Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -drafts. bms-main-2-1.configuration.WebHome1 +drafts.BMS Main 2\.1.3\. Configuration.WebHome - Content
-
... ... @@ -1,10 +1,16 @@ 1 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += Configuration = 3 + 4 +(% data-numbered-headings-start="6" style="--numbered-headings-start: 5;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 +== Battery protection == 6 + 1 1 The BMS Main 2.x board continuously monitors the state of the cells, BMS Logic boards, the external environment and, when detecting abnormalities, protects the battery and system components from damage. 2 2 3 -== 3.6.1Overcurrent protection ==9 +=== Overcurrent protection === 4 4 5 5 To change the current protection of the battery, select the menu "Protections → Overcurrent protection": 6 6 7 -[[ Overcurrent protection settings>>image:1732211959984-118.png||data-xwiki-image-style-alignment="center" height="266" width="386"]]13 +[[image:1732211959984-118.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="266" width="386"]] 8 8 9 9 In this section: 10 10 ... ... @@ -34,13 +34,13 @@ 34 34 If there is the "Overcurrent" error, the **charging **and **discharging **relay open. 35 35 ))) 36 36 37 -== 3.6.2Undervoltage protection ==43 +=== Undervoltage protection === 38 38 39 39 The board implements battery protection from too low or too high voltage on the cells. 40 40 41 41 To change the battery protection parameters from low voltage on the cells, select the menu "Protections → Undervoltage protection": 42 42 43 -[[ Undervoltage protection settings>>image:1732212212350-294.png||data-xwiki-image-style-alignment="center" height="207" width="359"]]49 +[[image:1732212212350-294.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="359"]] 44 44 45 45 In this section: 46 46 ... ... @@ -66,11 +66,11 @@ 66 66 If there is the "Undervoltage" error, the **discharging **relay opens. 67 67 ))) 68 68 69 - 3.6.3Overvoltage protection75 +=== Overvoltage protection === 70 70 71 71 To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection": 72 72 73 -[[ Overvoltage protection settings>>image:1732212357972-295.png||data-xwiki-image-style-alignment="center" height="218" width="338"]]79 +[[image:1732212357972-295.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="218" width="338"]] 74 74 75 75 In this section: 76 76 ... ... @@ -97,13 +97,13 @@ 97 97 If there is the "Overvoltage" error, the **charging **relay and **discharging **relay opens (if the “Switch off the discharging relay on error” flag is set). 98 98 ))) 99 99 100 -== 3.6.4Low temperature protection ==106 +=== Low temperature protection === 101 101 102 102 The board implements battery protection from too low temperature. 103 103 104 104 To change the battery protection parameters from low temperature, select the menu "Protections → Low temperature protection": 105 105 106 -[[ Low temperature protection settings>>image:1732213953083-955.png||data-xwiki-image-style-alignment="center" height="237" width="338"]]112 +[[image:1732213953083-955.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="338"]] 107 107 108 108 In this section: 109 109 ... ... @@ -132,13 +132,13 @@ 132 132 If there is the "Low DCH temperature" error, the **discharging **relay opens. 133 133 ))) 134 134 135 -== 3.6.5High temperature protection ==141 +=== High temperature protection === 136 136 137 137 The board implements battery protection from too high temperature. 138 138 139 139 To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection": 140 140 141 -[[ High temperature protection settings>>image:1732213990755-759.png||data-xwiki-image-style-alignment="center" height="258" width="370"]]147 +[[image:1732213990755-759.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="258" width="370"]] 142 142 143 143 In this section: 144 144 ... ... @@ -167,11 +167,11 @@ 167 167 If there is the "High DCH temperature" error, the **discharging **relay opens. 168 168 ))) 169 169 170 -== 3.6.6Battery cover protection ==176 +=== Battery cover protection === 171 171 172 172 To change the protection parameters from opening the battery cover, select the menu "Protections → Battery cover protection": 173 173 174 -[[ Battery cover protection settings>>image:1732214030014-281.png||data-xwiki-image-style-alignment="center" height="155" width="334"]]180 +[[image:1732214030014-281.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="155" width="334"]] 175 175 176 176 In this section: 177 177 ... ... @@ -195,13 +195,13 @@ 195 195 If there is the "Battery cover error", the **“Critical error” **is generated and **all relays open.