... ... @@ -63,7 +63,7 @@
63 63  
64 64  (% class="box infomessage" %)
65 65  (((
66 -If there is the "Undervoltage" error, the discharging relay opens.
66 +If there is the "Undervoltage" error, the **discharging **relay opens.
67 67  )))
68 68  
69 69  3.6.3 Overvoltage protection
... ... @@ -94,7 +94,7 @@
94 94  
95 95  (% class="box infomessage" %)
96 96  (((
97 -If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set).
97 +If there is the "Overvoltage" error, the **charging **relay and **discharging **relay opens (if the “Switch off the discharging relay on error” flag is set).
98 98  )))
99 99  
100 100  == 3.6.4 Low temperature protection ==
... ... @@ -128,8 +128,8 @@
128 128  
129 129  (% class="box infomessage" %)
130 130  (((
131 -If there is the "Low CH temperature" error, the charging relay opens.
132 -If there is the "Low DCH temperature" error, the discharging relay opens.
131 +If there is the "Low CH temperature" error, the **charging **relay opens.
132 +If there is the "Low DCH temperature" error, the **discharging **relay opens.
133 133  )))
134 134  
135 135  == 3.6.5 High temperature protection ==
... ... @@ -163,8 +163,8 @@
163 163  
164 164  (% class="box infomessage" %)
165 165  (((
166 -If there is the "High CH temperature" error, the charging relay opens.
167 -If there is the "High DCH temperature" error, the discharging relay opens.
166 +If there is the "High CH temperature" error, the **charging **relay opens.
167 +If there is the "High DCH temperature" error, the **discharging **relay opens.
168 168  )))
169 169  
170 170  == 3.6.6 Battery cover protection ==
... ... @@ -192,7 +192,7 @@
192 192  
193 193  (% class="box warningmessage" %)
194 194  (((
195 -If there is the "Battery cover error", **the “Critical error” is generated and all relays open.**
195 +If there is the "Battery cover error", the **“Critical error” **is generated and **all relays open.**
196 196  )))
197 197  
198 198  == 3.6.7 High humidity protection ==
... ... @@ -254,7 +254,7 @@
254 254  
255 255  (% class="box warningmessage" %)
256 256  (((
257 -If there is the “Water” error,** the “Critical error” is generated and all relays open.**
257 +If there is the “Water” error,** **the **“Critical error”** is generated and **all relays open.**
258 258  )))
259 259  
260 260  == 3.6.9 Current sensor error ==
... ... @@ -288,7 +288,7 @@
288 288  
289 289  (% class="box warningmessage" %)
290 290  (((
291 -If there is the “Current sensor error”, **the “Critical error” is generated and all relays open.**
291 +If there is the “Current sensor error”, the **“Critical error” **is generated and **all relays open.**
292 292  )))
293 293  
294 294  == 3.6.10 Short circuit protection ==
... ... @@ -322,7 +322,7 @@
322 322  
323 323  (% class="box infomessage" %)
324 324  (((
325 -If there is the "Short circuit" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set).
325 +If there is the "Short circuit" error, the **charging **relay opens (the “Switch off the charging relay on error” flag is set) and the **discharging **relay opens (the “Switch off the discharging relay on error flag” is set).
326 326  )))
327 327  
328 328  == 3.6.11 Contactor high temperature protection ==