Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 6 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -31,7 +31,7 @@ 31 31 32 32 (% class="box infomessage" %) 33 33 ((( 34 -If there is the "Overcurrent" error, the charging and discharging relay open. 34 +If there is the "Overcurrent" error, the **charging **and **discharging **relay open. 35 35 ))) 36 36 37 37 == 3.6.2 Undervoltage protection == ... ... @@ -63,7 +63,7 @@ 63 63 64 64 (% class="box infomessage" %) 65 65 ((( 66 -If there is the "Undervoltage" error, the discharging relay opens. 66 +If there is the "Undervoltage" error, the **discharging **relay opens. 67 67 ))) 68 68 69 69 3.6.3 Overvoltage protection ... ... @@ -94,7 +94,7 @@ 94 94 95 95 (% class="box infomessage" %) 96 96 ((( 97 -If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set). 97 +If there is the "Overvoltage" error, the **charging **relay and **discharging **relay opens (if the “Switch off the discharging relay on error” flag is set). 98 98 ))) 99 99 100 100 == 3.6.4 Low temperature protection == ... ... @@ -128,8 +128,8 @@ 128 128 129 129 (% class="box infomessage" %) 130 130 ((( 131 -If there is the "Low CH temperature" error, the charging relay opens. 132 -If there is the "Low DCH temperature" error, the discharging relay opens. 131 +If there is the "Low CH temperature" error, the **charging **relay opens. 132 +If there is the "Low DCH temperature" error, the **discharging **relay opens. 133 133 ))) 134 134 135 135 == 3.6.5 High temperature protection == ... ... @@ -163,8 +163,8 @@ 163 163 164 164 (% class="box infomessage" %) 165 165 ((( 166 -If there is the "High CH temperature" error, the charging relay opens. 167 -If there is the "High DCH temperature" error, the discharging relay opens. 166 +If there is the "High CH temperature" error, the **charging **relay opens. 167 +If there is the "High DCH temperature" error, the **discharging **relay opens. 168 168 ))) 169 169 170 170 == 3.6.6 Battery cover protection == ... ... @@ -192,7 +192,7 @@ 192 192 193 193 (% class="box warningmessage" %) 194 194 ((( 195 - **If there is the "Battery cover error", the “Critical error” is generated and all relays open.**195 +If there is the "Battery cover error", the **“Critical error” **is generated and **all relays open.** 196 196 ))) 197 197 198 198 == 3.6.7 High humidity protection == ... ... @@ -254,7 +254,7 @@ 254 254 255 255 (% class="box warningmessage" %) 256 256 ((( 257 - **If there is the “Water” error, the “Critical error” is generated and all relays open.**257 +If there is the “Water” error,** **the **“Critical error”** is generated and **all relays open.** 258 258 ))) 259 259 260 260 == 3.6.9 Current sensor error == ... ... @@ -288,7 +288,7 @@ 288 288 289 289 (% class="box warningmessage" %) 290 290 ((( 291 - **If there is the “Current sensor error”, the “Critical error” is generated and all relays open.**291 +If there is the “Current sensor error”, the **“Critical error” **is generated and **all relays open.** 292 292 ))) 293 293 294 294 == 3.6.10 Short circuit protection == ... ... @@ -322,7 +322,7 @@ 322 322 323 323 (% class="box infomessage" %) 324 324 ((( 325 -If there is the "Short circuit" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 325 +If there is the "Short circuit" error, the **charging **relay opens (the “Switch off the charging relay on error” flag is set) and the **discharging **relay opens (the “Switch off the discharging relay on error flag” is set). 326 326 ))) 327 327 328 328 == 3.6.11 Contactor high temperature protection == ... ... @@ -514,7 +514,7 @@ 514 514 515 515 (% class="box warningmessage" %) 516 516 ((( 517 - **If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the “Critical error” is generated and all relays open.**517 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, **the “Critical error” is generated and all relays open.** 518 518 ))) 519 519 520 520 == 3.6.18 Logic high temperature protection == ... ... @@ -542,7 +542,7 @@ 542 542 543 543 (% class="box infomessage" %) 544 544 ((( 545 - **Cell balancing is prohibited for overheated boards.**545 +Cell balancing is prohibited for overheated boards. 546 546 ))) 547 547 548 548 == 3.6.19 Logic offline protection == ... ... @@ -568,7 +568,7 @@ 568 568 569 569 (% class="box warningmessage" %) 570 570 ((( 571 - **If there is the "Logic offline" error, the “Critical error” is generated and all relays open.**571 +If there is the "Logic offline" error, **the “Critical error” is generated and all relays open.