** 196 196 ))) 197 197 198 -== 3.6.7High humidity protection ==204 +=== High humidity protection === 199 199 200 200 The board can protect the battery from high humidity and water. 201 201 202 202 To change the protection parameters of the battery from high humidity, select the menu "Protections → High humidity protection": 203 203 204 -[[ High humidity protection settings>>image:1732214076060-358.png||data-xwiki-image-style-alignment="center" height="185" width="321"]]210 +[[image:1732214076060-358.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="185" width="321"]] 205 205 206 206 In this section: 207 207 ... ... @@ -227,11 +227,11 @@ 227 227 If there is the "High humidity" error, no action is taken. The error is indicative. 228 228 ))) 229 229 230 -== 3.6.8Water protection ==236 +=== Water protection === 231 231 232 232 To change the protection parameters of the battery from water, select the menu "Protections → Water protection": 233 233 234 -[[ Water protection settings>>image:1732214111990-184.png||data-xwiki-image-style-alignment="center" height="199" width="340"]]240 +[[image:1732214111990-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="199" width="340"]] 235 235 236 236 In this section: 237 237 ... ... @@ -257,13 +257,13 @@ 257 257 If there is the “Water” error,** **the **“Critical error”** is generated and **all relays open.** 258 258 ))) 259 259 260 -== 3.6.9Current sensor error ==266 +=== Current sensor error === 261 261 262 262 The board is implemented to check the current sensor connection circuits. The circuits are checked for breakage and short-circuit to the +5 V supply line. 263 263 264 264 To change the test parameters of the current sensor connection circuits, select the menu "Protections → Current sensor error": 265 265 266 -[[ Current sensor error settings>>image:1732214146724-132.png||data-xwiki-image-style-alignment="center" height="438" width="365"]]272 +[[image:1732214146724-132.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="438" width="365"]] 267 267 268 268 In this section: 269 269 ... ... @@ -291,13 +291,13 @@ 291 291 If there is the “Current sensor error”, the **“Critical error” **is generated and **all relays open.** 292 292 ))) 293 293 294 -== 3.6.10Short circuit protection ==300 +=== Short circuit protection === 295 295 296 296 The BMS implements a protection of power circuits (contactors, power cables) against overheating caused by the flow of high current for a long time. 297 297 298 298 To change the protection parameters from short circuit, select the menu "Protections → Short circuit protection": 299 299 300 -[[ Short circuit protection settings>>image:1732214207026-822.png||data-xwiki-image-style-alignment="center" height="528" width="371"]]306 +[[image:1732214207026-822.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="528" width="371"]] 301 301 302 302 In this section: 303 303 ... ... @@ -325,13 +325,13 @@ 325 325 If there is the "Short circuit" error, the **charging **relay opens (the “Switch off the charging relay on error” flag is set) and the **discharging **relay opens (the “Switch off the discharging relay on error flag” is set). 326 326 ))) 327 327 328 -== 3.6.11Contactor high temperature protection ==334 +=== Contactor high temperature protection === 329 329 330 330 The BMS protects power contactors from overheating. To measure the temperature of the contactor, a thermistor is used, connected to the P13 connector of the board. Configuring of the analog input for temperature measurement is described in section Input signals. 331 331 332 332 To change the overheating protection parameters of power contactors, select the menu "Protections → Contactor high temperature protection": 333 333 334 -[[ Contactor high temperature protection settings>>image:1732214237851-405.png||data-xwiki-image-style-alignment="center" height="234" width="336"]]340 +[[image:1732214237851-405.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="234" width="336"]] 335 335 336 336 In this section: 337 337 ... ... @@ -356,16 +356,16 @@ 356 356 357 357 (% class="box infomessage" %) 358 358 ((( 359 -If there is the "Contactor high temperature" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 365 +If there is the "Contactor high temperature" error, the **charging **relay opens (the “Switch off the charging relay on error” flag is set) and the **discharging **relay opens (the “Switch off the discharging relay on error flag” is set). 