Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -31,7 +31,7 @@ 31 31 32 32 (% class="box infomessage" %) 33 33 ((( 34 -If there is the "Overcurrent" error, the charging and discharging relay open. 34 +If there is the "Overcurrent" error, the **charging **and **discharging **relay open. 35 35 ))) 36 36 37 37 == 3.6.2 Undervoltage protection == ... ... @@ -192,7 +192,7 @@ 192 192 193 193 (% class="box warningmessage" %) 194 194 ((( 195 - **If there is the "Battery cover error", the “Critical error” is generated and all relays open.**195 +If there is the "Battery cover error", **the “Critical error” is generated and all relays open.** 196 196 ))) 197 197 198 198 == 3.6.7 High humidity protection == ... ... @@ -254,7 +254,7 @@ 254 254 255 255 (% class="box warningmessage" %) 256 256 ((( 257 - **If there is the “Water” error, the “Critical error” is generated and all relays open.**257 +If there is the “Water” error,** the “Critical error” is generated and all relays open.** 258 258 ))) 259 259 260 260 == 3.6.9 Current sensor error == ... ... @@ -288,7 +288,7 @@ 288 288 289 289 (% class="box warningmessage" %) 290 290 ((( 291 - **If there is the “Current sensor error”, the “Critical error” is generated and all relays open.**291 +If there is the “Current sensor error”, **the “Critical error” is generated and all relays open.** 292 292 ))) 293 293 294 294 == 3.6.10 Short circuit protection == ... ... @@ -514,7 +514,7 @@ 514 514 515 515 (% class="box warningmessage" %) 516 516 ((( 517 - **If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the “Critical error” is generated and all relays open.**517 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, **the “Critical error” is generated and all relays open.** 518 518 ))) 519 519 520 520 == 3.6.18 Logic high temperature protection == ... ... @@ -542,7 +542,7 @@ 542 542 543 543 (% class="box infomessage" %) 544 544 ((( 545 - **Cell balancing is prohibited for overheated boards.**545 +Cell balancing is prohibited for overheated boards. 546 546 ))) 547 547 548 548 == 3.6.19 Logic offline protection == ... ... @@ -568,7 +568,7 @@ 568 568 569 569 (% class="box warningmessage" %) 570 570 ((( 571 - **If there is the "Logic offline" error, the “Critical error” is generated and all relays open.**571 +If there is the "Logic offline" error, **the “Critical error” is generated and all relays open.** 572 572 ))) 573 573 574 574 == 3.6.20 Cell count protection == ... ... @@ -597,7 +597,7 @@ 597 597 598 598 (% class="box warningmessage" %) 599 599 ((( 600 - **If there is the "Cell count error", the “Critical error” is generated and all relays open.**600 +If there is the "Cell count error",** the “Critical error” is generated and all relays open.** 601 601 ))) 602 602 603 603 == 3.6.21 Logic count protection == ... ... @@ -625,7 +625,7 @@ 625 625 626 626 (% class="box warningmessage" %) 627 627 ((( 628 - **If there is the "Logic count error", the “Critical error” is generated and all relays open.**628 +If there is the "Logic count error", **the “Critical error” is generated and all relays open.** 629 629 ))) 630 630 631 631 == 3.6.22 WDT protection == ... ... @@ -648,7 +648,7 @@ 648 648 649 649 (% class="box warningmessage" %) 650 650 ((( 651 - **If there is the "WDT reset" error, the “Critical error” is generated and all relays open.**651 +If there is the "WDT reset" error, **the “Critical error” is generated and all relays open.** 652 652 ))) 653 653 654 654 == 3.6.23 Insulation monitoring == ... ... @@ -840,7 +840,7 @@ 840 840 841 841 To change the parameters of the cooler control algorithm, select the menu "Protections → Cooler control": 842 842 843 -[[Cooler control settin>>image:1732215313977-499.png||data-xwiki-image-style-alignment="center" height="19 8" width="315"]]843 +[[Cooler control settings>>image:1732215313977-499.png||data-xwiki-image-style-alignment="center" height="219" width="348"]] 844 844 845 845 In this section: 846 846 ... ... @@ -873,6 +873,7 @@ 873 873 874 874 To simulate battery and BMS errors, select the menu "Protections → Fault simulation": 875 875 876 +[[Fault simulation settings>>image:1732215359330-850.png||data-xwiki-image-style-alignment="center" height="732" width="204"]] 876 876 877 877 In this section: 878 878
- 1732215359330-850.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.8 KB - Content