Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -31,7 +31,7 @@ 31 31 32 32 (% class="box infomessage" %) 33 33 ((( 34 -If there is the "Overcurrent" error, the **charging**and**discharging**relay open.34 +If there is the "Overcurrent" error, the charging and discharging relay open. 35 35 ))) 36 36 37 37 == 3.6.2 Undervoltage protection == ... ... @@ -63,7 +63,7 @@ 63 63 64 64 (% class="box infomessage" %) 65 65 ((( 66 -If there is the "Undervoltage" error, the **discharging**relay opens.66 +If there is the "Undervoltage" error, the discharging relay opens. 67 67 ))) 68 68 69 69 3.6.3 Overvoltage protection ... ... @@ -94,7 +94,7 @@ 94 94 95 95 (% class="box infomessage" %) 96 96 ((( 97 -If there is the "Overvoltage" error, the **charging**relay and**discharging**relay opens (if the “Switch off the discharging relay on error” flag is set).97 +If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set). 98 98 ))) 99 99 100 100 == 3.6.4 Low temperature protection == ... ... @@ -128,8 +128,8 @@ 128 128 129 129 (% class="box infomessage" %) 130 130 ((( 131 -If there is the "Low CH temperature" error, the **charging**relay opens.132 -If there is the "Low DCH temperature" error, the **discharging**relay opens.131 +If there is the "Low CH temperature" error, the charging relay opens. 132 +If there is the "Low DCH temperature" error, the discharging relay opens. 133 133 ))) 134 134 135 135 == 3.6.5 High temperature protection == ... ... @@ -163,8 +163,8 @@ 163 163 164 164 (% class="box infomessage" %) 165 165 ((( 166 -If there is the "High CH temperature" error, the **charging**relay opens.167 -If there is the "High DCH temperature" error, the **discharging**relay opens.166 +If there is the "High CH temperature" error, the charging relay opens. 167 +If there is the "High DCH temperature" error, the discharging relay opens. 168 168 ))) 169 169 170 170 == 3.6.6 Battery cover protection == ... ... @@ -192,7 +192,7 @@ 192 192 193 193 (% class="box warningmessage" %) 194 194 ((( 195 -If there is the "Battery cover error", the **“Critical error”**is generated and**all relays open.**195 +If there is the "Battery cover error", **the “Critical error” is generated and all relays open.** 196 196 ))) 197 197 198 198 == 3.6.7 High humidity protection == ... ... @@ -254,7 +254,7 @@ 254 254 255 255 (% class="box warningmessage" %) 256 256 ((( 257 -If there is the “Water” error, ****the**“Critical error”**is generated and**all relays open.**257 +**If there is the “Water” error, the “Critical error” is generated and all relays open.** 258 258 ))) 259 259 260 260 == 3.6.9 Current sensor error == ... ... @@ -288,7 +288,7 @@ 288 288 289 289 (% class="box warningmessage" %) 290 290 ((( 291 -If there is the “Current sensor error”, the **“Critical error”**is generated and**all relays open.**291 +**If there is the “Current sensor error”, the “Critical error” is generated and all relays open.** 292 292 ))) 293 293 294 294 == 3.6.10 Short circuit protection == ... ... @@ -322,7 +322,7 @@ 322 322 323 323 (% class="box infomessage" %) 324 324 ((( 325 -If there is the "Short circuit" error, the **charging**relay opens (the “Switch off the charging relay on error” flag is set) and the**discharging**relay opens (the “Switch off the discharging relay on error flag” is set).325 +If there is the "Short circuit" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 326 326 ))) 327 327 328 328 == 3.6.11 Contactor high temperature protection == ... ... @@ -356,7 +356,7 @@ 356 356 357 357 (% class="box infomessage" %) 358 358 ((( 359 -If there is the "Contactor high temperature" error, the **charging**relay opens (the “Switch off the charging relay on error” flag is set) and the**discharging**relay opens (the “Switch off the discharging relay on error flag” is set).359 +If there is the "Contactor high temperature" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 360 360 ))) 361 361 362 362 == 3.6.12 Unallowable charging protection == ... ... @@ -386,7 +386,7 @@ 386 386 387 387 (% class="box infomessage" %) 388 388 ((( 389 -If there is the "Unallowable charging" error, the **discharging**relay opens.389 +If there is the "Unallowable charging" error, the discharging relay opens. 