360 360 ))) 361 361 362 -== 3.6.12Unallowable charging protection ==368 +=== Unallowable charging protection === 363 363 364 364 The BMS can detect that the battery is charging through the discharging circuit and protectively open the discharging relay to prevent unallowable battery operation. 365 365 366 366 To change the parameters of the unallowable charging protection, select the menu "Protections → Unallowable charging protection": 367 367 368 -[[ Unallowable charging protection settings>>image:1732214272022-547.png||data-xwiki-image-style-alignment="center" height="145" width="312"]]374 +[[image:1732214272022-547.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="145" width="312"]] 369 369 370 370 In this section: 371 371 ... ... @@ -386,16 +386,16 @@ 386 386 387 387 (% class="box infomessage" %) 388 388 ((( 389 -If there is the "Unallowable charging" error, the discharging relay opens. 395 +If there is the "Unallowable charging" error, the **discharging **relay opens. 390 390 ))) 391 391 392 -== 3.6.13Stuck contactor protection ==398 +=== Stuck contactor protection === 393 393 394 394 The BMS Main 2.x protects contactors against sticking. 395 395 396 396 To change the protection parameters against sticking, select the menu "Protections → Stuck contactor protection": 397 397 398 -[[ Stuck contactor protection settings>>image:1732214367207-318.png||data-xwiki-image-style-alignment="center" height="152" width="331"]]404 +[[image:1732214367207-318.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="152" width="331"]] 399 399 400 400 In this section: 401 401 ... ... @@ -410,13 +410,18 @@ 410 410 411 411 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 412 412 413 -== 3.6.14 Contactor feedback check == 419 +(% class="box warningmessage" %) 420 +((( 421 +If there is the “Stuck contactor error”, the **“Critical error” **is generated and **all relays open.** 422 +))) 414 414 415 - TheBMS Main 2.x can receive feedback signals from contactorsand detect discrepancy between the control value and thefeedbacksignal. To enable specific contactor protection, one of thediscrete input must be set as corresponding contactor feedbacksignal (see section Input and output signals).424 +=== Contactor feedback check === 416 416 426 +The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see [[Input and output signals>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.3 Input and output signals.WebHome]]). 427 + 417 417 To change the contactor feedback check parameters, select the menu "Protections → Contactor feedback check": 418 418 419 -[[ Contactor feedback check settings>>image:1732214400721-274.png||data-xwiki-image-style-alignment="center" height="150" width="323"]]430 +[[image:1732214400721-274.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="150" width="323"]] 420 420 421 421 In this section: 422 422 ... ... @@ -429,13 +429,18 @@ 429 429 430 430 * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 431 431 432 -== 3.6.15 Charging contactor cycles protection == 443 +(% class="box warningmessage" %) 444 +((( 445 +If there is the contactor feedback error, the **“Critical error” **is generated and **all relays open.** 446 +))) 433 433 448 +=== Charging contactor cycles protection === 449 + 434 434 The BMS protects the charging contactor against frequent switching. 435 435 436 436 To change the protection parameters against high frequency switching of the charging contactor, select the menu "Protections → Charging contactor cycles protection": 437 437 438 -[[ Charging contactor cycles protection settings>>image:1732214432750-543.png||data-xwiki-image-style-alignment="center" height="260" width="336"]]454 +[[image:1732214432750-543.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="260" width="336"]] 439 439 440 440 In this section: 441 441 ... ... @@ -459,16 +459,16 @@ 459 459 460 460 (% class="box infomessage" %) 461 461 ((( 462 -If there is the "CH contactor cycles error" error, the charging relay opens. 478 +If there is the "CH contactor cycles error" error, the **charging **relay opens. 463 463 ))) 464 464 465 -== 3.6.16Discharging contactor cycles protection ==481 +=== Discharging contactor cycles protection === 466 466 467 467 The BMS protects the discharging contactor against frequent switching. 468 468 469 469 To change the protection parameters against high frequency switching of the discharging contactor, select the menu "Protections → Discharging contactor cycles protection": 470 470 471 -[[ Discharging contactor cycles protection settings>>image:1732214468462-541.png||data-xwiki-image-style-alignment="center" height="269" width="346"]]487 +[[image:1732214468462-541.