Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 11 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -31,7 +31,7 @@ 31 31 32 32 (% class="box infomessage" %) 33 33 ((( 34 -If there is the "Overcurrent" error, the charging and discharging relay open. 34 +If there is the "Overcurrent" error, the **charging **and **discharging **relay open. 35 35 ))) 36 36 37 37 == 3.6.2 Undervoltage protection == ... ... @@ -63,7 +63,7 @@ 63 63 64 64 (% class="box infomessage" %) 65 65 ((( 66 -If there is the "Undervoltage" error, the discharging relay opens. 66 +If there is the "Undervoltage" error, the **discharging **relay opens. 67 67 ))) 68 68 69 69 3.6.3 Overvoltage protection ... ... @@ -94,7 +94,7 @@ 94 94 95 95 (% class="box infomessage" %) 96 96 ((( 97 -If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set). 97 +If there is the "Overvoltage" error, the **charging **relay and **discharging **relay opens (if the “Switch off the discharging relay on error” flag is set). 98 98 ))) 99 99 100 100 == 3.6.4 Low temperature protection == ... ... @@ -128,8 +128,8 @@ 128 128 129 129 (% class="box infomessage" %) 130 130 ((( 131 -If there is the "Low CH temperature" error, the charging relay opens. 132 -If there is the "Low DCH temperature" error, the discharging relay opens. 131 +If there is the "Low CH temperature" error, the **charging **relay opens. 132 +If there is the "Low DCH temperature" error, the **discharging **relay opens. 133 133 ))) 134 134 135 135 == 3.6.5 High temperature protection == ... ... @@ -163,8 +163,8 @@ 163 163 164 164 (% class="box infomessage" %) 165 165 ((( 166 -If there is the "High CH temperature" error, the charging relay opens. 167 -If there is the "High DCH temperature" error, the discharging relay opens. 166 +If there is the "High CH temperature" error, the **charging **relay opens. 167 +If there is the "High DCH temperature" error, the **discharging **relay opens. 168 168 ))) 169 169 170 170 == 3.6.6 Battery cover protection == ... ... @@ -192,7 +192,7 @@ 192 192 193 193 (% class="box warningmessage" %) 194 194 ((( 195 - **If there is the "Battery cover error", the “Critical error” is generated and all relays open.**195 +If there is the "Battery cover error", the **“Critical error” **is generated and **all relays open.** 196 196 ))) 197 197 198 198 == 3.6.7 High humidity protection == ... ... @@ -254,7 +254,7 @@ 254 254 255 255 (% class="box warningmessage" %) 256 256 ((( 257 - **If there is the “Water” error, the “Critical error” is generated and all relays open.**257 +If there is the “Water” error,** **the **“Critical error”** is generated and **all relays open.** 258 258 ))) 259 259 260 260 == 3.6.9 Current sensor error == ... ... @@ -288,7 +288,7 @@ 288 288 289 289 (% class="box warningmessage" %) 290 290 ((( 291 - **If there is the “Current sensor error”, the “Critical error” is generated and all relays open.**291 +If there is the “Current sensor error”, the **“Critical error” **is generated and **all relays open.** 292 292 ))) 293 293 294 294 == 3.6.10 Short circuit protection == ... ... @@ -322,7 +322,7 @@ 322 322 323 323 (% class="box infomessage" %) 324 324 ((( 325 -If there is the "Short circuit" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 325 +If there is the "Short circuit" error, the **charging **relay opens (the “Switch off the charging relay on error” flag is set) and the **discharging **relay opens (the “Switch off the discharging relay on error flag” is set). 326 326 ))) 327 327 328 328 == 3.6.11 Contactor high temperature protection == ... ... @@ -356,7 +356,7 @@ 356 356 357 357 (% class="box infomessage" %) 358 358 ((( 359 -If there is the "Contactor high temperature" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 359 +If there is the "Contactor high temperature" error, the **charging **relay opens (the “Switch off the charging relay on error” flag is set) and the **discharging **relay opens (the “Switch off the discharging relay on error flag” is set). 360 360 ))) 361 361 362 362 == 3.6.12 Unallowable charging protection == ... ... @@ -386,7 +386,7 @@ 386 386 387 387 (% class="box infomessage" %) 388 388 ((( 389 -If there is the "Unallowable charging" error, the discharging relay opens. 389 +If there is the "Unallowable charging" error, the **discharging **relay opens. 390 390 ))) 391 391 392 392 == 3.6.13 Stuck contactor protection == ... ... @@ -410,6 +410,11 @@ 410 410 411 411 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 412 412 413 +(% class="box warningmessage" %) 414 +((( 415 +If there is the “Stuck contactor error”, the **“Critical error” **is generated and **all relays open.** 416 +))) 417 + 413 413 == 3.6.14 Contactor feedback check == 414 414 415 415 The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see section Input and output signals). ... ... @@ -429,6 +429,7 @@ 429 429 430 430 * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 431 431 437 + 432 432 == 3.6.15 Charging contactor cycles protection == 433 433 434 434 The BMS protects the charging contactor against frequent switching. ... ... @@ -459,7 +459,7 @@ 459 459 460 460 (% class="box infomessage" %) 461 461 ((( 462 -If there is the "CH contactor cycles error" error, the charging relay opens. 