... ... @@ -34,37 +34,3 @@
34 34  (((
35 35  If there is the "Overcurrent" error, the charging relay and discharging relay open.
36 36  )))
37 -
38 -== 3.6.2 Undervoltage protection ==
39 -
40 -The board implements battery protection from too low or too high voltage on the cells.
41 -
42 -To change the battery protection parameters from low voltage on the cells, select the menu "Protections → Undervoltage protection":
43 -
44 -[[Undervoltage protection settings>>image:1732212212350-294.png||data-xwiki-image-style-alignment="center" height="207" width="359"]]
45 -
46 - In this section:
47 -
48 -* Enable – a flag to enable the protection;
49 -* Minimum cell voltage, V;
50 -* Tolerant cell voltage, V;
51 -* Delay before setting the error, second;
52 -* Delay before clearing the error, second;
53 -* Lock the error until the device is reset.
54 -
55 -As a result of the operation of battery protection from low voltage, the "Undervoltage" error is generated.
56 -
57 -Error generation conditions:
58 -
59 -* the minimum voltage among all cells of the battery is less than the “Minimum cell voltage” value for the “Delay before setting the error” time.
60 -
61 -Conditions for removing the error:
62 -
63 -* the minimum voltage among all cells of the battery is greater than the “Tolerant cell voltage” value for the “Delay before clearing the error” time.
64 -
65 -(% class="box infomessage" %)
66 -(((
67 -If there is the "Undervoltage" error, the discharging relay opens.
68 -)))
69 -
70 -