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="269" width="346"]] 472 472 473 473 In this section: 474 474 ... ... @@ -492,16 +492,16 @@ 492 492 493 493 (% class="box infomessage" %) 494 494 ((( 495 -If there is the "DCH contactor cycles error" error, the discharging relay opens. 511 +If there is the "DCH contactor cycles error" error, the **discharging **relay opens. 496 496 ))) 497 497 498 -== 3.6.17Temperature sensor error ==514 +=== Temperature sensor error === 499 499 500 500 The board is implemented to check the temperature sensors connection circuits. The circuits are checked for breakage and short-circuit. 501 501 502 502 To change the protection parameters of the temperature sensors circuits, select the menu "Protections → Temperature sensor error": 503 503 504 -[[ Temperature sensor error settings>>image:1732214501360-654.png||data-xwiki-image-style-alignment="center" height="154" width="334"]]520 +[[image:1732214501360-654.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="154" width="334"]] 505 505 506 506 In this section: 507 507 ... ... @@ -514,14 +514,14 @@ 514 514 515 515 (% class="box warningmessage" %) 516 516 ((( 517 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, **the “Critical error” is generated and all relays open.**533 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error” **is generated and **all relays open.** 518 518 ))) 519 519 520 -== 3.6.18Logic high temperature protection ==536 +=== Logic high temperature protection === 521 521 522 522 To change the overheating protection parameters of BMS Logic boards, select the menu "Protections → Logic high temperature protection": 523 523 524 -[[ Logic high temperature protection settings>>image:1732214545352-111.png||data-xwiki-image-style-alignment="center" height="156" width="309"]]540 +[[image:1732214545352-111.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="156" width="309"]] 525 525 526 526 In this section: 527 527 ... ... @@ -545,11 +545,11 @@ 545 545 Cell balancing is prohibited for overheated boards. 546 546 ))) 547 547 548 -== 3.6.19Logic offline protection ==564 +=== Logic offline protection === 549 549 550 550 To change the protection parameters from loss of communication with BMS Logic boards, select the menu "Protections → Logic offline protection": 551 551 552 -[[ Logic offline protection settings>>image:1732214579147-515.png||data-xwiki-image-style-alignment="center" height="107" width="204"]]568 +[[image:1732214579147-515.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="107" width="204"]] 553 553 554 554 In this section: 555 555 ... ... @@ -568,14 +568,14 @@ 568 568 569 569 (% class="box warningmessage" %) 570 570 ((( 571 -If there is the "Logic offline" error, **the “Critical error” is generated and all relays open.**587 +If there is the "Logic offline" error, the **“Critical error”** is generated and **all relays open.** 572 572 ))) 573 573 574 -== 3.6.20Cell count protection ==590 +=== Cell count protection === 575 575 576 576 To change the protection parameters from the mismatch of the number of cells to the set value, select the menu "Protections → Cell count protection": 577 577 578 -[[ Cell count protection settings>>image:1732214641606-453.png||data-xwiki-image-style-alignment="center" height="178" width="341"]]594 +[[image:1732214641606-453.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="178" width="341"]] 579 579 580 580 In this section: 581 581 ... ... @@ -597,14 +597,14 @@ 597 597 598 598 (% class="box warningmessage" %) 599 599 ((( 600 -If there is the "Cell count error",** the “Critical error” is generated and all relays open.** 616 +If there is the "Cell count error",** **the **“Critical error”** is generated and **all relays open.** 601 601 ))) 602 602 603 -== 3.6.21Logic count protection ==619 +=== Logic count protection === 604 604 605 605 To change the protection parameters from the mismatch of the number of BMS Logic boards to the set value, select the menu "Protections → Logic count protection": 606 606 607 -[[ Logic count protection settings>>image:1732214675358-202.png||data-xwiki-image-style-alignment="center" height="163" width="230"]]623 +[[image:1732214675358-202.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="230"]] 608 608 609 609 In this section: 610 610 ... ... @@ -625,16 +625,16 @@ 625 625 626 626 (% class="box warningmessage" %) 627 627 ((( 628 -If there is the "Logic count error", **the “Critical error” is generated and all relays open.