Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -356,7 +356,7 @@ 356 356 357 357 (% class="box infomessage" %) 358 358 ((( 359 -If there is the "Contactor high temperature" error, the **charging**relay opens (the “Switch off the charging relay on error” flag is set) and the**discharging**relay opens (the “Switch off the discharging relay on error flag” is set).359 +If there is the "Contactor high temperature" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 360 360 ))) 361 361 362 362 == 3.6.12 Unallowable charging protection == ... ... @@ -386,7 +386,7 @@ 386 386 387 387 (% class="box infomessage" %) 388 388 ((( 389 -If there is the "Unallowable charging" error, the **discharging**relay opens.389 +If there is the "Unallowable charging" error, the discharging relay opens. 390 390 ))) 391 391 392 392 == 3.6.13 Stuck contactor protection == ... ... @@ -410,7 +410,6 @@ 410 410 411 411 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 412 412 413 - 414 414 == 3.6.14 Contactor feedback check == 415 415 416 416 The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see section Input and output signals). ... ... @@ -430,7 +430,6 @@ 430 430 431 431 * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 432 432 433 - 434 434 == 3.6.15 Charging contactor cycles protection == 435 435 436 436 The BMS protects the charging contactor against frequent switching. ... ... @@ -461,7 +461,7 @@ 461 461 462 462 (% class="box infomessage" %) 463 463 ((( 464 -If there is the "CH contactor cycles error" error, the **charging**relay opens.462 +If there is the "CH contactor cycles error" error, the charging relay opens. 465 465 ))) 466 466 467 467 == 3.6.16 Discharging contactor cycles protection == ... ... @@ -494,7 +494,7 @@ 494 494 495 495 (% class="box infomessage" %) 496 496 ((( 497 -If there is the "DCH contactor cycles error" error, the **discharging**relay opens.495 +If there is the "DCH contactor cycles error" error, the discharging relay opens. 498 498 ))) 499 499 500 500 == 3.6.17 Temperature sensor error == ... ... @@ -516,7 +516,7 @@ 516 516 517 517 (% class="box warningmessage" %) 518 518 ((( 519 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”**is generated and**all relays open.**517 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, **the “Critical error” is generated and all relays open.** 520 520 ))) 521 521 522 522 == 3.6.18 Logic high temperature protection == ... ... @@ -570,7 +570,7 @@ 570 570 571 571 (% class="box warningmessage" %) 572 572 ((( 573 -If there is the "Logic offline" error, the **“Critical error”**is generated and**all relays open.**571 +If there is the "Logic offline" error, **the “Critical error” is generated and all relays open.** 574 574 ))) 575 575 576 576 == 3.6.20 Cell count protection == ... ... @@ -599,7 +599,7 @@ 599 599 600 600 (% class="box warningmessage" %) 601 601 ((( 602 -If there is the "Cell count error",** **the**“Critical error”**is generated and**all relays open.**600 +If there is the "Cell count error",** the “Critical error” is generated and all relays open.** 603 603 ))) 604 604 605 605 == 3.6.21 Logic count protection == ... ... @@ -627,7 +627,7 @@ 627 627 628 628 (% class="box warningmessage" %) 629 629 ((( 630 -If there is the "Logic count error", the **“Critical error”**is generated and**all relays open.**628 +If there is the "Logic count error", **the “Critical error” is generated and all relays open.** 631 631 ))) 632 632 633 633 == 3.6.22 WDT protection == ... ... @@ -650,7 +650,7 @@ 650 650 651 651 (% class="box warningmessage" %) 652 652 ((( 653 -If there is the "WDT reset" error, the **“Critical error”**is generated and**all relays open.**651 +If there is the "WDT reset" error, **the “Critical error” is generated and all relays open.** 654 654 ))) 655 655 656 656 == 3.6.23 Insulation monitoring == ... ... @@ -724,10 +724,7 @@ 724 724 725 725 The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time. 726 726 727 -(% class="box infomessage" %) 728 -((( 729 729 The "General error" is //indicative //and can be linked to any discrete output of the board. 730 -))) 731 731 732 732 == 3.6.26 Low SOC signal == 733 733 ... ... @@ -752,10 +752,7 @@ 752 752 753 753 * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 754 754 755 -(% class="box infomessage" %) 756 -((( 757 757 The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board. 758 -))) 759 759 760 760 == 3.6.27 High charging current signal == 761 761 ... ... @@ -780,10 +780,7 @@ 780 780 781 781 * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 782 782 783 -(% class="box infomessage" %) 784 -((( 785 785 The "High charging current" signal is //indicative //and can be linked to any discrete output of the board. 786 -))) 787 787 788 788 == 3.6.28 Heater control == 789 789 ... ... @@ -813,7 +813,7 @@ 813 813 814 814 (% class="box infomessage" %) 815 815 ((( 816 -If there is the "Heater" signal, the **heater**relay closes and/or a signal is output to the corresponded digital output.805 +If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 817 817 ))) 818 818 819 819 == 3.6.29 Heater (AUX) control == ... ... @@ -844,7 +844,7 @@ 844 844 845 845 (% class="box infomessage" %) 846 846 ((( 847 -If there is the "Heater (AUX)" signal, the **auxiliary heater**relay closes and/or a signal is output to the corresponded digital output.836 +If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output. 848 848 ))) 849 849 850 850 == 3.6.30 Cooler control ==