Changes for page 3.6 Battery protection

Last modified by Admin on 2025/04/09 12:25

From version 33.5
edited by Admin
on 2024/11/21 19:00
Change comment: There is no comment for this version
To version 33.9
edited by Admin
on 2024/11/21 19:16
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -410,6 +410,10 @@
410 410  
411 411  * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set.
412 412  
413 +(% class="box warningmessage" %)
414 +(((
415 +If there is the “Stuck contactor error”, the **“Critical error” **is generated and **all relays open.**
416 +)))
413 413  
414 414  == 3.6.14 Contactor feedback check ==
415 415  
... ... @@ -430,6 +430,10 @@
430 430  
431 431  * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value.
432 432  
437 +(% class="box warningmessage" %)
438 +(((
439 +If there is the contactor feedback error, the **“Critical error” **is generated and **all relays open.**
440 +)))
433 433  
434 434  == 3.6.15 Charging contactor cycles protection ==
435 435  
... ... @@ -516,7 +516,7 @@
516 516  
517 517  (% class="box warningmessage" %)
518 518  (((
519 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, **the “Critical error” is generated and all relays open.**
527 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error” **is generated and **all relays open.**
520 520  )))
521 521  
522 522  == 3.6.18 Logic high temperature protection ==
... ... @@ -570,7 +570,7 @@
570 570  
571 571  (% class="box warningmessage" %)
572 572  (((
573 -If there is the "Logic offline" error, **the “Critical error” is generated and all relays open.**
581 +If there is the "Logic offline" error, the **“Critical error”** is generated and **all relays open.**
574 574  )))
575 575  
576 576  == 3.6.20 Cell count protection ==
... ... @@ -599,7 +599,7 @@
599 599  
600 600  (% class="box warningmessage" %)
601 601  (((
602 -If there is the "Cell count error",** the “Critical error” is generated and all relays open.**
610 +If there is the "Cell count error",** **the **“Critical error”** is generated and **all relays open.**
603 603  )))
604 604  
605 605  == 3.6.21 Logic count protection ==
... ... @@ -627,7 +627,7 @@
627 627  
628 628  (% class="box warningmessage" %)
629 629  (((
630 -If there is the "Logic count error", **the “Critical error” is generated and all relays open.**
638 +If there is the "Logic count error", the **“Critical error” **is generated and **all relays open.**
631 631  )))
632 632  
633 633  == 3.6.22 WDT protection ==
... ... @@ -650,7 +650,7 @@
650 650  
651 651  (% class="box warningmessage" %)
652 652  (((
653 -If there is the "WDT reset" error, **the “Critical error” is generated and all relays open.**
661 +If there is the "WDT reset" error, the **“Critical error”** is generated and** all relays open.**
654 654  )))
655 655  
656 656  == 3.6.23 Insulation monitoring ==
... ... @@ -670,6 +670,11 @@
670 670  
671 671  Error is set if corresponding discrete input is set up and it received logical zero.
672 672  
681 +(% class="box warningmessage" %)
682 +(((
683 +If there is the "Insulation monitoring" error, the **“Critical error”** is generated and** all relays open.**
684 +)))
685 +
673 673  == 3.6.24 Critical error parameters ==
674 674  
675 675  To change the critical error parameters, select the menu "Protections → Critical error parameters":
... ... @@ -694,10 +694,12 @@
694 694  * “No temp. sensors”;
695 695  * “Temp. sensor is shorted”;
696 696  * “Current sensor error”;
710 +* S
697 697  * “Shunt offline”;
698 698  * “Shunt error”;
699 699  * “Settings error”;
700 -* “WDT reset”.
714 +* “WDT reset”
715 +* "Insulation monitoring".
701 701  
702 702  The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
703 703  
... ... @@ -724,7 +724,10 @@
724 724  
725 725  The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time.
726 726  
742 +(% class="box infomessage" %)
743 +(((
727 727  The "General error" is //indicative //and can be linked to any discrete output of the board.
745 +)))
728 728  
729 729  == 3.6.26 Low SOC signal ==
730 730  
... ... @@ -749,7 +749,10 @@
749 749  
750 750  * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time.
751 751  
770 +(% class="box infomessage" %)
771 +(((
752 752  The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board.
773 +)))
753 753  
754 754  == 3.6.27 High charging current signal ==
755 755  
... ... @@ -774,7 +774,10 @@
774 774  
775 775  * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time.
776 776  
798 +(% class="box infomessage" %)
799 +(((
777 777  The "High charging current" signal is //indicative //and can be linked to any discrete output of the board.
801 +)))
778 778  
779 779  == 3.6.28 Heater control ==
780 780  
... ... @@ -804,7 +804,7 @@
804 804  
805 805  (% class="box infomessage" %)
806 806  (((
807 -If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output.
831 +If there is the "Heater" signal, the **heater **relay closes and/or a signal is output to the corresponded digital output.
808 808  )))
809 809  
810 810  == 3.6.29 Heater (AUX) control ==
... ... @@ -835,7 +835,7 @@
835 835  
836 836  (% class="box infomessage" %)
837 837  (((
838 -If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output.
862 +If there is the "Heater (AUX)" signal, the **auxiliary heater **relay closes and/or a signal is output to the corresponded digital output.
839 839  )))
840 840  
841 841  == 3.6.30 Cooler control ==
... ... @@ -866,7 +866,7 @@
866 866  
867 867  (% class="box infomessage" %)
868 868  (((
869 -If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output.
893 +If there is the "Cooler" signal, the **cooler **relay closes and/or a signal is output to the corresponded digital output.
870 870  )))
871 871  
872 872  == 3.6.31 Fault simulation ==