390 390 ))) 391 391 392 392 == 3.6.13 Stuck contactor protection == ... ... @@ -410,7 +410,6 @@ 410 410 411 411 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 412 412 413 - 414 414 == 3.6.14 Contactor feedback check == 415 415 416 416 The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see section Input and output signals). ... ... @@ -430,7 +430,6 @@ 430 430 431 431 * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 432 432 433 - 434 434 == 3.6.15 Charging contactor cycles protection == 435 435 436 436 The BMS protects the charging contactor against frequent switching. ... ... @@ -461,7 +461,7 @@ 461 461 462 462 (% class="box infomessage" %) 463 463 ((( 464 -If there is the "CH contactor cycles error" error, the **charging**relay opens.462 +If there is the "CH contactor cycles error" error, the charging relay opens. 465 465 ))) 466 466 467 467 == 3.6.16 Discharging contactor cycles protection == ... ... @@ -494,7 +494,7 @@ 494 494 495 495 (% class="box infomessage" %) 496 496 ((( 497 -If there is the "DCH contactor cycles error" error, the **discharging**relay opens.495 +If there is the "DCH contactor cycles error" error, the discharging relay opens. 498 498 ))) 499 499 500 500 == 3.6.17 Temperature sensor error == ... ... @@ -516,7 +516,7 @@ 516 516 517 517 (% class="box warningmessage" %) 518 518 ((( 519 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, **the “Critical error” is generated and all relays open.**517 +**If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the “Critical error” is generated and all relays open.** 520 520 ))) 521 521 522 522 == 3.6.18 Logic high temperature protection == ... ... @@ -544,7 +544,7 @@ 544 544 545 545 (% class="box infomessage" %) 546 546 ((( 547 -Cell balancing is prohibited for overheated boards. 545 +**Cell balancing is prohibited for overheated boards.** 548 548 ))) 549 549 550 550 == 3.6.19 Logic offline protection == ... ... @@ -570,7 +570,7 @@ 570 570 571 571 (% class="box warningmessage" %) 572 572 ((( 573 -If there is the "Logic offline" error, **the “Critical error” is generated and all relays open.**571 +**If there is the "Logic offline" error, the “Critical error” is generated and all relays open.** 574 574 ))) 575 575 576 576 == 3.6.20 Cell count protection == ... ... @@ -599,7 +599,7 @@ 599 599 600 600 (% class="box warningmessage" %) 601 601 ((( 602 -If there is the "Cell count error", **the “Critical error” is generated and all relays open.**600 +**If there is the "Cell count error", the “Critical error” is generated and all relays open.** 603 603 ))) 604 604 605 605 == 3.6.21 Logic count protection == ... ... @@ -627,7 +627,7 @@ 627 627 628 628 (% class="box warningmessage" %) 629 629 ((( 630 -If there is the "Logic count error", **the “Critical error” is generated and all relays open.**628 +**If there is the "Logic count error", the “Critical error” is generated and all relays open.** 631 631 ))) 632 632 633 633 == 3.6.22 WDT protection == ... ... @@ -650,7 +650,7 @@ 650 650 651 651 (% class="box warningmessage" %) 652 652 ((( 653 -If there is the "WDT reset" error, **the “Critical error” is generated and all relays open.**651 +**If there is the "WDT reset" error, the “Critical error” is generated and all relays open.** 654 654 ))) 655 655 656 656 == 3.6.23 Insulation monitoring ==