468 +If there is the "CH contactor cycles error" error, the **charging **relay opens. 463 463 ))) 464 464 465 465 == 3.6.16 Discharging contactor cycles protection == ... ... @@ -492,7 +492,7 @@ 492 492 493 493 (% class="box infomessage" %) 494 494 ((( 495 -If there is the "DCH contactor cycles error" error, the discharging relay opens. 501 +If there is the "DCH contactor cycles error" error, the **discharging **relay opens. 496 496 ))) 497 497 498 498 == 3.6.17 Temperature sensor error == ... ... @@ -514,7 +514,7 @@ 514 514 515 515 (% class="box warningmessage" %) 516 516 ((( 517 - **If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the “Critical error” is generated and all relays open.**523 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error” **is generated and **all relays open.** 518 518 ))) 519 519 520 520 == 3.6.18 Logic high temperature protection == ... ... @@ -542,7 +542,7 @@ 542 542 543 543 (% class="box infomessage" %) 544 544 ((( 545 - **Cell balancing is prohibited for overheated boards.**551 +Cell balancing is prohibited for overheated boards. 546 546 ))) 547 547 548 548 == 3.6.19 Logic offline protection == ... ... @@ -568,7 +568,7 @@ 568 568 569 569 (% class="box warningmessage" %) 570 570 ((( 571 - **If there is the "Logic offline" error, the “Critical error” is generated and all relays open.**577 +If there is the "Logic offline" error, the **“Critical error”** is generated and **all relays open.** 572 572 ))) 573 573 574 574 == 3.6.20 Cell count protection == ... ... @@ -575,7 +575,7 @@ 575 575 576 576 To change the protection parameters from the mismatch of the number of cells to the set value, select the menu "Protections → Cell count protection": 577 577 578 -[[C aption>>image:1732214641606-453.png||data-xwiki-image-style-alignment="center" height="178" width="341"]]584 +[[Cell count protection settings>>image:1732214641606-453.png||data-xwiki-image-style-alignment="center" height="178" width="341"]] 579 579 580 580 In this section: 581 581 ... ... @@ -597,7 +597,7 @@ 597 597 598 598 (% class="box warningmessage" %) 599 599 ((( 600 - **If there is the "Cell count error", the “Critical error” is generated and all relays open.**606 +If there is the "Cell count error",** **the **“Critical error”** is generated and **all relays open.** 601 601 ))) 602 602 603 603 == 3.6.21 Logic count protection == ... ... @@ -604,6 +604,7 @@ 604 604 605 605 To change the protection parameters from the mismatch of the number of BMS Logic boards to the set value, select the menu "Protections → Logic count protection": 606 606 613 +[[Logic count protection settings>>image:1732214675358-202.png||data-xwiki-image-style-alignment="center" height="163" width="230"]] 607 607 608 608 In this section: 609 609 ... ... @@ -624,7 +624,7 @@ 624 624 625 625 (% class="box warningmessage" %) 626 626 ((( 627 - **If there is the "Logic count error", the “Critical error” is generated and all relays open.**634 +If there is the "Logic count error", the **“Critical error” **is generated and **all relays open.** 628 628 ))) 629 629 630 630 == 3.6.22 WDT protection == ... ... @@ -633,6 +633,7 @@ 633 633 634 634 To change the parameters of the watchdog protection, select the menu "Protections → WDT protection": 635 635 643 +[[WDT protection settings>>image:1732214703914-144.png||data-xwiki-image-style-alignment="center" height="127" width="323"]] 636 636 637 637 In this section: 638 638 ... ... @@ -646,7 +646,7 @@ 646 646 647 647 (% class="box warningmessage" %) 648 648 ((( 649 - **If there is the "WDT reset" error, the “Critical error” is generated and all relays open.**657 +If there is the "WDT reset" error, the **“Critical error”** is generated and** all relays open.** 650 650 ))) 651 651 652 652 == 3.6.23 Insulation monitoring == ... ... @@ -655,6 +655,7 @@ 655 655 656 656 To change the insulation monitoring parameters, select the menu "Protections → Insulation monitoring": 657 657 666 +[[Insulation monitoring settings>>image:1732214731490-961.png||data-xwiki-image-style-alignment="center" height="162" width="315"]] 658 658 659 659 In this section: 660 660 ... ... @@ -669,6 +669,7 @@ 669 669 670 670 To change the critical error parameters, select the menu "Protections → Critical error parameters": 671 671 681 +[[Critical error parameters settings>>image:1732214761141-983.png||data-xwiki-image-style-alignment="center" height="158" width="348"]] 672 672 673 673 In this section: 674 674 ... ... @@ -702,10 +702,32 @@ 702 702 703 703 == 3.6.25 General error parameters == 704 704 715 +To change the general error parameters, select the menu "Protections → General error parameters": 716 + 717 +[[General error parameters settings>>image:1732214987517-111.png||data-xwiki-image-style-alignment="center" height="535" width="349"]] 718 + 719 +In this section: 720 + 721 +* Enable – a flag to enable the protection; 722 +* Delay before setting the error, second; 723 +* Delay before clearing the error, second; 724 +* Lock the error until the device is reset; 725 +* Errors – a section to select errors that should trigger General error. 