**644 +If there is the "Logic count error", the **“Critical error” **is generated and **all relays open.** 629 629 ))) 630 630 631 -== 3.6.22WDT protection ==647 +=== WDT protection === 632 632 633 633 If the BMS firmware hangs, the watchdog timer resets the board. The BMS can detect that the board was reset and generates the “WDT reset” error. 634 634 635 635 To change the parameters of the watchdog protection, select the menu "Protections → WDT protection": 636 636 637 -[[ WDT protection settings>>image:1732214703914-144.png||data-xwiki-image-style-alignment="center" height="127" width="323"]]653 +[[image:1732214703914-144.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="323"]] 638 638 639 639 In this section: 640 640 ... ... @@ -648,16 +648,16 @@ 648 648 649 649 (% class="box warningmessage" %) 650 650 ((( 651 -If there is the "WDT reset" error, **the “Critical error” is generated and667 +If there is the "WDT reset" error, the **“Critical error”** is generated and** all relays open.** 652 652 ))) 653 653 654 -== 3.6.23Insulation monitoring ==670 +=== Insulation monitoring === 655 655 656 656 BMS Main 2.x can detect a signal from an external insulation monitoring device (such as Bender IR155) to monitor the insulation quality. 657 657 658 658 To change the insulation monitoring parameters, select the menu "Protections → Insulation monitoring": 659 659 660 -[[ Insulationmonitoring settings>>image:1732214731490-961.png||data-xwiki-image-style-alignment="center" height="162" width="315"]]676 +[[image:1732214731490-961.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="315"]] 661 661 662 662 In this section: 663 663 ... ... @@ -668,11 +668,16 @@ 668 668 669 669 Error is set if corresponding discrete input is set up and it received logical zero. 670 670 671 -== 3.6.24 Critical error parameters == 687 +(% class="box warningmessage" %) 688 +((( 689 +If there is the "Insulation monitoring" error, the **“Critical error”** is generated and** all relays open.** 690 +))) 672 672 692 +=== Critical error parameters === 693 + 673 673 To change the critical error parameters, select the menu "Protections → Critical error parameters": 674 674 675 -[[ Critical error parameters settings>>image:1732214761141-983.png||data-xwiki-image-style-alignment="center" height="158" width="348"]]696 +[[image:1732214761141-983.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="348"]] 676 676 677 677 In this section: 678 678 ... ... @@ -692,10 +692,13 @@ 692 692 * “No temp. sensors”; 693 693 * “Temp. sensor is shorted”; 694 694 * “Current sensor error”; 716 +* "Stuck contactor"; 717 +* "Contactor feedback"; 695 695 * “Shunt offline”; 696 696 * “Shunt error”; 697 697 * “Settings error”; 698 -* “WDT reset”. 721 +* “WDT reset” 722 +* "Insulation monitoring". 699 699 700 700 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 701 701 ... ... @@ -704,11 +704,11 @@ 704 704 **If there is the “Critical error”, all relays open.** 705 705 ))) 706 706 707 -== 3.6.25General error parameters ==731 +=== General error parameters === 708 708 709 709 To change the general error parameters, select the menu "Protections → General error parameters": 710 710 711 -[[ General error parameters settings>>image:1732214987517-111.png||data-xwiki-image-style-alignment="center" height="535" width="349"]]735 +[[image:1732214987517-111.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="535" width="349"]] 712 712 713 713 In this section: 714 714 ... ... @@ -722,13 +722,16 @@ 722 722 723 723 The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time. 724 724 749 +(% class="box infomessage" %) 750 +((( 725 725 The "General error" is //indicative //and can be linked to any discrete output of the board. 752 +))) 726 726 727 -== 3.6.26Low SOC signal ==754 +=== Low SOC signal === 728 728 729 729 To change the parameters of the generation a signal about low battery level, select the menu "Protections → Low SOC signal": 730 730 731 -[[ Low SOC signal settings>>image:1732215174961-645.png||data-xwiki-image-style-alignment="center" height="186" width="325"]]758 +[[image:1732215174961-645.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="186" width="325"]] 732 732 733 733 In this section: 734 734 ... ... @@ -747,13 +747,16 @@ 747 747 748 748 * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 749 749 777 +(% class="box infomessage" %) 778 +((( 750 750 The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board. 