** 572 572 ))) 573 573 574 574 == 3.6.20 Cell count protection == ... ... @@ -597,7 +597,7 @@ 597 597 598 598 (% class="box warningmessage" %) 599 599 ((( 600 - **If there is the "Cell count error", the “Critical error” is generated and all relays open.**600 +If there is the "Cell count error",** the “Critical error” is generated and all relays open.** 601 601 ))) 602 602 603 603 == 3.6.21 Logic count protection == ... ... @@ -625,7 +625,7 @@ 625 625 626 626 (% class="box warningmessage" %) 627 627 ((( 628 - **If there is the "Logic count error", the “Critical error” is generated and all relays open.**628 +If there is the "Logic count error", **the “Critical error” is generated and all relays open.** 629 629 ))) 630 630 631 631 == 3.6.22 WDT protection == ... ... @@ -648,7 +648,7 @@ 648 648 649 649 (% class="box warningmessage" %) 650 650 ((( 651 - **If there is the "WDT reset" error, the “Critical error” is generated and all relays open.**651 +If there is the "WDT reset" error, **the “Critical error” is generated and all relays open.** 652 652 ))) 653 653 654 654 == 3.6.23 Insulation monitoring == ... ... @@ -706,10 +706,29 @@ 706 706 707 707 == 3.6.25 General error parameters == 708 708 709 +To change the general error parameters, select the menu "Protections → General error parameters": 710 + 711 +[[General error parameters settings>>image:1732214987517-111.png||data-xwiki-image-style-alignment="center" height="535" width="349"]] 712 + 713 +In this section: 714 + 715 +* Enable – a flag to enable the protection; 716 +* Delay before setting the error, second; 717 +* Delay before clearing the error, second; 718 +* Lock the error until the device is reset; 719 +* Errors – a section to select errors that should trigger General error. 720 + 721 +The critical error flag is generated if at least one of the selected errors is generated during the “Delay before setting the error” time. 722 + 723 +The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time. 724 + 725 +The "General error" is //indicative //and can be linked to any discrete output of the board. 726 + 709 709 == 3.6.26 Low SOC signal == 710 710 711 711 To change the parameters of the generation a signal about low battery level, select the menu "Protections → Low SOC signal": 712 712 731 +[[Low SOC signal settings>>image:1732215174961-645.png||data-xwiki-image-style-alignment="center" height="186" width="325"]] 713 713 714 714 In this section: 715 715 ... ... @@ -734,6 +734,7 @@ 734 734 735 735 To change the parameters of the generation high-current signal, select the menu "Protections → High charging current signal": 736 736 756 +[[High charging current signal settings>>image:1732215211714-445.png||data-xwiki-image-style-alignment="center" height="181" width="322"]] 737 737 738 738 In this section: 739 739 ... ... @@ -758,6 +758,7 @@ 758 758 759 759 To change the parameters of the heater control algorithm, select the menu "Protections → Heater control": 760 760 781 +[[Heater control settings>>image:1732215252650-791.png||data-xwiki-image-style-alignment="center" height="233" width="370"]] 761 761 762 762 In this section: 763 763 ... ... @@ -788,6 +788,7 @@ 788 788 789 789 To change the parameters of the auxiliary heater control algorithm, select the menu "Protections → Heater (AUX) control": 790 790 812 +[[Heater (AUX) control settings>>image:1732215282135-420.png||data-xwiki-image-style-alignment="center" height="228" width="361"]] 791 791 792 792 In this section: 793 793 ... ... @@ -818,6 +818,7 @@ 818 818 819 819 To change the parameters of the cooler control algorithm, select the menu "Protections → Cooler control": 820 820 843 +[[Cooler control settings>>image:1732215313977-499.png||data-xwiki-image-style-alignment="center" height="219" width="348"]] 821 821 822 822 In this section: 823 823 ... ... @@ -850,6 +850,7 @@ 850 850 851 851 To simulate battery and BMS errors, select the menu "Protections → Fault simulation": 852 852 876 +[[Fault simulation settings>>image:1732215359330-850.png||data-xwiki-image-style-alignment="center" height="732" width="204"]] 853 853 854 854 In this section: 855 855
- 1732215174961-645.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.1 KB - Content
- 1732215211714-445.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.4 KB - Content
- 1732215252650-791.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.9 KB - Content
- 1732215282135-420.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.3 KB - Content
- 1732215313977-499.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.8 KB - Content
- 1732215359330-850.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.8 KB - Content