to the corresponded digital output.807 +If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 817 817 ))) 818 818 819 819 == 3.6.29 Heater (AUX) control == ... ... @@ -844,7 +844,7 @@ 844 844 845 845 (% class="box infomessage" %) 846 846 ((( 847 -If there is the "Heater (AUX)" signal, the **auxiliary heater**relay closes and/or a signal is output to the corresponded digital output.838 +If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output. 848 848 ))) 849 849 850 850 == 3.6.30 Cooler control ==