780 +))) 751 751 752 -== 3.6.27High charging current signal ==782 +=== High charging current signal === 753 753 754 754 To change the parameters of the generation high-current signal, select the menu "Protections → High charging current signal": 755 755 756 -[[ High charging current signal settings>>image:1732215211714-445.png||data-xwiki-image-style-alignment="center" height="181" width="322"]]786 +[[image:1732215211714-445.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="181" width="322"]] 757 757 758 758 In this section: 759 759 ... ... @@ -772,13 +772,16 @@ 772 772 773 773 * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 774 774 805 +(% class="box infomessage" %) 806 +((( 775 775 The "High charging current" signal is //indicative //and can be linked to any discrete output of the board. 808 +))) 776 776 777 -== 3.6.28Heater control ==810 +=== Heater control === 778 778 779 779 To change the parameters of the heater control algorithm, select the menu "Protections → Heater control": 780 780 781 -[[ Heater control settings>>image:1732215252650-791.png||data-xwiki-image-style-alignment="center" height="233" width="370"]]814 +[[image:1732215252650-791.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="233" width="370"]] 782 782 783 783 In this section: 784 784 ... ... @@ -802,14 +802,14 @@ 802 802 803 803 (% class="box infomessage" %) 804 804 ((( 805 -If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 838 +If there is the "Heater" signal, the **heater **relay closes and/or a signal is output to the corresponded digital output. 806 806 ))) 807 807 808 -== 3.6.29Heater (AUX) control ==841 +=== Heater (AUX) control === 809 809 810 810 To change the parameters of the auxiliary heater control algorithm, select the menu "Protections → Heater (AUX) control": 811 811 812 -[[ Heater (AUX) control settings>>image:1732215282135-420.png||data-xwiki-image-style-alignment="center" height="228" width="361"]]845 +[[image:1732215282135-420.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="228" width="361"]] 813 813 814 814 In this section: 815 815 ... ... @@ -833,14 +833,14 @@ 833 833 834 834 (% class="box infomessage" %) 835 835 ((( 836 -If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output. 869 +If there is the "Heater (AUX)" signal, the **auxiliary heater **relay closes and/or a signal is output to the corresponded digital output. 837 837 ))) 838 838 839 -== 3.6.30Cooler control ==872 +=== Cooler control === 840 840 841 841 To change the parameters of the cooler control algorithm, select the menu "Protections → Cooler control": 842 842 843 -[[ Cooler control settings>>image:1732215313977-499.png||data-xwiki-image-style-alignment="center" height="219" width="348"]]876 +[[image:1732215313977-499.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="219" width="348"]] 844 844 845 845 In this section: 846 846 ... ... @@ -864,50 +864,15 @@ 864 864 865 865 (% class="box infomessage" %) 866 866 ((( 867 -If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output. 900 +If there is the "Cooler" signal, the **cooler **relay closes and/or a signal is output to the corresponded digital output. 868 868 ))) 869 869 870 -== 3.6.31Fault simulation ==903 +=== Fault simulation === 871 871 872 872 The board provides the ability to manually generate error flags bypassing the protection algorithms. This functionality is intended for commissioning. 873 873 874 874 To simulate battery and BMS errors, select the menu "Protections → Fault simulation": 875 875 876 -[[ Fault simulation settings>>image:1732215359330-850.png||data-xwiki-image-style-alignment="center" height="732" width="204"]]909 +[[image:1732215359330-850.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="732" width="204"]] 877 877 878 -In this section: 879 - 880 -* Overcurrent; 881 -* Undervoltage; 882 -* Overvoltage; 883 -* Low CH temperature; 884 -* Low DCH temperature; 885 -* High CH temperature; 886 -* High DCH temperature; 887 -* Battery cover error; 888 -* High humidity; 889 -* Water; 890 -* Current sensor error; 891 -* Short circuit; 892 -* Contactor high temperature; 893 -* Unallowable charging; 894 -* Stuck contactor; 895 -* CH contactor feedback error; 896 -* DCH contactor feedback error; 897 -* PCH contactor feedback error; 898 -* CH/DCH contactor feedback error; 899 -* Main contactor feedback error; 900 -* CH contactor cycles error; 901 -* DCH contactor cycles error; 902 -* Logic high temperature; 903 -* Logic offline; 904 -* Cell count error; 905 -* Logic count error; 906 -* Insulation error; 907 -* Critical error; 908 -* Low SOC; 909 -* High charging current; 910 -* Heater; 911 -* Cooler. 912 - 913 913 To simulate errors, set the necessary flags and click on the "Save" button.