... ... @@ -31,7 +31,7 @@
31 31  
32 32  (% class="box infomessage" %)
33 33  (((
34 -If there is the "Overcurrent" error, the **charging **and **discharging **relay open.
34 +If there is the "Overcurrent" error, the charging and discharging relay open.
35 35  )))
36 36  
37 37  == 3.6.2 Undervoltage protection ==
... ... @@ -192,7 +192,7 @@
192 192  
193 193  (% class="box warningmessage" %)
194 194  (((
195 -If there is the "Battery cover error", **the “Critical error” is generated and all relays open.**
195 +**If there is the "Battery cover error", the “Critical error” is generated and all relays open.**
196 196  )))
197 197  
198 198  == 3.6.7 High humidity protection ==
... ... @@ -254,7 +254,7 @@
254 254  
255 255  (% class="box warningmessage" %)
256 256  (((
257 -If there is the “Water” error,** the “Critical error” is generated and all relays open.**
257 +**If there is the “Water” error, the “Critical error” is generated and all relays open.**
258 258  )))
259 259  
260 260  == 3.6.9 Current sensor error ==
... ... @@ -288,7 +288,7 @@
288 288  
289 289  (% class="box warningmessage" %)
290 290  (((
291 -If there is the “Current sensor error”, **the “Critical error” is generated and all relays open.**
291 +**If there is the “Current sensor error”, the “Critical error” is generated and all relays open.**
292 292  )))
293 293  
294 294  == 3.6.10 Short circuit protection ==
... ... @@ -514,7 +514,7 @@
514 514  
515 515  (% class="box warningmessage" %)
516 516  (((
517 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, **the “Critical error” is generated and all relays open.**
517 +**If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the “Critical error” is generated and all relays open.**
518 518  )))
519 519  
520 520  == 3.6.18 Logic high temperature protection ==
... ... @@ -542,7 +542,7 @@
542 542  
543 543  (% class="box infomessage" %)
544 544  (((
545 -Cell balancing is prohibited for overheated boards.
545 +**Cell balancing is prohibited for overheated boards.**
546 546  )))
547 547  
548 548  == 3.6.19 Logic offline protection ==
... ... @@ -568,7 +568,7 @@
568 568  
569 569  (% class="box warningmessage" %)
570 570  (((
571 -If there is the "Logic offline" error, **the “Critical error” is generated and all relays open.**
571 +**If there is the "Logic offline" error, the “Critical error” is generated and all relays open.**
572 572  )))
573 573  
574 574  == 3.6.20 Cell count protection ==
... ... @@ -597,7 +597,7 @@
597 597  
598 598  (% class="box warningmessage" %)
599 599  (((
600 -If there is the "Cell count error",** the “Critical error” is generated and all relays open.**
600 +**If there is the "Cell count error", the “Critical error” is generated and all relays open.**
601 601  )))
602 602  
603 603  == 3.6.21 Logic count protection ==
... ... @@ -625,7 +625,7 @@
625 625  
626 626  (% class="box warningmessage" %)
627 627  (((
628 -If there is the "Logic count error", **the “Critical error” is generated and all relays open.**
628 +**If there is the "Logic count error", the “Critical error” is generated and all relays open.**
629 629  )))
630 630  
631 631  == 3.6.22 WDT protection ==
... ... @@ -648,7 +648,7 @@
648 648  
649 649  (% class="box warningmessage" %)
650 650  (((
651 -If there is the "WDT reset" error, **the “Critical error” is generated and all relays open.**
651 +**If there is the "WDT reset" error, the “Critical error” is generated and all relays open.**
652 652  )))
653 653  
654 654  == 3.6.23 Insulation monitoring ==
... ... @@ -778,7 +778,7 @@
778 778  
779 779  To change the parameters of the heater control algorithm, select the menu "Protections → Heater control":
780 780  
781 -[[Heater control settings>>image:1732215252650-791.png||data-xwiki-image-style-alignment="center" height="233" width="370"]]
781 +[[image:1732215252650-791.png]]
782 782  
783 783  In this section:
784 784  
... ... @@ -809,7 +809,6 @@
809 809  
810 810  To change the parameters of the auxiliary heater control algorithm, select the menu "Protections → Heater (AUX) control":
811 811  
812 -[[Heater (AUX) control settings>>image:1732215282135-420.png||data-xwiki-image-style-alignment="center" height="228" width="361"]]
813 813  
814 814  In this section:
815 815  
... ... @@ -840,7 +840,6 @@
840 840  
841 841  To change the parameters of the cooler control algorithm, select the menu "Protections → Cooler control":
842 842  
843 -[[Cooler control settings>>image:1732215313977-499.png||data-xwiki-image-style-alignment="center" height="219" width="348"]]
844 844  
845 845  In this section:
846 846  
... ... @@ -873,7 +873,6 @@
873 873  
874 874  To simulate battery and BMS errors, select the menu "Protections → Fault simulation":
875 875  
876 -[[Fault simulation settings>>image:1732215359330-850.png||data-xwiki-image-style-alignment="center" height="732" width="204"]]
877 877  
878 878  In this section:
879 879  
1732215313977-499.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -17.8 KB
Content
1732215359330-850.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -31.8 KB
Content