... ... @@ -34,3 +34,70 @@ 34 34 ((( 35 35 If there is the "Overcurrent" error, the charging relay and discharging relay open. 36 36 ))) 37 + 38 +== 3.6.2 Undervoltage protection == 39 + 40 +The board implements battery protection from too low or too high voltage on the cells. 41 + 42 +To change the battery protection parameters from low voltage on the cells, select the menu "Protections → Undervoltage protection": 43 + 44 +[[Undervoltage protection settings>>image:1732212212350-294.png||data-xwiki-image-style-alignment="center" height="207" width="359"]] 45 + 46 + In this section: 47 + 48 +* Enable – a flag to enable the protection; 49 +* Minimum cell voltage, V; 50 +* Tolerant cell voltage, V; 51 +* Delay before setting the error, second; 52 +* Delay before clearing the error, second; 53 +* Lock the error until the device is reset. 54 + 55 +As a result of the operation of battery protection from low voltage, the "Undervoltage" error is generated. 56 + 57 +Error generation conditions: 58 + 59 +* the minimum voltage among all cells of the battery is less than the “Minimum cell voltage” value for the “Delay before setting the error” time. 60 + 61 +Conditions for removing the error: 62 + 63 +* the minimum voltage among all cells of the battery is greater than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 64 + 65 +(% class="box infomessage" %) 66 +((( 67 +If there is the "Undervoltage" error, the discharging relay opens. 68 +))) 69 + 70 +3.6.3 Overvoltage protection 71 + 72 +To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection": 73 + 74 +[[image:1732212357972-295.png]] 75 + 76 +In this section: 77 + 78 +* Enable – a flag to enable the protection; 79 +* Maximum cell voltage, V; 80 +* Tolerant cell voltage, V; 81 +* Delay before setting the error, second; 82 +* Delay before clearing the error, second; 83 +* Switch off the discharging relay on error – a flag to open the discharging relay when the "Overvoltage" error is generated; 84 +* Lock the error until the device is reset. 85 + 86 +As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. 87 + 88 +Error generation conditions: 89 + 90 +* the maximum voltage among all cells of the battery is greater than the “Maximum cell voltage” value for the “Delay before setting the error” time. 91 + 92 +Conditions for removing the error: 93 + 94 +* the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 95 + 96 +(% class="box infomessage" %) 97 +((( 98 +If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set). 99 +))) 100 + 101 +3.6.4 Low temperature protection 102 + 103 +3.6.5 High temperature protecti
- 1732212357972-295.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.5 KB - Content