Changes for page 3.6 Battery protection

Last modified by Admin on 2025/04/09 12:25

From version 33.6
edited by Admin
on 2024/11/21 19:01
Change comment: There is no comment for this version
To version 33.11
edited by Admin
on 2024/11/21 19:16
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -410,6 +410,10 @@
410 410  
411 411  * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set.
412 412  
413 +(% class="box warningmessage" %)
414 +(((
415 +If there is the “Stuck contactor error”, the **“Critical error” **is generated and **all relays open.**
416 +)))
413 413  
414 414  == 3.6.14 Contactor feedback check ==
415 415  
... ... @@ -430,6 +430,10 @@
430 430  
431 431  * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value.
432 432  
437 +(% class="box warningmessage" %)
438 +(((
439 +If there is the contactor feedback error, the **“Critical error” **is generated and **all relays open.**
440 +)))
433 433  
434 434  == 3.6.15 Charging contactor cycles protection ==
435 435  
... ... @@ -670,6 +670,11 @@
670 670  
671 671  Error is set if corresponding discrete input is set up and it received logical zero.
672 672  
681 +(% class="box warningmessage" %)
682 +(((
683 +If there is the "Insulation monitoring" error, the **“Critical error”** is generated and** all relays open.**
684 +)))
685 +
673 673  == 3.6.24 Critical error parameters ==
674 674  
675 675  To change the critical error parameters, select the menu "Protections → Critical error parameters":
... ... @@ -694,10 +694,12 @@
694 694  * “No temp. sensors”;
695 695  * “Temp. sensor is shorted”;
696 696  * “Current sensor error”;
710 +* "
697 697  * “Shunt offline”;
698 698  * “Shunt error”;
699 699  * “Settings error”;
700 -* “WDT reset”.
714 +* “WDT reset”
715 +* "Insulation monitoring".
701 701  
702 702  The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
703 703  
... ... @@ -875,7 +875,7 @@
875 875  
876 876  (% class="box infomessage" %)
877 877  (((
878 -If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output.
893 +If there is the "Cooler" signal, the **cooler **relay closes and/or a signal is output to the corresponded digital output.
879 879  )))
880 880  
881 881  == 3.6.31 Fault simulation ==