Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -516,7 +516,7 @@ 516 516 517 517 (% class="box warningmessage" %) 518 518 ((( 519 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, **the “Critical error” is generated and all relays open.**519 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error” **is generated and **all relays open.** 520 520 ))) 521 521 522 522 == 3.6.18 Logic high temperature protection == ... ... @@ -570,7 +570,7 @@ 570 570 571 571 (% class="box warningmessage" %) 572 572 ((( 573 -If there is the "Logic offline" error, **the “Critical error” is generated and all relays open.**573 +If there is the "Logic offline" error, the **“Critical error”** is generated and **all relays open.** 574 574 ))) 575 575 576 576 == 3.6.20 Cell count protection == ... ... @@ -599,7 +599,7 @@ 599 599 600 600 (% class="box warningmessage" %) 601 601 ((( 602 -If there is the "Cell count error",** the “Critical error” is generated and all relays open.** 602 +If there is the "Cell count error",** **the **“Critical error”** is generated and **all relays open.** 603 603 ))) 604 604 605 605 == 3.6.21 Logic count protection == ... ... @@ -627,7 +627,7 @@ 627 627 628 628 (% class="box warningmessage" %) 629 629 ((( 630 -If there is the "Logic count error", **the “Critical error” is generated and all relays open.**630 +If there is the "Logic count error", the **“Critical error” **is generated and **all relays open.** 631 631 ))) 632 632 633 633 == 3.6.22 WDT protection == ... ... @@ -650,7 +650,7 @@ 650 650 651 651 (% class="box warningmessage" %) 652 652 ((( 653 -If there is the "WDT reset" error, **the “Critical error” is generated and all relays open.**653 +If there is the "WDT reset" error, the **“Critical error”** is generated and** all relays open.** 654 654 ))) 655 655 656 656 == 3.6.23 Insulation monitoring == ... ... @@ -724,7 +724,10 @@ 724 724 725 725 The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time. 726 726 727 +(% class="box infomessage" %) 728 +((( 727 727 The "General error" is //indicative //and can be linked to any discrete output of the board. 730 +))) 728 728 729 729 == 3.6.26 Low SOC signal == 730 730 ... ... @@ -749,7 +749,10 @@ 749 749 750 750 * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 751 751 755 +(% class="box infomessage" %) 756 +((( 752 752 The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board. 758 +))) 753 753 754 754 == 3.6.27 High charging current signal == 755 755 ... ... @@ -774,7 +774,10 @@ 774 774 775 775 * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 776 776 783 +(% class="box infomessage" %) 784 +((( 777 777 The "High charging current" signal is //indicative //and can be linked to any discrete output of the board. 786 +))) 778 778 779 779 == 3.6.28 Heater control == 780 780 ... ... @@ -804,7 +804,7 @@ 804 804 805 805 (% class="box infomessage" %) 806 806 ((( 807 -If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 816 +If there is the "Heater" signal, the **heater **relay closes and/or a signal is output to the corresponded digital output. 808 808 ))) 809 809 810 810 == 3.6.29 Heater (AUX) control == ... ... @@ -835,7 +835,7 @@ 835 835 836 836 (% class="box infomessage" %) 837 837 ((( 838 -If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output. 847 +If there is the "Heater (AUX)" signal, the **auxiliary heater **relay closes and/or a signal is output to the corresponded digital output. 839 839 ))) 840 840 841 841 == 3.6.30 Cooler control ==