Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -356,7 +356,7 @@ 356 356 357 357 (% class="box infomessage" %) 358 358 ((( 359 -If there is the "Contactor high temperature" error, the **charging**relay opens (the “Switch off the charging relay on error” flag is set) and the**discharging**relay opens (the “Switch off the discharging relay on error flag” is set).359 +If there is the "Contactor high temperature" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 360 360 ))) 361 361 362 362 == 3.6.12 Unallowable charging protection == ... ... @@ -386,7 +386,7 @@ 386 386 387 387 (% class="box infomessage" %) 388 388 ((( 389 -If there is the "Unallowable charging" error, the **discharging**relay opens.389 +If there is the "Unallowable charging" error, the discharging relay opens. 390 390 ))) 391 391 392 392 == 3.6.13 Stuck contactor protection == ... ... @@ -410,7 +410,6 @@ 410 410 411 411 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 412 412 413 - 414 414 == 3.6.14 Contactor feedback check == 415 415 416 416 The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see section Input and output signals). ... ... @@ -430,7 +430,6 @@ 430 430 431 431 * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 432 432 433 - 434 434 == 3.6.15 Charging contactor cycles protection == 435 435 436 436 The BMS protects the charging contactor against frequent switching. ... ... @@ -461,7 +461,7 @@ 461 461 462 462 (% class="box infomessage" %) 463 463 ((( 464 -If there is the "CH contactor cycles error" error, the **charging**relay opens.462 +If there is the "CH contactor cycles error" error, the charging relay opens. 465 465 ))) 466 466 467 467 == 3.6.16 Discharging contactor cycles protection == ... ... @@ -494,7 +494,7 @@ 494 494 495 495 (% class="box infomessage" %) 496 496 ((( 497 -If there is the "DCH contactor cycles error" error, the **discharging**relay opens.495 +If there is the "DCH contactor cycles error" error, the discharging relay opens. 498 498 ))) 499 499 500 500 == 3.6.17 Temperature sensor error ==