Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -356,7 +356,7 @@ 356 356 357 357 (% class="box infomessage" %) 358 358 ((( 359 -If there is the "Contactor high temperature" error, the **charging**relay opens (the “Switch off the charging relay on error” flag is set) and the**discharging**relay opens (the “Switch off the discharging relay on error flag” is set).359 +If there is the "Contactor high temperature" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 360 360 ))) 361 361 362 362 == 3.6.12 Unallowable charging protection == ... ... @@ -386,7 +386,7 @@ 386 386 387 387 (% class="box infomessage" %) 388 388 ((( 389 -If there is the "Unallowable charging" error, the **discharging**relay opens.389 +If there is the "Unallowable charging" error, the discharging relay opens. 390 390 ))) 391 391 392 392 == 3.6.13 Stuck contactor protection == ... ... @@ -410,11 +410,6 @@ 410 410 411 411 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 412 412 413 -(% class="box warningmessage" %) 414 -((( 415 -If there is the “Stuck contactor error”, the **“Critical error” **is generated and **all relays open.** 416 -))) 417 - 418 418 == 3.6.14 Contactor feedback check == 419 419 420 420 The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see section Input and output signals). ... ... @@ -434,11 +434,6 @@ 434 434 435 435 * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 436 436 437 -(% class="box warningmessage" %) 438 -((( 439 -If there is the contactor feedback error, the **“Critical error” **is generated and **all relays open.** 440 -))) 441 - 442 442 == 3.6.15 Charging contactor cycles protection == 443 443 444 444 The BMS protects the charging contactor against frequent switching. ... ... @@ -469,7 +469,7 @@ 469 469 470 470 (% class="box infomessage" %) 471 471 ((( 472 -If there is the "CH contactor cycles error" error, the **charging**relay opens.462 +If there is the "CH contactor cycles error" error, the charging relay opens. 473 473 ))) 474 474 475 475 == 3.6.16 Discharging contactor cycles protection == ... ... @@ -502,7 +502,7 @@ 502 502 503 503 (% class="box infomessage" %) 504 504 ((( 505 -If there is the "DCH contactor cycles error" error, the **discharging**relay opens.495 +If there is the "DCH contactor cycles error" error, the discharging relay opens. 506 506 ))) 507 507 508 508 == 3.6.17 Temperature sensor error == ... ... @@ -524,7 +524,7 @@ 524 524 525 525 (% class="box warningmessage" %) 526 526 ((( 527 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”**is generated and**all relays open.**517 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, **the “Critical error” is generated and all relays open.** 528 528 ))) 529 529 530 530 == 3.6.18 Logic high temperature protection == ... ... @@ -578,7 +578,7 @@ 578 578 579 579 (% class="box warningmessage" %) 580 580 ((( 581 -If there is the "Logic offline" error, the **“Critical error”**is generated and**all relays open.**571 +If there is the "Logic offline" error, **the “Critical error” is generated and all relays open.** 582 582 ))) 583 583 584 584 == 3.6.20 Cell count protection == ... ... @@ -607,7 +607,7 @@ 607 607 608 608 (% class="box warningmessage" %) 609 609 ((( 610 -If there is the "Cell count error",** **the**“Critical error”**is generated and**all relays open.**600 +If there is the "Cell count error",** the “Critical error” is generated and all relays open.** 611 611 ))) 612 612 613 613 == 3.6.21 Logic count protection == ... ... @@ -635,7 +635,7 @@ 635 635 636 636 (% class="box warningmessage" %) 637 637 ((( 638 -If there is the "Logic count error", the **“Critical error”**is generated and**all relays open.**628 +If there is the "Logic count error", **the “Critical error” is generated and all relays open.** 639 639 ))) 640 640 641 641 == 3.6.22 WDT protection == ... ... @@ -658,7 +658,7 @@ 658 658 659 659 (% class="box warningmessage" %) 660 660 ((( 661 -If there is the "WDT reset" error, the **“Critical error”**is generated and**all relays open.**651 +If there is the "WDT reset" error, **the “Critical error” is generated and all relays open.** 662 662 ))) 663 663 664 664 == 3.6.23 Insulation monitoring == ... ... @@ -678,11 +678,6 @@ 678 678 679 679 Error is set if corresponding discrete input is set up and it received logical zero. 680 680 681 -(% class="box warningmessage" %) 682 -((( 683 -If there is the "Insulation monitoring" error, the **“Critical error”** is generated and** all relays open.** 684 -))) 685 - 686 686 == 3.6.24 Critical error parameters == 687 687 688 688 To change the critical error parameters, select the menu "Protections → Critical error parameters": ... ... @@ -707,12 +707,10 @@ 707 707 * “No temp. sensors”; 708 708 * “Temp. sensor is shorted”; 709 709 * “Current sensor error”; 710 -* " 711 711 * “Shunt offline”; 712 712 * “Shunt error”; 713 713 * “Settings error”; 714 -* “WDT reset” 715 -* "Insulation monitoring". 698 +* “WDT reset”. 716 716 717 717 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 718 718 ... ... @@ -739,10 +739,7 @@ 739 739 740 740 The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time. 741 741 742 -(% class="box infomessage" %) 743 -((( 744 744 The "General error" is //indicative //and can be linked to any discrete output of the board. 745 -))) 746 746 747 747 == 3.6.26 Low SOC signal == 748 748 ... ... @@ -767,10 +767,7 @@ 767 767 768 768 * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 769 769 770 -(% class="box infomessage" %) 771 -((( 772 772 The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board. 773 -))) 774 774 775 775 == 3.6.27 High charging current signal == 776 776 ... ... @@ -795,10 +795,7 @@ 795 795 796 796 * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 797 797 798 -(% class="box infomessage" %) 799 -((( 800 800 The "High charging current" signal is //indicative //and can be linked to any discrete output of the board. 801 -))) 802 802 803 803 == 3.6.28 Heater control == 804 804 ... ... @@ -828,7 +828,7 @@ 828 828 829 829 (% class="box infomessage" %) 830 830 ((( 831 -If there is the "Heater" signal, the **heater**relay closes and/or a signal is output to the corresponded digital output.805 +If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 832 832 ))) 833 833 834 834 == 3.6.29 Heater (AUX) control == ... ... @@ -859,7 +859,7 @@ 859 859 860 860 (% class="box infomessage" %) 861 861 ((( 862 -If there is the "Heater (AUX)" signal, the **auxiliary heater**relay closes and/or a signal is output to the corresponded digital output.836 +If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output. 863 863 ))) 864 864 865 865 == 3.6.30 Cooler control == ... ... @@ -890,7 +890,7 @@ 890 890 891 891 (% class="box infomessage" %) 892 892 ((( 893 -If there is the "Cooler" signal, the **cooler**relay closes and/or a signal is output to the corresponded digital output.867 +If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output. 894 894 ))) 895 895 896 896 == 3.6.31 Fault simulation ==