Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -356,7 +356,7 @@ 356 356 357 357 (% class="box infomessage" %) 358 358 ((( 359 -If there is the "Contactor high temperature" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 359 +If there is the "Contactor high temperature" error, the **charging **relay opens (the “Switch off the charging relay on error” flag is set) and the **discharging **relay opens (the “Switch off the discharging relay on error flag” is set). 360 360 ))) 361 361 362 362 == 3.6.12 Unallowable charging protection == ... ... @@ -386,7 +386,7 @@ 386 386 387 387 (% class="box infomessage" %) 388 388 ((( 389 -If there is the "Unallowable charging" error, the discharging relay opens. 389 +If there is the "Unallowable charging" error, the **discharging **relay opens. 390 390 ))) 391 391 392 392 == 3.6.13 Stuck contactor protection == ... ... @@ -410,6 +410,7 @@ 410 410 411 411 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 412 412 413 + 413 413 == 3.6.14 Contactor feedback check == 414 414 415 415 The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see section Input and output signals). ... ... @@ -429,6 +429,7 @@ 429 429 430 430 * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 431 431 433 + 432 432 == 3.6.15 Charging contactor cycles protection == 433 433 434 434 The BMS protects the charging contactor against frequent switching. ... ... @@ -459,7 +459,7 @@ 459 459 460 460 (% class="box infomessage" %) 461 461 ((( 462 -If there is the "CH contactor cycles error" error, the charging relay opens. 464 +If there is the "CH contactor cycles error" error, the **charging **relay opens. 463 463 ))) 464 464 465 465 == 3.6.16 Discharging contactor cycles protection == ... ... @@ -492,7 +492,7 @@ 492 492 493 493 (% class="box infomessage" %) 494 494 ((( 495 -If there is the "DCH contactor cycles error" error, the discharging relay opens. 497 +If there is the "DCH contactor cycles error" error, the **discharging **relay opens. 496 496 ))) 497 497 498 498 == 3.6.17 Temperature sensor error ==