... ... @@ -356,7 +356,7 @@
356 356  
357 357  (% class="box infomessage" %)
358 358  (((
359 -If there is the "Contactor high temperature" error, the **charging **relay opens (the “Switch off the charging relay on error” flag is set) and the **discharging **relay opens (the “Switch off the discharging relay on error flag” is set).
359 +If there is the "Contactor high temperature" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set).
360 360  )))
361 361  
362 362  == 3.6.12 Unallowable charging protection ==
... ... @@ -386,7 +386,7 @@
386 386  
387 387  (% class="box infomessage" %)
388 388  (((
389 -If there is the "Unallowable charging" error, the **discharging **relay opens.
389 +If there is the "Unallowable charging" error, the discharging relay opens.
390 390  )))
391 391  
392 392  == 3.6.13 Stuck contactor protection ==
... ... @@ -410,7 +410,6 @@
410 410  
411 411  * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set.
412 412  
413 -
414 414  == 3.6.14 Contactor feedback check ==
415 415  
416 416  The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see section Input and output signals).
... ... @@ -430,7 +430,6 @@
430 430  
431 431  * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value.
432 432  
433 -
434 434  == 3.6.15 Charging contactor cycles protection ==
435 435  
436 436  The BMS protects the charging contactor against frequent switching.
... ... @@ -461,7 +461,7 @@
461 461  
462 462  (% class="box infomessage" %)
463 463  (((
464 -If there is the "CH contactor cycles error" error, the **charging **relay opens.
462 +If there is the "CH contactor cycles error" error, the charging relay opens.
465 465  )))
466 466  
467 467  == 3.6.16 Discharging contactor cycles protection ==
... ... @@ -494,7 +494,7 @@
494 494  
495 495  (% class="box infomessage" %)
496 496  (((
497 -If there is the "DCH contactor cycles error" error, the **discharging **relay opens.
495 +If there is the "DCH contactor cycles error" error, the discharging relay opens.
498 498  )))
499 499  
500 500  == 3.6.17 Temperature sensor error ==