726 + 727 +The critical error flag is generated if at least one of the selected errors is generated during the “Delay before setting the error” time. 728 + 729 +The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time. 730 + 731 +(% class="box infomessage" %) 732 +((( 733 +The "General error" is //indicative //and can be linked to any discrete output of the board. 734 +))) 735 + 705 705 == 3.6.26 Low SOC signal == 706 706 707 707 To change the parameters of the generation a signal about low battery level, select the menu "Protections → Low SOC signal": 708 708 740 +[[Low SOC signal settings>>image:1732215174961-645.png||data-xwiki-image-style-alignment="center" height="186" width="325"]] 709 709 710 710 In this section: 711 711 ... ... @@ -724,12 +724,16 @@ 724 724 725 725 * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 726 726 759 +(% class="box infomessage" %) 760 +((( 727 727 The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board. 762 +))) 728 728 729 729 == 3.6.27 High charging current signal == 730 730 731 731 To change the parameters of the generation high-current signal, select the menu "Protections → High charging current signal": 732 732 768 +[[High charging current signal settings>>image:1732215211714-445.png||data-xwiki-image-style-alignment="center" height="181" width="322"]] 733 733 734 734 In this section: 735 735 ... ... @@ -748,12 +748,16 @@ 748 748 749 749 * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 750 750 787 +(% class="box infomessage" %) 788 +((( 751 751 The "High charging current" signal is //indicative //and can be linked to any discrete output of the board. 790 +))) 752 752 753 753 == 3.6.28 Heater control == 754 754 755 755 To change the parameters of the heater control algorithm, select the menu "Protections → Heater control": 756 756 796 +[[Heater control settings>>image:1732215252650-791.png||data-xwiki-image-style-alignment="center" height="233" width="370"]] 757 757 758 758 In this section: 759 759 ... ... @@ -777,7 +777,7 @@ 777 777 778 778 (% class="box infomessage" %) 779 779 ((( 780 -If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 820 +If there is the "Heater" signal, the **heater **relay closes and/or a signal is output to the corresponded digital output. 781 781 ))) 782 782 783 783 == 3.6.29 Heater (AUX) control == ... ... @@ -784,6 +784,7 @@ 784 784 785 785 To change the parameters of the auxiliary heater control algorithm, select the menu "Protections → Heater (AUX) control": 786 786 827 +[[Heater (AUX) control settings>>image:1732215282135-420.png||data-xwiki-image-style-alignment="center" height="228" width="361"]] 787 787 788 788 In this section: 789 789 ... ... @@ -807,7 +807,7 @@ 807 807 808 808 (% class="box infomessage" %) 809 809 ((( 810 -If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output. 851 +If there is the "Heater (AUX)" signal, the **auxiliary heater **relay closes and/or a signal is output to the corresponded digital output. 811 811 ))) 812 812 813 813 == 3.6.30 Cooler control == ... ... @@ -814,6 +814,7 @@ 814 814 815 815 To change the parameters of the cooler control algorithm, select the menu "Protections → Cooler control": 816 816 858 +[[Cooler control settings>>image:1732215313977-499.png||data-xwiki-image-style-alignment="center" height="219" width="348"]] 817 817 818 818 In this section: 819 819 ... ... @@ -837,7 +837,7 @@ 837 837 838 838 (% class="box infomessage" %) 839 839 ((( 840 -If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output. 882 +If there is the "Cooler" signal, the **cooler **relay closes and/or a signal is output to the corresponded digital output. 841 841 ))) 842 842 843 843 == 3.6.31 Fault simulation == ... ... @@ -846,6 +846,7 @@ 846 846 847 847 To simulate battery and BMS errors, select the menu "Protections → Fault simulation": 848 848 891 +[[Fault simulation settings>>image:1732215359330-850.png||data-xwiki-image-style-alignment="center" height="732" width="204"]] 849 849 850 850 In this section: 851 851
- 1732214675358-202.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.1 KB - Content
- 1732214703914-144.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.6 KB - Content
- 1732214731490-961.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- 1732214761141-983.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.1 KB - Content
- 1732214987517-111.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.3 KB - Content
- 1732215174961-645.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.1 KB - Content
- 1732215211714-445.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.4 KB - Content
- 1732215252650-791.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.9 KB - Content
- 1732215282135-420.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.3 KB - Content
- 1732215313977-499.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.8 KB - Content
- 1732215359330-850.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.8 KB - Content